AX1 LED User Manual
Rev 1.0
7.1
TESTING SYSTEM
Users are advised to test the system frequently. System must be tested at least
once every
three months
. If the system is not functioning accordingly, please contact the nearest dealer
for technical assistance. In order to test , system must be on normal mode. There are
4
types
of tests: walk test, bell test, CMS test and battery test.
7.1.1 LOCAL SYSTEM TEST (WALK TEST)
Command
Information
Initiate
Walk Test
Press
[COM] [1] [1] [#]
Walk test allow on-site testing for each zone of the
system
The keypad will beep twice upon confirmation
The
SERVICE
and
ARMED
light will
FLASH
to
indicate that the system is currently under the
Walk
Test.
Each time zone faulted, corresponding zone light will
fast flash
and keypad will chime until system exit
walk test.
To
exit
, press
any
key.
The keypad will beep twice upon confirmation. Back
to normal mode.
7.1.2 BELL TEST
Command
Information
Test bell
or siren
Press
[COM] [1] [2] [#]
Once command has been acknowledged, the keypad
and bell will sound continuously for 3 seconds.
7.1.3 MANUAL TEST REPORTING FOR CMS
Command
Information
Manual
test
reporting for
CMS
Press
[COM] [1] [3] [#]
The keypad will beep twice upon confirmation. Panel
will generate message to CMS.
7.1.4 BATTERY TEST
Command
Information
Test
back-up
battery
Press
[COM] [1] [4] [#]
Battery test takes few seconds
The keypad will beep twice or reject tone as a result.
The indication of low battery can be seen from View
System Trouble Mode.
32