O3zone Generator Kit Instructions
8
Programming Procedures
Once the ozone generator has been properly installed, it must be turned on and
programmed in the controller’s settings prior to operation. Settings for ozone generators
takes place in the Service/OEM Filtering level of programming.
To access the Service/OEM Filtering level, the control valve must first be unlocked.
Controllers are factory set in the locked position to avoid any unwanted access to
programming parameters. To unlock the controller, press –, NEXT, +, and CLOCK in order.
The screen will read “UNLOCK” if the sequence is inputted correctly from a general
operating screen. Following the programming procedures below, re-lock the controller by
inputting the same sequence.
Once unlocked, press and hold the NEXT and – buttons simultaneously for three seconds to
access the Service/OEM Filtering screens below. Press NEXT to advance to the “Draw Time”
screen.
ON
OZONE GENERATOR
30:00
MIN
GENERATE OZONE
SET
SET
OFF
GENERATOR ALARM
SET
60:00
MIN
DRAW TIME
SET
On the DRAW TIME screen, press and hold the CLOCK and +
buttons simultaneously for three seconds to access Ozone
Generator Settings
Use the + or – buttons to select ON. This turns the Ozone
Generator on.
This option determines how long the ozone generator will
run for. Default is 30 minutes.
Use the + or – buttons to turn alarm ON or OFF. When ON,
a SERVICE OZONE message will display when failure is
detected.