background image

AX1 LED User Manual 

 

                          Rev 1.0 

 

 

 

2.1

 

HOME AUTOMATION CONTROL

 

USING LED KEYPAD

 

 
 
 

 
 

 

 

 

 
 

 
 

 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 

Press 

 and hold for 2 sec 

Press the relevant module number 
(

to 

8

) to toggle output 

Zone LED will show the current 
output status.  

 

Press [ 

] to 

ON

 all outputs 

Press 

 to return back to 

normal mode. 
   

Zone LED turn 

ON

 to indicate 

outputs are on.

 

14 

Press [ 

] again to 

OFF

 all 

outputs 

Summary of Contents for AX1 LED

Page 1: ...Security Home Automation System AXI LED USER MANUAL REV 1 0 ...

Page 2: ...AX1 LED User Manual Rev 1 0 ...

Page 3: ...DISARMING 1 0 2 1 IN ARMED MODE 1 0 2 2 IN ALARM MODE 1 0 3 ALARM REPORT 1 0 4 CLEAR ALARM MEMORY 1 0 5 BYPASSING ZONE 1 0 5 1 QUICK BYPASSING ZONE 1 1 ARM DISARM USING TELEPHONE 1 1 1 ARM DISARM WITH VOICE ACTIVE 1 1 2 ARM DISARM WITH BEEPER CHAPTER 2 HOME AUTOMATION CONTROL 2 0 INTRODUCTION 2 1 HOME AUTOMATION CONTROL USING LED KEYPAD 1 2 4 6 7 7 7 7 8 8 8 9 9 10 10 11 11 12 13 13 14 ...

Page 4: ...MING 4 0 PIN CODE EDIT 4 0 1 MASTER USER 4 0 2 USER 4 0 3 GUEST 4 0 4 DURESS 4 0 5 TIMER 4 0 5 1 IO ON 4 0 5 2 IO OFF 4 0 5 3 ARM 4 0 5 4 DISARM 4 0 6 CLOCK 4 0 7 INSTALLER ACCESS 4 0 8 FAST KEY ACCESS 4 0 9 PHONE LINE LOSS DETECTION CHAPTER 5 KEYPAD SETTINGS 5 1 DOOR CHIME 5 2 KEYPAD SETTING VIEW 15 15 16 17 18 20 20 20 21 21 22 22 22 23 23 23 24 24 25 26 26 26 ...

Page 5: ...ERT TO USER THROUGH TELEPHONE 6 3 1 WITH VOICE ACTIVE 6 3 2 WITH BEEPER CHAPTER 7 SYSTEM CHECKING 7 0 TROUBLE VIEW 7 0 1 QUICK TROUBLE VIEW 7 1 TESTING SYSTEM 7 1 1 LOCAL SYSTEM TEST WALK TEST 7 1 2 BELL TEST 7 1 3 MANUAL TEST REPORTING FOR CMS 7 1 4 BATTERY TEST GLOSSARY LIMITATIONS SYSTEM INFORMATION QUICK REFERENCE 27 27 27 27 28 29 30 31 31 31 32 32 32 32 32 33 34 35 37 ...

Page 6: ... bypassing When you bypass a zone the zone is temporarily removed from the alarm system But always remember that bypassed zones are not protected How your AX1 alarm and home automation system works When a detection device is triggered the zone indicator will light up If the alarm system is armed the control panel responds by reporting an alarm condition The control of the system can be done either...

Page 7: ...ne EOL Normally Open NO Normally Close NC 14 Adjustable loop response sensitivity 15 Resetable auxiliary power supply upon Alarm Clearing 16 Key Switch function Latch Momentary 17 Dedicated Tamper zone 18 AC power supply monitoring 19 Low battery indication 20 Short circuit indication protection 21 Bell Loss indication 22 Bell Test function 23 Telephone line loss detection 24 Programmable Event Re...

Page 8: ...al Rev 1 0 33 Fast Key on Keypad for Easy menu access 34 Duress code 35 Walk test function 36 Double Call in Feature for Fax Machine telephone line sharing 37 16 Event Trigger Outputs with programmable countdown timer 3 ...

Page 9: ...pad Setting Night Arming View Timer Fire Force Arming Home Automation Clear Alarm Memory Emergency Door Chime on off View Trouble Zone Bypass Mode Panic Cancel Enter Command 4 ZONE STATUS INDICATORS SYSTEM STATUS INDICATORS Power Green Armed Red Service Yellow KEYPAD ACCESS ...

