background image

Mineral Mizer Owner’s Manual (rev. 7) 

DWS-SADI  

 

Question or comments? Contact O-SO Pure at (800) OSO-PURE or 

[email protected]

Copyright

©

 2016 O-SO Pure. All rights reserved. 

Page 7 of 16 

7. 

Drain Saddle

 – The Drain Saddle installs on a standard 1½” O.D. vertical section of drain pipe. 

Install it above the trap and away from the garbage disposal outlet, if any. Position it to allow 
adequate space for drilling through the pipe, angling the fitting in the direction of the Mineral 
Mizer installation. Tighten the Drain Saddle evenly and firmly so a good seal is made. Avoid over 
tightening. Drill a 5/16” hole in the drain pipe through the drain fitting opening while supporting 
the drain against drilling pressure.

 

Connect the Mineral Mizer to plumbing 

8.

 

Filter Sumps

 - Remove the plastic shrink wrap from all filters. Place the filter with the yellow dot 

in the left Filter Sump and install it on the filter cap marked with a yellow dot on the bracket. 
Place the filters with the red dots in the center and right Filter Sumps, again marked by 
corresponding dots on the bracket. Hand-tighten all the Filter Sumps so they are snug. Do not use 
the provided filter wrench to tighten the filter Sumps unless absolutely necessary. Place the 
Mineral Mizer in its service location. 

 

9.

 

Drain Tube (black)

 - After cutting to the appropriate length, 

connect the Drain Tube between the Mineral Mizer’s check 
valve marked 

To Drain

 and the Drain Saddle fitting. 

 

10.

 

Feed Water Tube (red)

 – 

After cutting to the 
appropriate length, insert the 
elbow end of the Feed Water 
Tube into the fitting marked 

To Feed Water

 and the other 

end into the Angle Stop Valve 
fitting previously installed on 
the sink plumbing. 

 

11.

 

Tank Tube (blue)

 – Connect the Tank Tube to the 3/8” elbow on 

the Storage Tank Connector at back left, while the other end 
hooks up to the elbow ball valve on the storage tank. Keep tank 
valve 

CLOSED 

for the moment.

 

 

12.

 

D.I. Dispensing Connector (blue)

 

 

*

FOR DWS-SADI 

(DISPENSING CONNECTOR TO RED FAUCET):

 

Insert one end 

of 3/8” BLUE Tube length into D.I. Dispensing Connector and the other 
end into the bottom of the Red Faucet. Install the Red Faucet per its 
included instructions. Location options include the sink pop-out or 
through the countertop overhanging the sink. 
 
 

 

Tank Tube 

 

Drain Tube 

 

Feed Water Tube 

Summary of Contents for DWS-SADI

Page 1: ...al rev 7 DWS SADI Question or comments Contact O SO Pure at 800 OSO PURE or support osopure com Copyright 2016 O SO Pure All rights reserved Page 1 of 16 MINERAL MIZER DEIONIZED WATER SYSTEM INSTALLATION OPERATION SERVICE MANUAL ...

Page 2: ...e Inspection 5 Pay Attention to All Warnings 5 INSTALLATION GUIDE 6 Locate the Mineral Mizer 6 Connect the Mineral Mizer to plumbing 7 OPERATING THEORY 10 SERVICING YOUR MINERAL MIZER 10 Schedule 10 Filter Stocking Strategies 11 Changing Filters 11 Sanitizing the Mineral Mizer 12 Materials required 12 Other requirements 12 Sanitization Procedure 12 TROUBLE SHOOTING GUIDE 13 WARRANTY 14 THIS PAGE I...

Page 3: ...nded Introduction Congratulations on your purchase of the Mineral Mizer autoclave water system The Mineral Mizer produces deionized DI water from tap water allowing you to exit the boiled bottled distilled water hamster wheel When routinely serviced your Mineral Mizer will economically reliably deliver all of your DI water needs for years to come The DI water produced by the Mineral Mizer normally...

Page 4: ... Take inventory of all items supplied to ensure none are missing The box should contain the following Mineral Mizer Head Filters Spanner Wrench Filter Housings Blue 3 8 Tube Feed Water Tube w Press Reg red drain tubing blsck tank Drain Saddle Angle Stop Valve chrome faucet MODEL DESCRIPTION INSTALL IN TANK S DI WATER DISPENSE RO WATER DISPENSE DWS SADI Mineral Mizer SC or MR steel 6 gallon red fau...

