Installation 

 

Installation requires pipes with the following nominal widths (pipe diameters): 

  AquaMax Eco Titanium 30000: DN 63 

  AquaMax Eco Titanium 50000: DN 75 

 

 

 

Fitting connections 

 

Fit the appropriate pipe to the inlet and outlet. 

 

 

 

AquaMax Eco Titanium 30000 

How to proceed: 

 

 K 

 

1. Remove the protection cap. 

 

2. For submerged installation, protect the pump inlet against unforeseeable reaching in: 

–  Screw a contact guard (accessory, article No. 48597) onto the inlet or 

–  protect the pump chamber against unauthorised access (use a padlock or screws to secure the access). 

 

3. Connecting the pipes (DN 63) 

–  The position of the pump outlet can be changed. The pump casing can be turned to achieve a different position.  

 

 

 

AquaMax Eco Titanium 50000 

How to proceed: 

 

 L 

 

1. Remove the protection cap. 

 

2. For submerged installation, protect the pump inlet against unforeseeable reaching in: 

–  Screw a contact guard (accessory, article No. 43329) onto the inlet or 

–  protect the pump chamber against unauthorised access (use a padlock or screws to secure the access). 

 

3. Connecting the pipes (DN 75) 

–  The position of the pump outlet can be changed. The pump casing can be turned to achieve a different position.  

 

 

 

Turning the pump casing to achieve a different position  

 

If necessary, the pump casing can be turned to change the position of the pump outlet by 90°. 

 

 

 

AquaMax Eco Titanium 30000 

How to proceed: 

 

 M 

 

1. Remove both screws from the EGC box on the pump base in order to hinge the box to the side. 

2. Undo the screw at the pump base but do not unscrew it completely, then pull off the pump. 

3. Remove the four screws and take off the pump casing. 

4. Turn the pump casing counterclockwise through 90°, fit it onto the motor and fasten with four screws. 

–  The pump casing can only be mounted in the two positions indicated. 

5. Push the pump onto the pump base and tighten the screw. 

6. Hinge the EGC box underneath the pump base and fasten with both screws. 

 

 

 

AquaMax Eco Titanium 50000 

How to proceed: 

 

 N 

 

1. Remove the screws and remove the pump from the stand. 

 

2. Remove the four screws and take off the pump casing. 

 

3. Turn the pump casing, place it onto the motor and fasten with the four screws. 

 

4. Place the pump on the stand and fasten with the screws. 

 

Summary of Contents for AquaMax Eco Titanium 30000

Page 1: ...46965 10 16 AquaMax Eco Titanium 30000 50000 46965_GA_AquaMax_Eco_Titanium_30000 50000_A5_end_ 18 10 16 17 16 Seite 2...

Page 2: ...2 A B AMX0050 AMX0045 C AMX0029 D E AMX0049 AMX0038...

Page 3: ...3 F G AMX0055 AMX0056 H AMX0037 I AMX0042...

Page 4: ...4 J AMX0051 K AMX0040...

Page 5: ...5 L AMX0052...

Page 6: ...6 M AMX0043...

Page 7: ...7 N PLX0004 O FMR0031...

Page 8: ...8 P AMX0053...

Page 9: ...9 Q AMX0041...

Page 10: ...2 V AC or 30 V DC from the power supply Only operate the unit if no persons are in the water A damaged connection cable cannot be replaced Dispose of the unit Safety information Electrical connection...

Page 11: ...ised customer service point or when in doubt the manufacturer Only use original spare parts and accessories for the unit Never carry out technical modifications to the unit Keep the socket and power p...

Page 12: ...er observance of the permissible water quality Water quality The following restrictions apply to the unit Do not use in swimming ponds Never use the unit to convey fluids other than water Never run th...

Page 13: ...the pump is only permitted with observance of the specified water quality Water quality Pool water or salt water can impair the appearance of the unit Such impairments are excluded from the guarantee...

Page 14: ...n it Eco Control Eco Control has two possibilities for fastening Fastening to the pump Fastening to the wall or installation on the ground Operating instructions Eco Control AquaMax Eco Titanium 30000...

Page 15: ...or screws to secure the access 3 Connecting the pipes DN 75 The position of the pump outlet can be changed The pump casing can be turned to achieve a different position Turning the pump casing to ach...

Page 16: ...0 Nm or another EGC compatible unit No Connection Cable EGC is connected to EGC OUT on the last unit in the EGC network The terminal resistor has to be fitted to this EGC OUT so that the EGC network...

Page 17: ...locked Disconnect the power supply and remove obstacle Then switch the pump on again Pump has run dry Flood the pump Fully submerge the pump for operation in the pond Maintenance and cleaning W A R N...

Page 18: ...C box on the pump base in order to hinge the box to the side 2 Undo the screw at the base of the pump but do not unscrew it completely then pull off the pump 3 Remove the four screws and take off the...

Page 19: ...ir is not possible in the following cases The pump has to be replaced If there is no replacement part approved by OASE for a defective component If an electric cable permanently connected to the pump...

Page 20: ...SV Anslutningssp nning Effekt ing ng utg ng Kabell ngd M tt Vikt FI Verkkoj nnite Ottoteho Sis ntulo Ulostulo Kaapelin pituus Mitat Paino HU Csatlakoztat si fesz lts g Teljes tm nyfelv tel bemenet kim...

Page 21: ...raffreddamento forzato Portata Colonna d acqua Profondit d immer sione DA Neds nket opstilling Tilladt vandtemperaturomr de T r opstilling Maks tilladt omgivelsestemperatur ved naturlig konvektion T r...

Page 22: ...temperatura pri prirodnoj konvekciji Postavljanje na suho mjesto Maks dopu tena okolna temperatura pri prisilnom hla enju Proto ni kapacitet Vodeni stup Dubina uranjanja RO Instalare scufundat Domeniu...

Page 23: ...Temperatur SE Rekommenderade vattenv r den ph v rde Total h rdhet Fritt klor Kloridhalt Salthalt Temperatur FI Suositellut vesiarvot ph arvo Kokonaiskovuus Vapaa kloori Kloridipitoisuus Suolapitoisuu...

Page 24: ...tt ned til 4 m dyp Beskytt mot direkte sollys Ikke kast i alminnelig husholdningsavfall NB Les bruksanvisningen SV Dammt t Vattent t till 4 m djup Skydda mot direkt solstr lning F r inte kastas i hush...

Page 25: ...235 AquaMax Eco Titanium 30000 AMX0057 AMX0058...

Page 26: ...236 AquaMax Eco Titanium 50000 AMX0059 AMX0060...

Page 27: ...46965 12 16...

Reviews: