2. 

GENERAL OVERVIEW 

 

Congratulations on your recent purchase of your 

Oasis Aquatics SmartChem 

system.  

Please take a moment to read through the entire manual before installing your new unit. Your 

Oasis 

SmartChem 

system must be installed and operated as specified. 

While every effort has been made to ensure that the information contained in this guide is accurate and 
complete, no liability can be accepted for any errors or omissions. 

Oasis Aquatics Pty Ltd 

reserves 

the right to change the specification of the hardware and software described herein at any time without 
prior notice. 

Thank you again for choosing an Oasis Aquatics Smartchem system. We wish you many happy years 
of swimming in your crystal clear pool. 

INTRODUCTION 

The 

Oasis SmartChem 

is designed to monitor and automatically adjust the 

pH 

and Chlorine (

ORP

levels of all types of Pools & Spas while the filtration pump is running. 

Once  the 

pH 

and 

ORP 

levels  have  been  set  in  the  Oasis  Smart  App,  the 

Oasis  SmartChem 

will 

automatically dose Pool acid (when it is required) to maintain the set pH level. The 

Oasis SmartChem 

will  also  maintain  the  systems  ORP  by  either  turning  the  Chlorinator  On  or  Off,  or  by  automatically 
dosing Chlorine if you prefer Liquid Chlorine or are utilising an Ioniser. 

The 

pH

 

number is a measurement of how Acidic or Alkaline your Pool/Spa systems water is. As close 

the  7.0-

7.8  is  almost  neutral so it’s  not  harmful  to swimmers.  To much  acid (low  pH)  will  cause  the 

surface of the pool to degrade quicker. 

The 

ORP

 

is a measurement of Chlorine activity (Oxidising properties) in your Poo/Spa systems water 

and is measured in millivolts. 

It has been ascertained that a Pool system with an ORP reading of 650Mv will eliminate E-coli type 
bacteria in about a second. The lower the ORP reading, the longer it will take for the bacteria to be 
eliminated from the system. An ORP reading of 550Mv will mean that it could take up to 2hrs for the 
bacteria to be eliminated. 

IMPORTANT 

THE 

OASIS SMARTCHEM 

IS NOT DESIGNED TO BRING THE POOL/SPA SYSTEM INTO 

BALANCE; IT IS DESIGNED TO MAINTAIN A BALANCED SYSTEM. 

Make sure your pool water is well balanced with the correct pH, Total Dissolved Solids (TDS), Calcium 
Hardness levels and is Phosphate free. 

 

 

Summary of Contents for SmartChem

Page 1: ......

Page 2: ...2 GENERAL OVERVIEW 3 3 INSTALLATION 4 Mounting 4 Installation Diagram 4 Base Plate 6 Controller Connection 8 App Setup 9 4 ANCILLARY INSTRUCTIONS 13 Maintenance Schedule 13 Probe Cleaning 14 Replacin...

Page 3: ...L CALCIUM HARDNESS 90 300 mg L PHOSPHATE FREE 0 TOTAL DISOLVED SOLIDS Below 1500ppm Always take a sample of your pool water away from the return jets to ensure as accurate reading as possible Always s...

Page 4: ...m will automatically dose Pool acid when it is required to maintain the set pH level The Oasis SmartChem will also maintain the systems ORP by either turning the Chlorinator On or Off or by automatica...

Page 5: ...red if installing into 40mm pipe for the sensors to mount into the centre of the inputs will be drilled out to accommodate the sensor probes A power cable providing power to the Oasis SmartChem from a...

Page 6: ...or a period of time to ensure the glue used to connect the manifolds has had the appropriate time to dry and bond properly to achieve correct pressure rating The Sensor Injection Manifolds suit 50mm p...

Page 7: ...Soak the ends of supply and injection hoses in hot water for 30 seconds to soften them this will make it easier when fitting the tubes to the pump barbs The lid kit has been installed into the bottle...

Page 8: ...piping from the breather port on the lid to outside of the shed or shelter A through shed connection is supplied to prevent a build up of fumes inside the shed shelter ENSURE THAT THE OASIS SMART CON...

Page 9: ...to be utilised through the App go to page 7 Of this guide and you can exit the menu by pressing the Menu button or if you need to reset the Oasis SmartChem unit press Enter and see below for further i...

Page 10: ...first going into the Chemical Setup menu option first Chemical Setup When you go into the Chemical Setup option in the menu you will see this display The first thing that you will need to do is tell t...

Page 11: ...problem with the pump you are changing over the acid bottle tub or if you have run out of Acid The same functionality applies to the ORP Sensor The Offset will allow you to adjust the reading of the p...

Page 12: ...nd count to let you know how much time is left for the priming cycle The following is displayed on the App Home Screen There is only a limited amount of information displayed in regards to the Chemica...

Page 13: ...is displaying CHECK you will need to take a sample of your pool water to your local pool shop and get it tested and add the amount of Acid or Buffer required to get the pH level back to where it needs...

Page 14: ...page 8 of this manual Check all tubes fittings and connections to ensure no leaks Check the squeeze tube in the Peristaltic pump to ensure that it isn t leaking replace if doing so Apply a silicon lu...

Page 15: ...uted on a soft cloth Clean the pH membrane rinse with water and condition in 20 KCl before use In the case of protein contamination use 5 Pepsin in 0 1M HCl solution HINT Calibrate the pH probe regula...

Page 16: ...gently but firmly lift the cover The head cover will come off to expose the squeeze tube and the head The pump head can be pulled out the squeeze tube will come with it and a new squeeze tube can be...

Page 17: ...rectly Clean and or Re calibrate probe or adjust probe Offset as per pg 8 pH Set Point is set to High Adjust pH Set Point to appropriate level 7 2 7 8 Manual Overdosing of Chlorine Shock Treatment Mai...

Page 18: ...ppropriate level 30 50mg L As per above Note The need to run Stabiliser in an outdoor pool may be reduced if your Chlorinator is sufficiently sized to produce enough chlorine to negate the use of Stab...

Page 19: ...Oasis SmartChem INSTALLATION AND OPERATION MANUAL Page 18 of 22...

Page 20: ...c to 14 strongly alkaline but any reading outside of the 5 5 to 8 5 range will only be displayed in the Chemical Setup option of the menu ORP readings on the home screen of the Oasis Smart App will on...

Page 21: ...e interval of time for the added chemicals to properly mix throughout the pool system Continue testing and adding chemicals until the pool system becomes balanced o If you add large quantities of chem...

Page 22: ...breach of a condition or warranty shall be limited to replacing or acquiring the equipment or part thereof where the same has been supplied The maximum liability incurred by the manufacturer shall no...

Page 23: ...subject s Its use is beyond the control of the author contributor publishers and distributors and should not be relied upon without consulting your local Professional for comprehensive advice This gui...

Page 24: ...Oasis SmartChem INSTALLATION AND OPERATION MANUAL Page 23 of 22 9 NOTES...

Page 25: ...eld VIC 3180 Australia T 03 9887 2131 New South Wales Unit 2 10 Boden Road Seven Hills NSW 2147 Australia T 02 9838 0000 Queensland Unit 4 8 Reichert Drive Molendinar QLD 4214 Australia T 07 5679 6821...

Reviews: