- EN -
22
Addressing via DMX/RDM
RDM (Remote Device Management) is an open and bi
-directional protocol standard for DMX-controlled devices. The
permanently transmitted DMX data flow briefly pauses (several milliseco
nds), and an RDM data package (message) is
sent directly to a subscriber. The subscriber evaluates the information in the data package and sends an answer (semi-
duplex) on the same line. Targeted polling to a subscriber via its UID (Unique ID) prevents sev
eral subscribers from
answering simultaneously.
The protocol makes it possible to receive status information about a unit or to change configurations on a unit. Chang-
ing the configuration means, e.g. changing the DMX address. The prerequisite for this function is a RDM-compatible
controller. Read the corresponding operating instructions
RDM parameters
General parameters
GET
CMD
SET
CMD
Description
COMMS_STATUS
•
Shows general status information of the bus interface
STATUS_MESSAGES
•
Used to manage status messages
STATUS_ID_DESCRIPTION
•
Used to manage status messages
SUPPORTED_PARAMETERS
•
Overview of all RDM parameters
PARAMETER_DESCRIPTION
•
Description of all parameters
DEVICE_INFO
•
Brief overview of the most important features
PRODUCT_DETAIL_ID_LIST
•
Additional feature
DEVICE_MODEL_DESCRIPTION
•
Type designation
MANUFACTURER_LABEL
•
Manufacturer's designation
DEVICE_LABEL
•
•
Labelling field
SOFTWARE_VERSION_LABEL
•
Firmware version number
DMX_START_ADDRESS
•
•
Reading and setting the DMX start address
SENSOR_DEFINITION
•
Sensor information
SENSOR_VALUE
•
Sensor value
Sensor 1
TempLpErrorCount
Temperature error counter, PCB
Sensor 2
TempWindErrorCount
Temperature error counter, motor
Sensor 3
MotorFailureCount
Motor failure counter
Sensor 4
ActualSpeed
Current actual speed
Sensor 5
NominalSpeed
Current set point speed
Sensor 6
PWM
Current PWM value
Sensor 7
Temp
Operating temperature, electronic board
Sensor 8
Winding Temp
Operating temperature, motor
Sensor 9
Power Voltage
Current intermediate circuit voltage
Sensor 10
Current Consumption
Current intermediate circuit current
DEVICE_HOURS
•
Operating hour counter
DEVICE_POWER_CYCLES
•
Switch-on counter
IDENTIFY_DEVICE
•
•
0 = normal mode
1 = pump will switch on and off again at short intervals. This function is helpful for
identifying the device in the field.
RESET_DEVICE
•
Executes a reset.
1 = warm start
255 = cold start
Specific parameters
GET
CMD
SET
CMD
Description
KENNLINIENPUNKT_X1
•
•
Support value 1 of the stored pump characteristic curve
KENNLINIENPUNKT_Y1
•
•
KENNLINIENPUNKT_X2
•
•
Support value 2 of the stored pump characteristic curve
KENNLINIENPUNKT_Y2
•
•
KENNLINIENPUNKT_X3
•
•
Support value 3 of the stored pump characteristic curve
KENNLINIENPUNKT_Y3
•
•
RUNTIME_HOURS
•
Operating hour counter for the running period
STARTUP_COUNTER
•
Startup counter
CONFIG_MODE
•
•
Only for service purposes
STS_OVERTEMP
•
Status message, overtemperature
STS_OVERVOLTAGE_PHASE
•
Status message, overvoltage
STS_UNDERVOLTAGE_PHASE
•
Status message, undervoltage
STS_OVERCURRENT
•
Status message, operating voltage too high
STS_BLOCKIERT
•
Status message, motor blocked
Summary of Contents for Varionaut 270 DMX/02
Page 2: ...2 A VNT0036 B VNT0037 C VNT0038...
Page 3: ...3 D VNT0039...
Page 4: ...4 E VNT0040...
Page 5: ...5 F VNT0042...
Page 6: ...6 G PLX0004 H VNT0041...
Page 7: ...7 I VNT0043...
Page 44: ...44 Varionaut 270 DMX 02 VNT0045 Varionaut 400 DMX 02 VNT0051...
Page 46: ...46 VNT0035...
Page 47: ...47 VNT0050...
Page 48: ...44995 11 19...