CLEANING & DISINFECTION

RECOMMENDED CLEANERS/DISINFECTANTS

To reduce the risk of electric shock:

-  Always unplug this furnishing from the electrical outlet before cleaning.

DANGER

13

Reference the Recommended Cleaners and Disinfectant list (MMINML0008-EN) that came with the 

table. This information can also be found at www.shop.spatable.com under product information.  
All cleaners and disinfectants have the ability to degrade the upholstery to some extent. However, fol-

lowing the recommended cleaner and disinfectant list and cleaning process will provided the best care 

for your table and support a long product life. 
OAKWORKS® recommends a prepackaged wipe for cleaners/disinfectants to ensure best distribution 

of disinfectant for the required kill time, without leaving excess residue and/or overexposing compo-

nents therefore minimizing the potential for damage to materials. Please read and follow disinfectants 

manufacturers’ directions for cleaning and disinfection.
OAKWORKS® does NOT recommend the use of cleaners/disinfectants containing Hydrogen Peroxide, 

Acetic Acid, or Phenolics. These chemicals can cause damage to the appearance and/or material 

integrity of various components. Also, while the recommended cleaners/disinfectants list includes 

products containing Quaternary Ammonium compounds (“quats”), not all products containing quats 

are approved for use. Some contain additional detergents and/or surfactants which can damage some 

materials. 
A note on Bleach: While a 10% sodium hypochlorite (household bleach) solution (EPA No.: 5813-100 

or equivalent) can be an effective disinfectant and is dilute enough to be benign to most materials, it 

alone is not an effective cleaner and a separate product must be used for the initial cleaning steps of 

the procedure. Because of possible chemical incompatibilities between various cleaning products and 

bleach, utmost care must be taken by the user to avoid potential exposure to harmful or toxic by-prod-

ucts of the combination. Also, because bleach leaves a potentially corrosive residue as it evaporates, 

it must be rinsed with clean water after disinfection.

Use of non-approved cleaners or disinfectants may lead to damage to upholstery and other 

materials found on the table and will void the warranty. 

CLEANING PROCESS

Follow the cleaners/disinfectant manufacturers’ directions for use. Please note that cleaning and disin-

fecting an OAKWORKS® table is a two part process. First it must be cleaned of any visible soil, then it 

can be disinfected. OAKWORKS® recommends that the table be positioned in the flat position during 

the cleaning process. Please follow this procedure for best results:

1.  Using an approved cleaner or mild liquid soap and water, clean any visible soil off of the table, 

working from the top to the bottom of the table. It is recommended that the upholstery be 

cleaned at least once a week to prevent disinfectant build up. 

2.  Rinse with clean water and dry with a clean cloth or towel. 
3.  Using an approved disinfectant, thoroughly disinfectant all surfaces of the tabletop and any high-

contact areas such as handles, handsets, etc., making sure they remain wet for the disinfectant 

manufacturer’s recommended contact time. Do not allow disinfectant to pool on the upholstery 

after the recommended contact time. 

4.  Wipe off any excess liquid with a cloth or towel and clean water. 
5.  Dry all surfaces with a clean cloth or towel. 

Avoid using writing instruments or other similar instruments around the upholstery as it can cause per-

manent staining. If this does occur, do not wipe with an alcohol based cleaner. Instead, blot the stain 

with a clean cloth/ paper towel. Use a 10% bleach dilution to remove the stain. Follow this with a rinse 

of clean water. 

Summary of Contents for Clodagh Leo

Page 1: ...www oakworks com 717 235 6807 USER MANUAL OAKWORKS Leo made in the with US imported...

Page 2: ...and should not be construed as a commit ment by Oakworks Inc Oakworks Inc assumes no responsibil ity for any errors that may appear in this document nor does it make expressed or implied warranty of...

Page 3: ...ing the Table 8 Leveling the Table 8 QuickLock Face Rest Accessory Option 9 Adjustable Side Arm Rests Accessory Option 10 Boiance Shelf Support Accessory Option 11 Troubleshooting If the Table Will No...

Page 4: ...es sionals of all specialties On these multifunctional professional tables the practitioner can perform numer ous protocols with ease and comfort The Clodagh Leo is especially effective when professio...

Page 5: ...e table top that can impede motion like stools cabinets accessory parts cleaners etc Use this furnishing only for its intended use as described in these instructions Do not use attachments not recomme...

Page 6: ...SPECIFICATIONS Motion 1 Powered 25 35 64 89 cm Height Range Motion 2 Powered 0 70 Backrest Motion 3 Powered 0 30 Foot Rest Foot Control All powered motions Table Voltage Options 120V 60Hz 230V 50Hz T...

Page 7: ...s equipped with a cord having an equipment grounding conductor and a grounding pin The pin must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all loc...

Page 8: ...table The maximum shelf load weifht is 200 lbs 91 kg The cabinet hood area under the backrest top is not designed for storage or as an area to hold accessories DO NOT use this area for holding anythin...

Page 9: ...to prevent unauthorized use Remove the key when not in use and store out of reach of children HYDRAULIC DAILY CYCLING The Clodagh Leo uses hydraulics and hydraulic fluids to adjust the table height Ma...

Page 10: ...t backrest and footrest positioning with electronic ease Operate the foot control as shown below to raise or lower the height backrest or footrest functions of the table DIRECTIONS FOR USE Back Rest C...

Page 11: ...ur people are required to move the table safely Do not use the table to transport a client DIRECTIONS FOR USE TABLE LEVELING INSTRUCTIONS 1 Place the table in the location where you plan to use it 2 R...

Page 12: ...within 3 of the table to ensure a stable connec tion The recommended length of dowel bracing against the backrest should be at least 2 inches To remove the QuickLock Face Rest just pull the frame fro...

Page 13: ...g the mounting or dismounting of the chair The arm rest is not designed to support the client s weight TO INSTALL THE ARM RESTS The Arm Rests adjust automatically as the back rest moves to remain para...

Page 14: ...head support Note The QuickLock Face Rest is required to use the boiance shelf support system TO INSTALL THE BOIANCE SHELF SUPPORT First install the QuickLock Face Rest at the head end of the table 1...

Page 15: ...e controls again If one or more of the controls still do not work contact Customer Service at 717 235 6807 to arrange replacement IF THE TABLE IS MAKING NOISE DURING HEIGHT ADJUSTMENT CAUTION Disconne...

Page 16: ...rocedure Because of possible chemical incompatibilities between various cleaning products and bleach utmost care must be taken by the user to avoid potential exposure to harmful or toxic by prod ucts...

Page 17: ...control and foot control cables and all visible wiring Visually inspect components for obvious damage that could cause problems during operation Check all mechanical functions using the hand control...

Page 18: ...located on the underside of the foot section of the table top Model and Serial numbers always start with a letter 16796025 CFSA4LF1T410USXXPW Ser CFK123456 06 03 2020 Order 785461 Clinician Electric...

Page 19: ...Amps Electric Shock Protection Class I Equipment Mode of Operation 10 Duty Cycle MAX 2 minutes ON 18 minutes off PERMISSIBLE ENVIRONMENT CONDITIONS Conditions Temperature Humidity Atomic Pressure Nor...

Page 20: ...ks Inc 923 East Wellspring Road New Freedom PA 17349 Phone 717 235 6807 FAX 717 235 6798 www oakworks com Complies with UL 962 CAN CSA C22 2 No 68 09 EN60335 1 EN60335 2 32 European Compliance for CE...