Installing the UVC unit head
FCL0017
Replacing the UVC lamp
The UVC lamp is a wear part. Replace the UVC lamp when the indicated operating hours have
been reached. This ensures optimum filtering performance.
Prerequisite:
•
The UVC unit head has been removed. (
•
Only use UVC lamps, the identification and power data of which correspond to the information
on the type plate. (
How to proceed:
•
Removal: Turn the bayonet ring all the way to the “lock open” position to remove the holding
plate and the UVC lamp.
•
Installation: Turn the bayonet ring all the way to the “lock closed” position. Otherwise you
cannot install the UVC unit head.
–
On delivery, the bulb of the UVC lamp is protected by a transport guard. The lamp guard is
not required for the lamp function and does not need to be reinstalled.
If necessary remove a lamp guard stuck in the quartz glass as follows:
−
Remove the quartz glass. (
Cleaning/replacing the quartz glass)
−
Carefully and steadily knock the rotor lid with the quartz glass against a firm surface. The
lamp guard will slowly slide out of the quartz glass.
OSRAM UVC lamps can only be installed without the holding plate. OASE therefore recom-
mends using Philips UVC lamps.
FiltoClear
UVC lamp power
Replace UVC lamp after
3400
24 W
8000 h (one pond season)
5200
42 W (optionally 36 W)
42 W / 60 W: 12000 h
36 W / 55 W: 8000 h
8200
60 W (optionally 55 W)
Summary of Contents for FiltoClear 3400
Page 6: ...6 Product description Overview FCL0007...
Page 35: ...FR 35 Description du produit Vue d ensemble FCL0007...
Page 64: ...64 Descripci n del producto Vista sumaria FCL0007...
Page 89: ...89 XX FCL0035...
Page 90: ...90 FCL0036...
Page 91: ...91 FCL0037...
Page 92: ...92 FCL0031...
Page 93: ...93 FCL0032...
Page 94: ...94 FCL0033...
Page 95: ...95 FCL0034...