Installation and connection
The pump can be installed submerged (in water) or dry (outside the water).
The use of the pump is only permitted with observance of the specified water quality.
•
Pool water or salt water can impair the appearance of the unit. Such impairments are excluded
from the guarantee.
WARNING
The power supply carries dangerous electrical voltage and must not be placed directly near wa-
ter. Otherwise, there is a risk of serious injury or death from electric shock.
Install the power supply in a flood-protected position at least 2 m from the water.
CAUTION
Rotating components in the intake and pressure socket area. Risk of injury when reaching into
the sockets.
In particular, observe the following:
A unit that has stopped due to overload can start up unex-
pectedly!
Do not reach into the opening of the intake socket or pressure socket while the power plug is
plugged in.
If the sockets are freely accessible during operation, e.g. if no hoses are connected, use a hand
guard to secure the sockets. The hand guard is available as an accessory.
Avoid exposing any unit components to direct sunlight for extended periods of time, as this
can lead to damage. If necessary, use a protective cover.
Submerged installation of the pump
Connecting
Connect the pump according to the desired installation variant. (
B
•
Ensure that the intake-side hose (IN) does not have a smaller diameter than the pressure-side
hose (OUT).
•
The larger the hose diameter, the smaller the friction losses in the lines and the better the
flow rate.
•
The hose diameter must not be limited unnecessarily by a hose sleeve. Shorten the hose
sleeve based on the hose diameter, if necessary.
Do not plug the power plug into the socket yet!
Summary of Contents for AquaMax Eco Premium 6000/12 V
Page 2: ...A AMX0138 B AMX0140 C AMX0142...
Page 112: ...112 RCD 30 mA ICD 0 2 m ein OASE...
Page 113: ...BG 113 A AMX0139...
Page 115: ...BG 115 2 m B IN OUT...
Page 116: ...116 C 10 cm Environmental Function Control EFC 20 40 Environmental Function Control EFC 60 120...
Page 118: ...118 RCD 30 ICD 0 2 OASE...
Page 119: ...UK 119 EMC AMX0139...
Page 121: ...UK 121 2 B IN OUT...
Page 122: ...122 C 10 Environmental Function Control EFC 20 40 Environmental Function Control EFC 60 120...
Page 124: ...124 30 ICD 0 2 OASE...
Page 125: ...RU 125 EMV A AMX0139...
Page 127: ...RU 127 2 B IN OUT...
Page 128: ...128 C 10 Environmental Function Control EFC 20 40 Environmental Function Control EFC 60 120...
Page 130: ...130 RCD 30 mA ICD 0 2 m OASE EMC A...
Page 131: ...ZH 131 AMX0139 1 1 2 2 2 1 2 0 2 1 1 2 3 2 25 50 75 1 2 4 1 2 3 4 5 6 2 7 2 8 9...
Page 132: ...132 A a 1 2 0 2 b 1 2 2 1 2 3 25 50 75 c 2 2 4 d 11 mm...
Page 133: ...ZH 133 2 m B IN OUT C 10...
Page 134: ...134 Environmental Function Control EFC 20 40 EFC 60 120...
Page 135: ...135 XX...