Mineral Mizer Owner’s Manual (rev. 7)
DWS-SADI
Question or comments? Contact O-SO Pure at (800) OSO-PURE or
.
Copyright
©
2016 O-SO Pure. All rights reserved.
Page 12 of 16
8.
It will take about 3 hours to fill the Tank, depending on local water pressure and temperature. You will
see black carbon fines for awhile during the initial flushing of the final filter after a filter change. This is
normal.
Sanitizing the Mineral Mizer
Because the DI water produced by the Mineral Mizer is intended to be boiled, the bacterial content of this
water isn’t normally a concern. If, however, there is evidence that bacterial contamination is becoming a
problem with your Mineral Mizer, following this procedure to perform a complete sanitization cycle.
Materials required
•
Mild soap solution - Soap used should be as basic as possible and not contain any fragrances or additives.
•
Soft brush - Don’t use scouring pads or instruments that can scratch surfaces.
•
Measuring spoon or device.
•
Household bleach – unscented, typically containing 5.25% sodium hyperchlorate.
•
One (1) Gallon of potable water - to mix up a disinfectant solution.
•
Drip pan or catch basin - to collect any solution or water spilled.
•
Paper towels - to cleanup any spills.
•
Silicone Based Lubricant or KY Jelly- to apply to O-Rings. Don’t use petroleum-based lubricants.
Other requirements
•
Before beginning installation and/or sanitization procedure, make sure that all tools used are disinfected.
•
Thoroughly wash hands with soap before beginning installation and/or sanitization procedure. If your
hands come into contact with any unsanitary surface while performing this procedure or the installation,
hands should be rewashed with soap.
•
Any surfaces used to work with to set various components on to dry, should be cleaned and disinfected.
•
Replacement filters, membranes and cleaned components should be handled as little as possible.
•
A new pair of latex or surgical type gloves may be used to perform any sanitization procedure. If the gloves
come into contact with any unsanitary surface while performing this procedure, the gloves should be
disinfected or replaced.
Sanitization Procedure
1.
Turn off the Inline Valve on the Feed Water Tube.
2.
Discard the Tank water by opening the valve of the Chrome Faucet over the sink until water flow stops.
Release the valve.
3.
Place the Mineral Mizer into the drip pan or basin to catch water remaining in the housings as you remove
the Filters and RO membrane.
4.
Disconnect the feed tube from the RO membrane module. Unscrew the end cap and remove the
membrane. Discard the RO membrane if replacing or place it on a disinfected surface.
5.
Remove the Filter Sumps with the Sump Wrench and remove the Filters.
6.
Using a cloth or soft brush, clean the Filter Sumps and RO membrane housing with soap and clean water.
7.
Lubricate the Filter Sump and RO membrane cap O-rings with silicone lubricant.
8.
Reinstall the red dot Filter Sumps (no filters).
9.
Reinstall the RO membrane cap and reconnect its feed water tubing.
10.
Mix a disinfectant solution of 1 teaspoon of 5.25% bleach in 1 gallon of water.