Page 10: ...erior zones are not bypassed When there are zone still open user is at home Night Arming Normal Status The perimeter zone is armed instantly while user stays at home The interior zones are automatically bypassed The delay zones become instant zones When everyone come back to home user want to sleep NOTE Zone refers to the designated areas that are protected by the AX1 system Zone status refers to ...

Page 11: ... KEY FUNCTION COM Key Command Key Enter Key Cancel No Description Power Armed Service Zones 1 Normal Mode OFF Pending 2 Arming ON Pending 3 Home Automation Mode Flash OFF Flash Pending 4 User Programming Mode Flash Flash Flash Pending 5 AC power failure OFF ON Pending 6 Trouble occurs ON Pending 7 View Trouble Mode Flash ON according to the type of trouble 8 Zone Status Triggered Bypassed Alarmed ...

Page 12: ...seconds Auto Home Arming Press and hold the button for 2 seconds Day Arming Press and hold the button for 2 seconds Night Arming Press and hold the button for 2 seconds Force Arming 7 Press User PIN and Exit delay starts to count down with sound Press User PIN and hold for 2 sec Press User PIN and hold for 2 sec Press User PIN and hold for 2 sec System is now armed ...

Page 13: ...mmand Information To disarm the system press User PIN The keypad will beep twice upon confirmation Otherwise the error tone will sound if PIN numbers are entered wrongly The ARMED light will go OFF once the system is disarmed 8 System is now disarmed Press User PIN to disarm ...

Page 14: ...ate of alarm only PIN entry is allowed In other words only DISARM is allowed 1 0 4 CLEAR ALARM MEMORY When alarm occurs the strobe lights and the bells will be turned on If the system is disarmed it could only turn off the bell but not the strobe light Thus the user needs to clear the alarm memory to turn OFF the strobe light Besides that once the alarm memory is cleared the auxiliary power supply...

Page 15: ... normal mode Once the system is disarmed the entire zone will be unbypassed 1 0 5 1 QUICK BYPASSING ZONE Command Information Press and hold for 2 seconds Bypassing zone 10 Press and Hold for 2 sec Screen will show the current bypassed zone status Zone LED turn ON to indicate zones are bypassed To toggle ON OFF press relevant zone number 1 to 8 Press to return back to normal mode ...

Page 16: ...y 3 attempts allowed System hangs up Press Press 0 Incorrect code Please enter your code Main Menu Press 1 for Security Menu 2 for Automation Menu 0 to Exit Security Menu Press 1 to ARM 2 to DISARM for Main Menu 0 to Exit Arming Menu Press 1 to arm Partition 1 for Main Menu 0 to Exit AX1 LED only support partition 1 Press 1 Arming accepted Press for Main Menu 0 to Exit Thank you Welcome Please ent...

Page 17: ... Auto Home Arming Press 1 0 1 To arm the system with Away Arming Press 1 1 1 To arm the system with Day Arming Press 1 2 1 To arm the system with Night Arming Press 1 3 1 To arm the system with Force Arming Press 1 4 1 To DISARM Press 2 1 Press 0 System Hangs up Acknowledgement Tone Beep Twice Error Tone Long Beep Invalid Code Correct Code 5 Slow Tones Only 3 attempts allowed If arming accepted ke...

Page 18: ...outputs or normal outputs which are controlled either by LED keypad real time clock timer or telephone remote control Recommended air conditioner with memory backup or last state memory in Malaysia is as below Wall Mounted Split Air Conditioner Brand Acson Model AWM101 1 0 HP AWM151 1 5 HP AWM201 2 0 HP AWM251 2 5 HP AWM301 3 0 HP Ceiling Cassette Split Air Conditioner Brand Acson Model ACK15B 1 5...

Page 19: ...AD Press and hold for 2 sec Press the relevant module number 1 to 8 to toggle output Zone LED will show the current output status Press 0 to ON all outputs Press to return back to normal mode Zone LED turn ON to indicate outputs are on 14 Press 0 again to OFF all outputs ...

Page 20: ...nter your code Main Menu Press 1 for Security Menu 2 for Automation Menu 0 to Exit Press Master PIN within 1 minute Correct Code Invalid Code Press 2 Automation Menu Press 1 to ON Output 2 to OFF Output 3 to ON ALL Output 4 to OFF ALL Output for Main Menu 0 to Exit Press 01 for Output 1 02 for Output 2 03 for Output 3 04 for Output 4 08 for Output 8 for Main Menu 0 to Exit Press 1 to 4 All Output ...

Page 21: ...orrect Code Incorrect Code Acknowledgement Tone Beep Twice Error Tone Long Beep To turn ON the output Press 4 Output Number To turn OFF the output Press 5 Output Number Output Number 01 to 08 00 for all outputs Press 0 System Hangs up Acknowledgement Tone Beep Twice Error Tone Long Beep Invalid Code Correct Code 16 ...

Page 22: ...er Press COM 3 2 1 4 Home automation OFF timer Press COM 3 3 Auto ARM timer Press COM 3 4 Auto DISARM timer CHAPTER 3 VIEW TIMER MODE Press COM 3 1 1 4 or COM 3 2 1 4 or COM 3 3 or COM 3 4 If timer was not set all zone LEDs 1 9 will on 4 times If timer was set 4 digit timer will display one by one base on 24 hour format Keypad will back to normal mode after show 4 digit timer Example Timer ON 3 00...

Page 23: ... PINs can be set to 4 to 6 digits Edit Duress Code User can edit or delete their existing duress code from this menu CODE must be set in 4 digit else error tone sound Edit IO Module ON Timer This feature is to set the timer to turn ON the outputs automatically Timer set must be in a 24 hour format The system support 4 IO timers so user can set 4 different time to turn ON the outputs Keypad will ar...

Page 24: ...matically every 3 hours Fast Key Access Enabling or disabling the fast key access Phone line loss detection Enabling or disabling the phone line loss detection When in normal mode press Master PIN COM to enter user programming mode To return to normal mode press COM 19 ...

Page 25: ...re in Edit User s PIN option Step 2 Enter the user number 2 7 User 2 7 Normal user Step 3 Press the new PIN 4 6 digits PIN Zone light will be ON one by one to indicate that the PIN has been entered Step 4 Repeat the new PIN 4 6 digits PIN Zone light will be ON one by one to indicate that the PIN has been entered The keypad will beep twice for valid entry Step 5 Enter access level Toggle key 1 4 Pr...

Page 26: ...ey 1 Arm and Disarm On 1 Off 0 Key 2 Arm 1 Disarm 0 Key 3 Bypass Enable 1 Disable 0 Key 4 Open Close Report 1 Disable 0 By pressing Key 1 4 will toggle its status to ON OFF The keypad will beep twice for valid entry Step 6 Enter Guest Time 0 15 Valid entry is 0 15 for number of days The keypad will beep twice for valid entry Note Pin 000000 is not allowed to be used as password After enter the use...

Page 27: ...that the time has been entered Enter 0 will delete the I O Module ON Timer The keypad will beep twice for valid entry 4 0 5 2 IO OFF Command Information Step 1 Press 4 Zone 1 light will be ON to indicate that the command has been accepted and the users are in Edit IO OFF Timer option Step 2 Enter the Timer Number Timer number Timer 1 to Timer 4 Step 3 Enter the IO ON Time _ _ _ _ Please enter inte...

Page 28: ...and has been accepted and the users are in Edit Auto Disarm Timer option Step 2 Enter the Auto DisarmTime _ _ _ _ Please enter international time according to the 24 hour format E g 1400 for 2pm Zone light will be ON one by one to indicate that the time has been entered Enter 0 will delete the Auto Disarm Timer The keypad will beep twice for valid entry 4 0 6 CLOCK Command Information Step 1 Press...

Page 29: ... is advised to disable installer access once the system is hand over User should keep installer accessibility barred all the time unless requested by installer during commissioning or servicing 4 0 8 FAST KEY ACCESS Command Information Step 1 Press 9 Zone 1 light will be ON to indicate that the command has been accepted and the users are in Fat Key Access option Step 2 Press key 1 to toggle the ON...

Page 30: ... Enable disable of Phone Line Loss Detection Zone light 1 will toggle ON OFF according to Phone Line Loss Detection setting status Step 3 Press Keypad will beep twice for valid entry Note Initially phone line loss detection will be toggling OFF Disable When phone line loss detection enable and phone communication option enable in installer programming alarm will be trigger if phone line cut off In...

Page 31: ...options will toggle the arm tone to ON OFF Pre warn Tone Press COM 2 3 This options will toggle the pre warn tone to ON OFF Key press Tone Press COM 2 4 This options will toggle the key press tone to ON OFF Toggle ON OFF for all keypads setting Press COM 2 5 This option will toggle all keypad settings all at one time Under this command all keypad settings Door Chime Back light Arm Tone Pre warn To...

