Technical data 

Switching power pack

 

 

100 VA / 12 V DC

 

Primary 

Mains voltage 

V AC 

220 … 240 

Power frequency 

Hz 

50/60 

Max. power consumption 

110 

Cable length 

2.0 

Secondary 

Output voltage 

V DC 

12 

Max. output current 

8.5 

Cable length 

0.5 

Protection type 

 

IP44 

Protection class 

 

II 

Ambient temperature 

°C 

-10 ... +35 

Dimensions (L × W × H) 

mm 

231 × 148 × 68 

Weight 

 

kg 

2.3 

 
 

AquaMax Eco Premium 

 

6000 / 12 V 

12000 / 12 V 

Connection voltage 

V DC 

12 

12 

Max. current consumption 

4.0 

8.5 

Max. power consumption 

45 

95 

Max. delivery rate 

l/h 

6000 

11400 

Max. pumping head 

3.2 

3.2 

Protection type 

Pump 

 

IP68 

IP68 

Connection 

 

IPX4 

IPX4 

Max. immersion depth 

Suction side 

Thread 

 

G2 

G2 

Hose connection 

mm 

25, 32, 38 

25, 32, 38 

Pressure side 

Thread 

 

G2 

G2 

Hose connection 

mm 

25, 32, 38, 50 

25, 32, 38, 50 

Max. grain size of coarse dirt 

mm 

10 

11 

Filter inlet area 

cm

²

 

1000 

1000 

Water temperature (sub-
merged installation) 

During operation 

°C 

(

Permissible water values) 

Outside of operation 

°C 

-20 ... +35 

-20 ... +35 

Ambient temperature 
(dry installation) 

During operation and 
natural convection 

°C 

+4 ... +30 

+4 ... +30 

During operation and 
forced cooling 

°C 

+4 ... +40 

+4 ... +40 

Dimensions 

Length 

mm 

340 

340 

Width 

mm 

280 

280 

Height 

mm 

165 

165 

Length of connection cable 

Weight 

kg 

8.7 

10.5 

 
 

Downloaded from www.watergardeningdirect.com

Summary of Contents for 50382

Page 1: ...AquaMax Eco Premium 6000 12 V 12000 12 V Operating Instructions Downloaded from www watergardeningdirect com...

Page 2: ...ed by children aged 8 and above and by persons with reduced physical sensory or mental capabilities or lack of expe rience and knowledge if they are supervised or have been instructed on how to use th...

Page 3: ...ction device Extension cables and power distributors e g outlet strips must be suitable for outdoor use splash proof Protect open plugs and sockets from moisture Safe operation Do not use the unit if...

Page 4: ...ssible water quality values Permissible water values The following restrictions apply to the unit Never use the unit with fluids other than water Never run the unit without water Do not use in conjunc...

Page 5: ...n 1 2 3 Inlet 2 is opened by approx 25 50 75 this means intake via inlet 1 and 2 based on the set intake ratio Position 4 Inlet 1 is closed intake only via inlet 2 3 Outlet pressure side Connection of...

Page 6: ...56 ft 4 m Possible hazard for persons wearing pace makers Only operate the unit with a safety transformer Protect the unit from direct sunlight Never dispose of the unit with normal household waste Re...

Page 7: ...drawn in via the filter casing inlet 1 Inlet 2 draws in water via a satellite filter or skimmer Set inlet 2 to position 1 2 oder 3 depending on the desired flow rate 25 50 75 Variant c Filtration onl...

Page 8: ...onnections can lead to injuries Please note in particular If a unit has stopped due to overload it can start up unexpectedly Do not reach into the opening of the inlet connection or outlet connection...

Page 9: ...let yet Installation AMX0142 Position the pump horizontally on a firm mud free surface Ensure that the pump is securely positioned Only operate the pump when it is fully submerged A pull rope allows y...

Page 10: ...EN 27 Dry installation of the unit For dry installation install the pump without a filter casing Conversion AMX0144 Downloaded from www watergardeningdirect com...

Page 11: ...141 Do not plug the power plug into the outlet yet Installation AMX0143 Position the pump horizontally on a firm mud free surface Ensure that the pump is securely positioned Downloaded from www waterg...

Page 12: ...Switching on Plug the power plug into the outlet The unit switches on immediately Switching off Pull the power plug from the outlet Environmental Function Control EFC When started up the pump automat...

Page 13: ...harm animals plants and the environment Clean the unit with clean water and a soft brush or sponge wherever possible Remove stub born dirt with the aid of the recommended cleaning agents Cleaning the...

Page 14: ...the figure AMX0145 Reassemble the unit in reverse order During assembly check that the clamp fastening the pump in the holder has securely engaged the connection cable is guided out through the groove...

Page 15: ...ntle the pump as shown in the figure Clean the components with a brush under clear water Check all components for damage Replace damaged or worn components Reassemble the pump in reverse order AMX0147...

Page 16: ...e block check impeller unit for ease of movement Pump does not transport liquid Insufficient conveyed volume Filter casing clogged Clean filter pans Excessive loss in the supply lines Reduce hose leng...

Page 17: ...pumping head m 3 2 3 2 Protection type Pump IP68 IP68 Connection IPX4 IPX4 Max immersion depth m 4 4 Suction side Thread G2 G2 Hose connection mm 25 32 38 25 32 38 Pressure side Thread G2 G2 Hose con...

Page 18: ...g l 50 50 50 Temperature F 39 2 95 39 2 86 39 2 82 4 Wear parts Impeller unit Disposal NOTE Do not dispose of this unit with domestic waste Dispose of the unit by using the return system provided for...

Page 19: ...377 AMX0113 Downloaded from www watergardeningdirect com...

Page 20: ...378 Downloaded from www watergardeningdirect com...

Page 21: ...379 AMX0114 Downloaded from www watergardeningdirect com...

Page 22: ...OASE GmbH Tecklenburger Stra e 161 48477 H rstel Germany 49 0 5454 80 0 49 0 5454 80 9353 info oase com 17704 01 22 Downloaded from www watergardeningdirect com...

Reviews: