background image

1.  Fill the unit with water at the desired temperature approximately 2” above the jet cover.
2.  You can fill your sink with: 

 

a. The optional plumbed faucet (if supplied). 

 

b. The supplied fill hose with connector - to attach to typical sink spout.

3.  To activate or deactivate this appliance, turn the ON/OFF switch to “ON”.
4.  Bath additives (including oil based products) can be used in this foot bath, since their residue can be easily 

cleaned. CAUTION: Use only low foaming additives.

5.  You should always be in a seated position when putting your feet in or removing them from the foot bath.

11

DIRECTIONS FOR USE

FOOT BATH USE

Risk of accidental injury. Exercise care when entering or exiting of the foot bath. Invalid or 

disabled persons should not use the hydro foot bath without trained supervision. Risk of 

scalding: Water temperatures in excess of 104

º

 F (38

º

 C) may be injurious to your health. Check and adjust water 

temperature before use. Should you experience any pain or discomfort while using the foot bath, discontinue use 

immediately and consult your physician. NEVER STAND IN THE FOOT BATH.

CAUTION

Supplied fill hose

FILLING THE FOOT BATH:

DRAINING THE FOOT BATH:

1.  Turn off the foot bath by turning the ON/OFF button to “OFF”.
2.  If your pedicure sink is equipped with the optional drain assembly, gently pull up and slightly twist the drain cover 

to open. To close the drain, twist the drain cover again and let it drop down and seat itself against the strainer 

body.

3.  If your pedicure sink does not have a drain, place the discharge pump on the flat round surface in the bottom of 

the foot bath.

4.  Extend the hose connected to the discharge pump to the area where the water is to be drained (sink). Use the 

suction cup provided to secure the hose to the side of the sink and turn on the discharge pump by plugging the 

pump’s power cord into a GFCI wall outlet. NOTE: This pump must be connected to a GFCI wall outlet for your 

protection from electrical shock. 

5.  When the foot bath appears to be empty, continue running the pump while removing it from the interior of the foot 

bath and place it in the sink or chosen draining area. As soon as the pump and hose are both fully in the sink, 

unplug the power cord to turn off the discharge pump. Fresh water can be used to rinse out the tank during the 

draining procedure. 

NOTE: Do not leave the pump running in the draining area or in a dry foot bath for more than a few seconds because it 

may result in damage to the discharge pump.

Attach this end to 

your sink spout

Place this end in 

foot bath

ON / OFF Switch

water   

discharge   

pump

Summary of Contents for Clodagh Libra

Page 1: ...www oakworks com 717 235 6807 USER MANUAL OAKWORKS Libra...

Page 2: ...within this document is subject to change without notice and should not be construed as a commitment by OAKWORKS Inc OAKWORKS Inc encourages requests for technical specifica tions and the like documen...

Page 3: ...Foot Rest Use 9 Storage Shelf Use 10 Accessory Outlet 10 Hydraulic Daily Cycling 10 Foot Bath Use 11 12 QuickLock Face Rest 13 Manicure Arm Rest Use 13 Adjustable Arm Rest Installation and Adjustment...

Page 4: ...r on product labels indicates a Protective Earth Ground Terminal This symbol when used in this manual or on product labels indicates that the product should be protected from moisture The humidity spe...

Page 5: ...he growth of bacteria 5 DO NOT operate water jets unless completely installed or without water filled to the water level indicator above the jets 6 DO NOT overfill the foot bath 7 DO NOT stand on or i...

Page 6: ...motions Table Weight 342 lbs 155 kg Table Voltage Options 120V 60Hz or 230V 50Hz Wood Stain Natural Maple Finish Storage Shelf 24 x 37 61 x 94 cm usable opening 11 75 x 32 30 x 81 cm OPTIONS ACCESSOR...

Page 7: ...r CUSTOMER SUPPLIED PARTS LIST 1 2 20 long flexible braided water supply lines with 3 8 male end foot bath faucet connection 2 2 Shut off valves for Facility Hot Cold water supply connection 3 2 1 5 P...

Page 8: ...connected to the faucet supply line d The table comes equipped with a 1 5 PVC fitting at the drain location for the installer to connect to e The Flexible 1 5 drain line supplied by customer and inter...

Page 9: ...r connection of the equipment grounding conductor can result in a risk of electric shock Check with a qualified elec trician or service person if you are in doubt as to whether the product is properly...

Page 10: ...functions of the table with the touch of a but ton Follow the directions below to access these functions Do not store or place anything on the cabinet hood or under the backrest This can cause damage...

Page 11: ...fely Do not use the table to transport a client 8 DIRECTIONS FOR USE Grasp at base corner at low height range 9 16 Open end Wrench Leveler Foot 1 Place the table in the location where you plan to use...

Page 12: ...tward until it stops 2 Lower the leg rest until it stops in a vertical position beside the foot bath 3 Repeat for other leg rest CLOSING THE LEG REST 1 With both hands gently lift the leg rest and pus...

Page 13: ...tach to the frame 110V only The total electrical load plugged into this set of outlets is not to exceed 1000 watts ACCESSORY OUTLET HYDRAULIC DAILY CYCLING The Clodagh Libra uses hydraulics and hydrau...

Page 14: ...y turning the ON OFF button to OFF 2 If your pedicure sink is equipped with the optional drain assembly gently pull up and slightly twist the drain cover to open To close the drain twist the drain cov...

Page 15: ...ath and jet cases g Rinse all surfaces with tap water DISINFECTION RE ASSEMBLY a Spray the jet assembly pieces jet cases and foot bath until thoroughly wet with cleaner disinfectant and allow then to...

Page 16: ...dge of Table 3 7 6 cm QuickLock Face Rest Insert dowels into Accessory attachment outlets Loosen Cam Locks adjust face rest into place The Face Rest can be used for either prone or supine positioning...

Page 17: ...d all the way into the hole and drop the arm rest into the horizontal position Pull outward to make sure the arm rest is secure TO LEVEL THE ARM RESTS The Arm Rest height is adjusted at the factory fo...

Page 18: ...head support Note The QuickLock Face Rest is required to use the boiance shelf support system TO INSTALL THE BOIANCE SHELF SUPPORT First install the QuickLock Face Rest at the head end of the table 1...

Page 19: ...rocedure Because of possible chemical incompatibilities between various cleaning products and bleach utmost care must be taken by the user to avoid potential exposure to harmful or toxic by prod ucts...

Page 20: ...ds control and foot control cables and all visible wiring Visually inspect components for obvious damage that could cause problems during operation Check all mechanical functions using the hand contro...

Page 21: ...025 LAPSEB312577ACTTZZPBST Ser LA1565022 Libra 31 x 25 33 x 77 AC TT PB ST TTSKYBLUE 01 04 2013 Order 654321 Notes Sample Product Label Model Numbers and Serial Numbers always start with a letter The...

Page 22: ...Designed for North America Europe Japan Input Service 120 VAC 15 amp 60 Hz 230 VAC 10 amp 50 60 Hz 100 VAC 20 amp 50 Hz Current Draw 3 3 amps 1 8 amps 4 0 amps Power Consumption 400 watts 400 watts 40...

Page 23: ...20 THIS PAGE IS INTENTIONALLY LEFT BLANK...

Page 24: ...on 4 Revision Date 10 15 2020 English Printed in USA CONTACT INFORMATION OAKWORKS Inc 923 East Wellspring Road New Freedom PA 17349 Phone 717 235 6807 FAX 717 235 6798 www oakworks com made in the wit...