Page 32: ...n the event where the user is forced by an intruder or robber to disarm the alarm system user can disarm the alarm system by using Duress Code By pressing Duress Code user can access the menu to disarm the system At the same time a silent signal will be sent to any designated telephone number or central monitoring station CMS to call for help Provided the system is connected to CMS The siren and s...

Page 33: ...g comes in two reporting method no voice or beeper reporting and voice reporting if voice module is installed System will report the status of the system to user when an event happened accordingly to the list below Reporting Zone indication Description Zone xx Violated Zone has been violated Zone xx Restored Alarm in zone xx has been restored Emergency Emergency occurring Fire Fire occurring Panic...

Page 34: ...olated Zone 7 Violated Emergency for Main Menu 0 to Exit Security Menu 1 to ARM for Main Menu 0 to Exit Automation Menu Press 1 to ON Output 2 to OFF Output 3 to ON ALL Output 4 to OFF ALL Output for Main Menu 0 to Exit Refer 1 1 1 page 11 Refer 2 2 1 page 14 Thank you Press 0 System hangs up 29 Answer Call Slow Beeps Press any key to acknowledge system Zone Indication Reporting ...

Page 35: ... 1 To arm the system with Night Arming Press 1 3 1 To arm the system with Force Arming Press 1 4 1 To DISARM Press 2 1 To turn ON the output Press 4 Output Number To turn OFF the output Press 5 Output Number Output Number 01 to 08 for output 1 to 8 00 for all outputs Press 0 System Hangs up Acknowledgement Tone Beep Twice Error Tone Long Beep Invalid Code Correct Code Continuous tone with differen...

Page 36: ...w Trouble mode Press The service light will be ON if the trouble conditions still remain The designated zone light will be restored back to the actual zone s status Trouble Display Causes DC Loss Low Battery Zone 1 LED turn on Backup battery in weak or backup battery is not available Bell Strobe Siren Loss Zone 2 LED turn on Either bell strobe or siren is loss External Communication Error Zone 3 L...

Page 37: ...t the system is currently under the Walk Test Each time zone faulted corresponding zone light will fast flash and keypad will chime until system exit walk test To exit press any key The keypad will beep twice upon confirmation Back to normal mode 7 1 2 BELL TEST Command Information Test bell or siren Press COM 1 2 Once command has been acknowledged the keypad and bell will sound continuously for 3...

Page 38: ...22 Entry Delay The amount of time that you are allowed to enter the premises when the system is armed Exit Delay The amount of time that you are allowed to leave the premises when the system is arming Guest PIN A temporary four to six digit code which is used to arm and disarm the system from the keypad User PIN A four to six digit code which is used to arm and disarm the system from the keypad Ma...

Page 39: ... premise to a central monitoring station may be out or temporarily out of service Telephone station lines are subjected to compromise by sophisticated method of attack Smoke detector used in conjunction with the alarm system may not sense fires that start where smoke cannot reach the detector such as wall roof or the other side of the door Smoke detector also may not sense a fire on another level ...

Page 40: ...er 2 Receiver Number 2 Receiver Type User CMS Receiver Pattern Permanent Backup CMS Account Number 2 Telephone Number 3 Receiver Number 3 Receiver Type User CMS Receiver Pattern Permanent Backup CMS Account Number 3 Telephone Number 4 Receiver Number 4 Receiver Type User CMS Receiver Pattern Permanent Backup CMS Account Number 4 Telephony Settings Dial Attempt times Redial Attempt times Number of ...

Page 41: ...6 Light Interior Instant Delay 24 Hours Yes No 7 Light Interior Instant Delay 24 Hours Yes No 8 Light Interior Instant Delay 24 Hours Yes No Output Settings Output Output Description 1 2 3 4 5 6 7 8 Output Timers Timer Timer ON Timer OFF Output No Timer 1 Date Time Date Time Timer 2 Date Time Date Time Timer 3 Date Time Date Time Timer 4 Date Time Date Time Arm Disarm Timers Timer Timer ARM Timer ...

Page 42: ...ity and hold 2s Emergency Alarm To trigger Emergency alarm and hold 2s Fire Alarm To trigger Fire alarm and hold 2s Panic Alarm To trigger Panic alarm 2 To Disarm the house 1 PIN CODE 3 To stop the bell siren and strobe light when alarm trigger 1 PIN CODE 2 Check the alarm report for violated zone 3 Clear alarm by pressing 6 and hold for 2 second to resume to normal status Strobe light will turn o...

Reviews: