background image

Features

Your thermometer includes:
• Single-point laser sighting (Standard Model)
• Circular laser sighting (Enhanced Model)
• MAX  temperature display
• Backlit graphic display
• Tripod mount
• Durable, ergonomic construction

Options/Accessories

• Nylon Holster
• N.I.S.T./DKD Certification

In the scan mode, the backlit LCD displays
both the current temperature (D) and maximum
temperature (C) in Celsius or Fahrenheit (B).
The unit will hold the last reading for 7 sec-
onds after the trigger is released; the word
HOLD appears (E). The presence of the battery
icon (A) indicates a low battery.

Display

A) Low battery indicator (comes on when 

battery is low)

B) °C/°F symbol 
C) Maximum temperature value (continuously 

updated while the unit is on)

D) Temperature display
E) Scan/Hold indicator

E

A

B

C

D

English

5

Summary of Contents for 35629-00

Page 1: ...Noncontact Thermometer InfraPro 1 Standard Model 35629 00 InfraPro 2 Enhanced Model 35629 10 57511 1 Rev A 4 00...

Page 2: ...F or 0 5 of reading whichever is greater Response time 500 mSec Spectral response 8 14 m Emissivity pre set 0 95 Ambient operating range 0 to 50 C 32 to 120 F Laser Max Laser turns off above 40 C 104...

Page 3: ...Laser Trigger Me taste G chette Gatillo Gatilho Battery Cover Batterieabdeckung Couvercle du lcompartiment pile Tapa de las pilas Tampa da bateria C F Switch C F Schalter Commutateur C F Interruptor...

Page 4: ...d be protected from the following EMF electro magnetic fields from arc welders induction heaters Static electricity Thermal shock caused by large or abrupt ambi ent temperature changes allow 30 minute...

Page 5: ...de the backlit LCD displays both the current temperature D and maximum temperature C in Celsius or Fahrenheit B The unit will hold the last reading for 7 sec onds after the trigger is released the wor...

Page 6: ...face temperatures of hot haz ardous or hard to reach objects without contact How it Works Infrared thermometers measure the surface temperature of an object The unit s optics sense emitted reflected a...

Page 7: ...res To open the unit s handle push the button near the trigger on the underside of the unit and pull the handle down and forward To select C or F slide the top switch A up for Celsius and down for Fah...

Page 8: ...ical make sure the target is at least twice as large as the spot size Yes No Emissivity Emissivity is a term used to describe the energy emitting characteristics of materials Most organic materials an...

Page 9: ...spot shows the center of the measurement area In low light condi tions lighter spots surrounding the laser circle may appear These spots are not used for aiming purposes Use only the laser circle to a...

Page 10: ...bris away with a camel s hair brush Carefully wipe the surface with a moist cotton swab The swab may be moistened with water NOTE DO NOT use solvents to clean the plastic lens Cleaning the housing Use...

Page 11: ...e Uso electromec nico Industrial Manuten o El trica e Industrial Automotive Diesel KFZ Instandesetzung und Wartung Vehicules essence et diesel Automotriz y Diesel Automotive e Diesel Food Safety Leben...

Page 12: ...Oakton Instruments...