- EN -
9
Installation
Aquarius Solar can be installed in two versions (A+B), unit with filter wings attached, or with filter wings removed. Fit
the water feature hose to connection (A3) which can be regulated, and the OASE spotlight to connection (A4).
Maintenance and cleaning
Attention! Dangerous electrical voltage.
Possible consequences:
Death or severe injury.
Protective measures:
Electrical units and installations with a rated voltage of U > 12 V AC or U >30 V DC located in the water:
Isolate the units and installations (switch off and disconnect from the power supply) before reaching into
the water.
Isolate the unit before starting any work.
Secure the unit to prevent unintentional switching on.
Cleaning the unit
Note!
Recommendation on regular cleaning:
Clean the pump as required but at least twice a year.
Never use aggressive cleaning agents or chemical solutions. These could attack the housing surface or impair the
function.
Recommended cleaning agent for removing stubborn limescale deposits:
– Pump cleaning agent PumpClean from OASE.
– Vinegar- and chlorine-free household cleaning agent.
After cleaning, thoroughly rinse all parts in clean water.
Malfunctions
Trouble shooting
Cause
Remedy
Unit does not run
- no voltage, 12 Volt
- Rotor blocked
- Sun energy insufficient
- Check voltage source
- Clean pump
Fountain height insufficient or
inconsistent
- Main flow regulator closed too far
- Nozzle blocked
- Filter/screen clogged
- Rotor soiled
- Hose blocked or defective
- Hose kinked
- Excessive loss due to friction in the hose
- Rotor worn
- Sun energy insufficient
- Adjust main flow regulator
- Clean nozzle
- Clean filter/screen
- Clean rotor
- Clean hose or replace
- Check hose and replace if necessary
- Reduce hose length to reduce frictional loss
- Replace rotor
Disposal
Do not dispose of this unit with domestic waste! For disposal purposes, please use the return system provided.
Disable the unit beforehand by cutting off the cables.
Storage/Over-wintering
Remove the unit at temperatures below zero degrees centigrade. Thoroughly clean and check the unit for damage.
Store the unit immersed in water or filled with water in a frost-free place. Do not flood the power plug!
Repair
A damaged unit cannot be repaired and must be put out of operation. Dispose of the unit in accordance with the regu-
lations.
Wear parts
The impeller unit is a wearing part and does not fall under the warranty.
Summary of Contents for Aquarius Solar 700
Page 1: ...14405 08 15 Aquarius Solar 700 1500 14405 GA Aquarius Solar_A5_end_ 25 08 15 15 47 Seite 2...
Page 3: ...3...
Page 58: ...BG 58 BG OASE Living Water Aquarius Solar 700 1500 BG Aquarius Solar 700 1500 12 V DC 8...
Page 59: ...BG 59 ICD 20 OASE Solarsafe OASE A B Solarsafe 12 V...
Page 60: ...BG 60 Aquarius Solar A B A3 OASE A4 U 12 V AC U 30 V DC 2 PumpClean OASE 12 V...
Page 61: ...UK 61 UK OASE Living Water Aquarius Solar 700 1500 UA Aquarius Solar 700 1500 12 8...
Page 62: ...UK 62 ICD 20 OASE Solarsafe OASE A B Solarsafe 12...
Page 63: ...UK 63 Aquarius Solar A B 3 OASE 4 U 12 U 30 2 PumpClean OASE 12...
Page 64: ...RU 64 RU OASE Living Water Aquarius Solar 700 1500 RU Aquarius Solar 700 1500 12 8...
Page 65: ...RU 65 ICD 20 Solarsafe OASE OASE Solarsafe 12...
Page 66: ...RU 66 Aquarius Solar A B A3 OASE A4 U 12 U 30 2 PumpClean OASE 12...
Page 67: ...CN 67 CN OASE Living Water Aquarius Solar 700 1500 D Aquarius Solar 700 1500 12 8...
Page 68: ...CN 68 ICD 20 OASE Solarsafe A B Solarmodule Solarsafe 12...
Page 69: ...CN 69 Aquarius Solar A B A3 A4 U 12 V U 30 V 2 OASE PumpClean 12...
Page 72: ...700 1500 14405 09 15...