background image

Though the arm rests adjust automatically to remain parallel to the
floor in any position, there will still be times when you will need to
move an arm rest out of the way or remove them altogether. We 
recommend that you raise the arm rest out of the way to allow a client to
get on or off the table. They are designed to be strong and will take a
reasonable amount of weight but they are not designed to be used to
sustain a person’s weight when getting on or off the table. 

To Adjust the Arm Rest:

Before asking a client to mount or dismount from the table we recommend
that you move the arm rest out of the way. The arm rests are easy to move
and manually adjust. First position the tabletop with the backrest in the
upright position and all other section flat. Take hold of the arm rest
firmly and raise the arm rest up and out of the way with a steady swing
until the arm rest is in the highest upright position (see images below).
Hold it in place until your client has mounted (or dismounted)and then
actively move it back into the resting position where it will proceed to
move automatically with the table top.

The arm rest is now set and will adjust automatically as you position the
client for whatever procedure is needed.

There will be times when removal of the arm rests will be needed. This
feature is  helpful when doing massage or helping someone get on or off
the 

C

elesta 

G

emini

. This can be done easily and storage is conveniently

located in the under-table cabinet. They are then right at hand when you
are ready to re-install.

To Remove the Arm Rest:

The arm rest frame has a notched connection to the interior of the the
table top which allows it to move automatically when the table top
changes position. (cont. on next page)

11

DIRECTIONS FOR USE

• Use & Adjustment of the 

C

elesta 

G

emini

Ar m Rests

D

IR

E

C

T

IO

N

S

F

O

R

U

S

E

DIRECTIONS FOR USE

Do not place excess
weight on the Side Arm
Rests. Do not use them in
assisting the client on and
off the 

C

elesta 

G

emini

.

Either Arm Rest can be
repositioned to allow a
client to get on and off
the  

C

elesta 

G

emini

easily.

When making adjustments
the arm rests make certain
that the client’s arms are
away from the working
mechanism.

CAUTION

Do not sit on the Arm Rests.

SIDE ARMRESTS:

Be sure to read all
cautions, warnings 
and instructions given

in the manual to  prevent
injur y to both operator 
and client.

• Side Arm Rests 

Adjusting the Side Arm Rest

IMPORTANT

8

Summary of Contents for Celesta Gemini CLODAGH

Page 1: ...I N S T R U C T I O N M A N U A L OAKWORKS Clodagh Model...

Page 2: ...out notice and should not be construed as a commitment by OAKWORKS Inc OAKWORKS Inc assumes no responsibility for any errors that may appear in this document nor does it make expressed or implied warr...

Page 3: ...Table Cabinet pg 9 Side Arm Rests pg 11 QuickLock Face Rest pg 13 Accessory Option Table Extender pg 15 Moving the Celesta Gemini CLODAGH MODEL pg 15 Section IV Troubleshooting If Table Will Not Chang...

Page 4: ...ii SYMBOL IDENTIFICATION How to Care for Your Upholstery SYMBOL IDENTIFICATION...

Page 5: ...d in documentation on this product indicates that the product should be protected from moisture The humidity specifications for Transport Storage are listed on page 24 This symbol when used in documen...

Page 6: ...wer cords as you put the control box back in the cabinet when troubleshooting to avoid pinching cords between the cabinet base and the control box bracket Before moving the table disconnect the power...

Page 7: ...ht of the base and you could damage the table When operating the Celesta Gemini controls and making any and all adjustments to the table move hands and feet away from the working mechanism of the tabl...

Page 8: ...product is connected to an outlet having the same configuration as the plug No adapter should be used with this product G To remove the accessory from the cabinet Turn the accessory controls to the o...

Page 9: ...an electronically adjustable flextop and a set of 4 pre set automatic positions The variety of height and reclining positions align the Celesta Gemini top so your client s body is at the optimum leve...

Page 10: ...nal hand control allows you to effortlessly change your clients position while they relax on the table Ergonomically designed access top allows the seated practitioner total ergonomic access to the cl...

Page 11: ...ts are determined from floor to top of seat pad using standard padding these measurements can be affected by natural material variations in padding published weight may differ due to options chosen na...

Page 12: ...wrench or an adjustable wrench Adjust each leg individually in turn by adjusting the height of each leveler foot until the unit rests level and steady This adjustment will not effect the function of...

Page 13: ...krest seat and leg rest of the top while the next 2 buttons operate the height of the table The lower 4 buttons activate the pre set positions of the Access Design flex top Follow the directions on th...

Page 14: ...position will move in tandem with the thigh section and maintain the angle of original setting The arm rests will adjust automatically to provide the most in comfort and ergonomics while staying paral...

