background image

Cleanfilter

How to proceed:

E

1. Switch off the pump.

2. Disconnect the power plug.

3. Close all shut-off devices on the suction

side if applicable.

4. Unscrew the cover of the filter chamber

and remove.

5. Pull out the filter cartridge.

6. Clean the filter cartridge and filter cover

under running water using a brush.

7. Reassemble the filter in the reverse or-

der.
– Ensure that the filter cover seal is in

place and undamaged. Otherwise re-
place it.

– Ensure that the filter cover is correctly

screwed on.

8. Reassemble the unit in the reverse or-

der.

STORAGE/OVERWINTERING

The unit is not frost-proof and has to be
removed and put into storage if minus
temperatures are expected.
How to correctly store the unit:
• Drain the unit as far as possible, clean

thoroughly and check for damage.

• Empty all hoses, pipes and connections

as far as possible.

• Thoroughly clean the unit, check it for

damage and replace any damaged
parts.

• Store the unit in a dry and frost-free

place.

• Protect open plug connections from

moisture and dirt.

WEAR PARTS

The following components are wear parts
and are excluded from the warranty:
• Filter cartridge.
• Impeller

DISPOSAL

N O T E

Do not dispose of this unit with domestic
waste.
• Render the unit unusable beforehand

by cutting the cables and dispose of the
unit via the return system provided for
this purpose.

Summary of Contents for ProMax Garden Automatic 3500

Page 1: ...P roMaxG ardenA utom atic3500 4000 5000 6000 5 43921_Oase_GA_ProMax_GardenAutomatic 3500 6000_DE_A5_1015 indd 1 13 10 15 14 18 Ihr Pumpen Experte...

Page 2: ...2 ProMax Garden Automatic 3500 4000 5000 6000 A POX0032 B C POX0026 POX0027 D POX0043...

Page 3: ...3 E POX0028...

Page 4: ...liche Situation Bei Nichtbeachtung kann Tod oder schwerste Verletzung die Folge sein H I N W E I S Informationen die zum besseren Ver st ndnis dienen Weitere Hinweise A Verweis auf eine Abbildung z B...

Page 5: ...durchge f hrt werden Elektrischer Anschluss Das Ger t muss ber eine Feh lerstrom Schutzeinrichtung mit einem Bemessungsfehlerstrom von maximal 30 mA abgesi chert sein Schlie en Sie das Ger t nur an we...

Page 6: ...ss zum Entleeren der Pumpe ein entsprechend gro es Auffanggef unter die Ablass Schraube gebracht werden kann Pumpe nach M glichkeit h her aufstel len als das Wasserreservoir aus dem gepumpt werden sol...

Page 7: ...drehen und Restwasser durch Neigen der Pumpe herausflie en lassen 7 Wasserablass Schraube wieder eindre hen BEDIENUNG POX0041 1 LED blau 2 LED gelb 3 LED rot 4 Ein Aus Taste W hrend des Betriebs berwa...

Page 8: ...mpe betriebsbereit Pumpe einschal ten Fehlerfrei Pumpe l uft 4 Sekunde Fehlerfrei Pumpe wechselt gleich in Stand by Fehlerfrei Pumpe ist im Stand by Pumpe saugt kein Wasser 1 Stufe Trockenlaufschutz W...

Page 9: ...ers oder dem Hineinfassen die Netzspannung aller im Wasser befindlichen Ger te abschalten Nach Abschluss der Arbeiten Alle Voraussetzungen f r die Inbetriebnahme wieder herstellen St rung Ursache Abhi...

Page 10: ...g und Saug abgeschaltet leitung reinigen Saugseitige Verstopfung Ansaug ffnung und Saug leitung reinigen R ckschlagventil defekt OASE Service kontak tieren REINIGUNG UND WARTUNG W A R N U N G Gef hrli...

Page 11: ...ng vorhanden und unbesch digt ist Andernfalls ersetzen Darauf achten dass der Filterdeckel wieder ordnungsgem aufge schraubt ist 8 Ger t in umgekehrter Reihenfolge zu sammenbauen LAGERN BERWINTERN Das...

Page 12: ...ewinde mm G1 G1 G1 G1 Druck bar 4 4 5 5 5 8 Zul ssiger Innendruck maximal bar 6 6 6 6 F rdermenge maximal l h 3500 4000 4700 5800 F rderh he maximal m 40 45 50 58 Ansaugh he maximal m 8 8 8 8 Pumpenla...

Page 13: ...n Non observance may lead to death or serious injuries N O T E Indicates information intended to give the user a better understanding Additional information A Reference to a figure e g Fig A Reference...

Page 14: ...ical data of the unit and the power supply coincide The unit data is to be found on the unit type plate on the packaging or in this manual Extension cables and power distributors e g outlet strips mus...

Page 15: ...n stake to relieve the weight of the hose on the pump B Screw a suction and pressure hose with 25 0 mm internal diameter 1 onto the connections OPERATION Start up of the device It is necessary to fill...

Page 16: ...e oper ating state stand by or switches off The lit or flashing LEDs in the ON OFF button indicate the respective operating status Operating status and atten dant LED displays Operating modes Mode A d...

Page 17: ...ge dry run pro tection Wait 2 per second Pump is not taking in water 3rd stage dry run pro tection In the 4th stage the pump switches into waiting mode Wait 3 per sec ond each LED alter nately 4th sta...

Page 18: ...is switched off Switch on the pump Power supply interrupted Check the electrical plug connections The fault current protection de vice has tripped Switch off the pump and disconnect the power plug The...

Page 19: ...or severe injury from electrocu tion Prior to starting work Switch off the unit disconnect the power plug and secure the unit from being switched on again Before stepping into or reaching into the wat...

Page 20: ...NG The unit is not frost proof and has to be removed and put into storage if minus temperatures are expected How to correctly store the unit Drain the unit as far as possible clean thoroughly and chec...

Page 21: ...ion suction pressure side internal thread mm G1 G1 G1 G1 Pressure bar 4 4 5 5 5 8 Permissible internal pressure Max bar 6 6 6 6 Flow rate Max l h 3500 4000 4700 5800 Head height Max m 40 45 50 58 Suct...

Page 22: ......

Reviews: