Information about these operating instructions 

 

Welcome to OASE Living Water. You made a good choice with the purchase of this product 

Eco Control

Prior to commissioning the unit, please read the instructions of use carefully and fully familiarise yourself with the unit. 

Ensure that all work on and with this unit is only carried out in accordance with these instructions. 

Adhere to the safety information for the correct and safe use of the unit. 

Keep these instructions in a safe place! Please also hand over the instructions when passing the unit on to a new 

owner. 

 

 

 

Symbols used in these instructions 

 

The warning information is categorised by signal words, which indicate the extent of the hazard. 

 

 

 

 

W A R N I N G  

  Indicates a possibly hazardous situation. 

  Non-observance may lead to death or serious injuries. 

 

 

 

 

N O T E  

Information for the purpose of clarification or for preventing possible damage to assets or to the environment. 

 

 

 

Scope of delivery 

 

 A 

Description 

AquaMax Eco Control 

Retaining frame for fastening the device to the wall, or for fitting it to the ground stake or holding clip 

Ground stake 

Holding clip for fastening the device to the pump handle 

 

 

 

 

Product Description 

 

Eco Control can be used to control EGC-capable OASE pumps. 

Features: 

  Connection to the EGC socket of the pump. 

  Illuminated display. 

  Does not require a separate power supply. 

  Control of the pump capacity, switching the Seasonal Function Control (SFC) and Dynamic Function Control (DFC) 

on or off, selection of programmes. 

  Allows display of the pump status and malfunctions. 

 

 

 

Intended use 

 

Eco Control, referred to as "unit", may only be used as specified in the following: 

 

  Connection to OASE pumps with EGC connection, that are suitable for control via this device. 

 

  Operation under observance of the technical data. 

 

 

 

Installation and connection 

 

Fastening the device to the pump 

How to proceed: 

 

 B 

 

1. Fit the holding clip onto the pump handle. 

2. Slide the device onto the holding clip. 

3. Align the device. 

 

 

 

Installing the device with the ground stake 

How to proceed: 

 

 C 

 

1. Fully insert the ground stake into the ground. 

2. Slide the device onto the ground stake. 

3. Check its stability. 

 

 

 

Downloaded from http://www.watergardeningdirect.com

Summary of Contents for Eco Control

Page 1: ...48626 09 16 Eco Control 48626 GA_Eco Control_A5_end_ 21 09 16 11 21 Seite 2 Downloaded from http www watergardeningdirect com...

Page 2: ...2 A AMX0029 B C AMX0031 AMX0032 D AMX0030 E AMX0035 Downloaded from http www watergardeningdirect com...

Page 3: ...ale Wassertemperatur von 35 C einhalten WARNING HIGH POWER Stromaufnahme zu hoch Laufeinheit schwerg ngig Starke Wasserverschmutzung Pumpe reinigen Lagern berwintern Das Ger t ist frostsicher bis 20 C...

Page 4: ...o judge and carry out the work commissioned to him her This also includes the recognition of possible hazards and the adherence to the pertinent regional and national standards rules and regula tions...

Page 5: ...ng frame for fastening the device to the wall or for fitting it to the ground stake or holding clip 3 Ground stake 4 Holding clip for fastening the device to the pump handle Product Description Eco Co...

Page 6: ...t the plug to the left hand EGC socket N O T E The device will be destroyed if water penetrates the EGC sockets Close the EGC sockets with EGC plugs or a protection cap Operation Control system overvi...

Page 7: ...he speed is shown as a percentage SFC is deactivated SFC MODE SFC is activated it is not possible to adjust the speed SFC mode MIN MID MAX Adjustment only for SPEED Change the speed using the arrow ke...

Page 8: ...US 28000 DFC MODE SCENE 1 DFC MODE OFF DFC MODE SCENE 1 Only display DFC Seasonal Flow Control ON Activated OFF Deactivated DFC MODE SCENE 1 SCENE 12 DFC deactivated No display Select the next display...

Page 9: ...Note maximum water temperature of 35 C WARNING HIGH POWER Current consumption too high Impeller unit running sluggishly Excessively soiled water Clean the pump Storage overwintering The unit is frost...

Page 10: ...dning Dimensioner V gt NO Tekniske data Tilkobling grensesnitt Lengde stikkledninger M l Vekt SV Tekniska data Anslutning gr nssnitt L ngd anslutningsledning M tt Vikt FI Tekniset tiedot Liit nt Liit...

Page 11: ...e kast i alminnelig husholdningsavfall NB Les bruksanvisningen SV Dammskyddad Skyddad mot droppvatten Skydda mot direkt solstr l ning F r inte kastas i hush llsso porna Varning L s igenom bruksanvisni...

Page 12: ...48626 10 16 Downloaded from http www watergardeningdirect com...

Reviews: