Exchange the UVC lamp
CAUTION
The ultra-violet radiation of the UVC lamp can burn your eyes and skin.
Never operate the UVC lamp outside its housing.
Disconnect the unit from the mains before starting maintenance or before
replacing the UVC lamp.
CAUTION
The quartz glass and UVC lamp could break and result in cuts.
Carry out all work on the UVC clarifier carefully to avoid cutting injuries.
Avoid vibrations, impacts and hectic movements to prevent the breaking of glass.
For safety reasons, the UVC lamp can only be turned on when the UVC clarifier is
properly installed into the device.
For optimum filter performance, replace the UVC lamp after approx. 8000 oper-
ating hours.
•
Only use UVC lamps that correspond with the technical data of the device.
(
•
Make sure that the O-ring on the quartz glass is positioned between the union nut
and the thread on the UVC clarifier so that the quartz glass is watertight.
•
Tighten the union nut clockwise until it stops and fix the union nut with the lock-
ing screw.
•
Check that the large O-ring is correctly inserted in the water housing. This ensures
that the water housing is watertight.
•
During installation, rotate the device head clockwise until the marking points to
the locked lock.