Page 15: ...3 4 the leg position will move in tandem with the thigh section and maintain the angle of original setting The arm rests will adjust automatically to provide the most in comfort and ergonomics while s...

Page 16: ...automatically to provide the most in comfort and ergonomics while staying parallel to the floor no matter what the position Hand Control CAUTION When operating the Celesta Gemini controls and making...

Page 17: ...hood IMPORTANT 8 IMPORTANT SAFETY NOTE Celesta Gemini UNDER TABLE CABINET Under Table Cabinet To Access the Storage in the Under Table Cabinet The Celesta Gemini has a fully integrated beautiful wood...

Page 18: ...f the way You will find the plug inside the cabinet at the head end of the Celesta Gemini Simply plug the warming cabinet in and move any excess cord inside the wooden cabinet 10 DIRECTIONS FOR USE Ce...

Page 19: ...the table top The arm rest is now set and will adjust automatically as you position the client for whatever procedure is needed There will be times when removal of the arm rests will be needed This fe...

Page 20: ...he notch slip into place Push it in securely and allow the arm rest to rest in the parallel position This resets the arm rest in the proper position for the automatic adjustment feature to be activate...

Page 21: ...frame dowels into the webbing loops being sure to keep the 1st cam lock within 3 of the table to ensure a stable connection The recommended length of dowel bracing against the backrest should be at l...

Page 22: ...ting the height and angle of the face rest gives your clients perfectly comfortable support The face pad is flexible so that you can bring the open ends together or spread them apart to achieve the mo...

Page 23: ...when moving any piece of heavy equipment bend at the knee and lift with your legs beneath you and not with your back Be aware and use proper safe procedures for moving a table of this size to prevent...

Page 24: ...ese steps 1 Obtain the new Hand Control see Parts List pg 27 2 It is recommended that the table be raised to a high height level use foot control if possible as you will need to drop the control box o...

Page 25: ...the mounting plate to face you 5 Follow the coil cord for the hand control back to the place where it connects to the control box Press down on the cord connector tab and unplug the hand control 6 Pul...

Page 26: ...he control box mounting bracket and excess cords back up into the cabinet floor being careful to keep all of the excess cordage out of the way of the control box opening Be sure all cords are away fro...

Page 27: ...knobs are removed rest the control box carefully down on the floor There is plenty of excess cord stored inside the cabinet to allow the control box to sit on the floor 19 TROUBLESHOOTING Foot Control...

Page 28: ...n the bottom plate of the control box bracket and push it into place using slight pressure until the cord restain flange is flush against the control box bracket TROUBLESHOOTING CAUTION Before doing a...

Page 29: ...e all cords are away from the screw area of the knob connections Line up the screw holes hold the control box bracket base plate in position and begin to fasten the knobs onto the 4 screws Hand tighte...

Page 30: ...ing of the fabric Use an anti slip pad to prevent oil from reaching the upholstery and to keep your sheets from slipping Caring for your Celesta Gemini upholstery fabric involves more than just protec...

Page 31: ...791 04 220v 50 Hz Swiss plug Switzerland 7791 02 220v 50 Hz British plug United Kingdom 7791 05 100v 50 60 Hz 3 prong polarized plug Japan Korea 7791 06 220v 50 Hz Australian Plug Australia 23 PRODUCT...

Page 32: ...Cycle 2 min 18 min rest Length Width Height Range Weight Shipping Weight Shipping Crate Dimensions Maximum Working Load Rating Total Outside Dimensions Storage Area 1 Head End Storage Area 2 Foot End...

Page 33: ...r Cord United Kingdom 1 7791 03 Power Cord Europe Italy 1 7791 04 Power Cord Swiss 1 5589 Power Cord Japan 1 7791 06 Power Cord Australia 1 Celesta Gemini LIST OF PARTS MODEL CLODAGH MODEL GMCL 25 LIS...

Page 34: ...S be liable for any special indirect consequential incidental exemplary or punitive damages or costs Use of non approved cleaning solutions voids the guarantee on all fabrics The warranties set forth...

Page 35: ...CONTACT INFORMATION OAKWORKS Inc 923 East Wellspring Road New Freedom PA 17349 Toll Free USA only 800 916 4613 Phone 717 235 6807 Toll Free FAX USA only 877 562 4787 FAX 717 235 6798 www oakworks com...

Page 36: ...INSTRUCTION MANUAL Manual Part MMMLXX0122 CLO Edition 1 English Aug 2007 Printed in U S A MASSAGE TABLES 64CA...