- EN -
48
5.4
Connecting an EGC-compatible device
The correct fastening of the plug connector is important for a secure connection and an interference-free EGC
network.
An EGC connection cable is necessary for connection.
The EGC connection cable is available as an accessory in the lengths 2.5 m (47038), 5 m (47039) and 10 m
(47040).
How to proceed:
G, H
1. Remove the terminal resistor from the unit.
2. Fit the plug connector and secure with the two screws (max. 2.0 Nm).
Ensure that the rubber seal is clean and fits exactly.
Replace the rubber seal if damaged.
3. Remove the protection cap from EGC-OUT of the last unit in the EGC network, fit the terminal resistor and
secure it with the two screws (max. 2.0 Nm).
No EGC connection cable is connected to EGC-OUT on the last unit in the EGC network. The terminal re-
sistor has to be fitted to this EGC-OUT so that the EGC network is correctly terminated.
The terminal resistor is included in the delivery scope of the InScenio FM-Master WLAN EGC.
N O T E
For further information regarding the operation and integration into the EGC system, please refer to
the instructions for use of the FM Master WLAN EGC at
http://www.oase-livingwater.com/egc-start
5.5
Connect the units to the power supply distributor
Only connect one unit per socket.
Do not connect any InScenio controllers or portable multiple sockets to the unit.
1 Socket 1, switchable (max. 10 A / 2000 W)
2 Socket 2, switchable (max. 10 A / 2000 W)
3 Socket 3, switchable (max. 10 A / 2000 W)
4 Socket 4, switchable and dimmable (40 W … 320 W)
Note:
Ensure that the total output of 16 A / 3600 W is not exceeded!
How to proceed:
1. Choose a suitable socket (see fig. above) and insert the unit power plug into the socket.
Ensure that it is permissible to connect the unit to this socket. For this purpose, consult the operating man-
ual of the unit you wish to connect.
Units powered via a transformer may not be connected to the socket with the dimmer function.
EGC-capable units may not be connected to the socket with the dimmer function.
I
2. Fit the protection hood.
Summary of Contents for FM-Master WLAN
Page 1: ...FM Master WLAN FM Master WLAN EGC ...
Page 2: ... 2 A FMR0026 B FMR0003 C D FMR0028 FMR0027 F ...
Page 3: ... 3 E F FMR0005 FMR0029 G FMR0031 H EGC0003 ...
Page 4: ... 4 I FMR0008 J K FMR0030 FMR0007 ...
Page 799: ... CN 799 默认设置 控制器重置为默认设置 所有个性化设置值都将被覆盖 如下值将被设置 清洗时间 CL 10 秒 延长清洗时间 EC 20 秒 时间关联的清洗间隔 In 20 分钟 ...
Page 822: ...40216 05 17 V2 0 ...