Page 5: ...the Tank is usually placed at the back and the Mineral Mizer is positioned on the right side of the cabinet providing maximum viewing exposure to the right center clear filter sumps If this is a Mineral Mizer II make sure that it is placed within the 15 foot range of the dispensing gun assembly Hand tighten the filter sumps onto the Mineral Mizer head before placing it into the cabinet for spatial...

Page 6: ...Valve on the cold water stub plumbing Reconnect the faucet s cold water tube to the top of the Angle Stop Valve Close the Angle Stop Valve and turn on the cold water supply checking for leaks 6 Install the chrome and red faucets Install the chrome red faucets per its included instructions Location options include the sink pop out or through the countertop overhanging the sink IMPORTANT WARNING PLE...

Page 7: ...rresponding dots on the bracket Hand tighten all the Filter Sumps so they are snug Do not use the provided filter wrench to tighten the filter Sumps unless absolutely necessary Place the Mineral Mizer in its service location 9 Drain Tube black After cutting to the appropriate length connect the Drain Tube between the Mineral Mizer s check valve marked To Drain and the Drain Saddle fitting 10 Feed ...

Page 8: ...oth faucets are all CLOSED This will create enough water pressure in the system to see if there are any possible leaks coming from system Tighten the Filter Sumps with the Sump Wrench if necessary Check the tank for leaks at valve as well Production Startup 15 Open the RO Tank valve 16 Turn ON the water supply by opening the Inline Valve on the Feed Water Tube 17 Open Chrome Faucet 18 Allow the Mi...

Page 9: ...f DI filters 21 The Mineral Mizer is now ready for use To check the mineral content slide the Water Quality Monitor s switch to the FEED position Turn the monitor on by pressing its ON OFF switch The display shows the water s mineral content expressed in ppm TDS This number will normally be in the 000 002 range If the number is higher than 004 allow the tank to fill until the display is consistent...

Page 10: ...es are directly affected by the RO feed water pressure and temperature The life of the membrane is determined by measuring the decline in the membrane s rejection rate over time Sans this level of measurement the membrane should be replaced every 24 to 36 months This could be earlier depending upon quality of feed water DI Filters The red dot DI filters contain two types of beads coated with ion e...

Page 11: ...ilters Some possibilities include consumption by staff taking water for home use or new boiled water applications Changing Filters 1 Turn off the water supply by closing the Inline Valve on the Feed Water Tube 2 If this filter change is the result of a high TDS water reading TDS ppm 5 discard the Tank water by opening the Chrome Faucet over the sink until water flow stops Release the valve 3 Close...

Page 12: ...ed Thoroughly wash hands with soap before beginning installation and or sanitization procedure If your hands come into contact with any unsanitary surface while performing this procedure or the installation hands should be rewashed with soap Any surfaces used to work with to set various components on to dry should be cleaned and disinfected Replacement filters membranes and cleaned components shou...

Page 13: ... NO WATER OR NOT ENOUGH WATER Feed water shut off Turn on feed water Storage tank valve shut off Open tank valve Plugged or crimped lines Remove blockage or crimp in lines Pre filter cartridge clogged Replace pre filter cartridge Low feed water pressure Feed water pressure at membrane must be 40 psi LOW FLOW RATE FROM FAUCET DISPENSER Storage tank valve partially closed Open tank valve completely ...

Page 14: ... 800 OSO PURE to arrange shipment IMPORTANT To ensure proper treatment of source water purchaser must replace all filters and the UV lamp if applicable as directed in this manual Failure to service this product as directed voids this Warranty Filters and UV lamps if applicable must be purchased from O SO PURE for ANY and ALL CLAIMS TO BE BACKED BY O SO PURE DATE OF PURCHASE _______________________...

Page 15: ... Mizer Owner s Manual rev 7 DWS SADI Question or comments Contact O SO Pure at 800 OSO PURE or support osopure com Copyright 2016 O SO Pure All rights reserved Page 15 of 16 this page intentionally left blank ...

Page 16: ...rder Rebate will not be applied retroactively o Only one 1 certificate may be redeemed per eligible O So Pure water system Dealer o Dealer and dealer employees are not eligible for referral fee o When submitting your purchase order to O SO Pure include an image of this certificate clearly showing the purchaser information rebate will be sent by O So Pure directly to the purchaser identified above ...