Continuation of test mode
Activation of the
address menu
to next menu item
enter address menu
(see Chapter
7.1.3 Address menu)
26
S
L
Activation of
edit mode
to standard display
enter edit mode
(see Chapter
7.1.4 Edit mode)
S
L
Table 10: Test mode
7.1.3 Address menu
The address menu is available only if the meter is equipped with an M-Bus or RS485
interface.
The primary address, the secondary address and the baud rate can be changed in the
address menu.
The meter is set at the factory to the following settings:
Primary address: 001
Secondary address: 8-digit with leading zeros, e.g. 00390747 (serial number)
Baud rate: 2400 Baud
Pressing the button briefly switches to the next menu item. When the button is held down
longer (> 5 s) the display jumps from any position of the standard menu back to the
standard display. This happens whenever the button is not pressed during a period
longer than 5 minutes.
At the end of the address menu it is possible to exit the address menu by holding down
the button (Display "Escape") or to switch to the start of the address menu by pressing
the button briefly.
= short actuation (t
actuation
< 2 s)
= long actuation (2 s
≤
t
actuation
< 5 s)
L
S