background image

Number

TORQ

® 

G2 Body 0.75

TORQ

® 

G2 Body 1.0 

TORQ

® 

G2 Body 2.0

1

Lid 70

Art.: T-BSP_4331

Lid 70

Art.: T-BSP_4331

Lid 100

Art.: T-BSP_4348

2

Filter sponge for 

lid 70

Art.: T-BSP_2535

Filter sponge for 

lid 70

Art.: T-BSP_2535

Filter sponge for 

lid 100

Art.: T-BSP_2542

3

O-Ring  

for lid 70

Art.: T-BSP_2559

O-Ring  

for lid 70

Art.: T-BSP_2559

O-Ring  

for lid 100

Art.: T-BSP_2566

4

Tube 750 ml

Art.: T-BSP_4355

Tube 1.000 ml

Art.: T-BSP_4362

Tube 2.000 ml

Art.: T-BSP_4379

5

Separating grid with 

acrylic stick 70  

(0.8 mm)

Art.: T-BSP_4386

Separating grid with 

acrylic stick 100  

(0.8 mm)

Art.: T-BSP_4393

6

Grid 70 (0.8 mm)

Art.: T-BSP_4409

Grid 70 (0.8 mm)

Art.: T-BSP_4409

Grid 100 (0.8 mm)

Art.: T-BSP_4416

7

Grid 70 (1.5 mm) 

Art.: T-BSP_ 4454

Grid 70 (1.5 mm) 

Art.: T-BSP_ 4454

Grid 100 (1.5 mm) 

Art.: T-BSP_ 4461

8

Insert 70

Art.: T-BSP_ 4423

Insert 70

Art.: T-BSP_4423

Insert 100

Art.: T-BSP_4430

PARTS LIST TORQ

® 

G2 BODIES

16

Summary of Contents for TORQ G2 Body 0.75

Page 1: ...TORQ G2 Dock TORQ G2 Body 0 75 1 0 2 0 TORQ G2 system reactor for filter media INSTRUCTIONS EN...

Page 2: ...ions and safety information carefully before you use the device CONTENTS SAFETY INFORMATION 3 WARRANTY 4 INSTALLATION AND OPERATION 6 RECOMMENDED MEDIA CAPACITIES AND TANK SIZES 12 FAQ AND TROUBLE SHO...

Page 3: ...rent of no more than 30 mA Ask your electrician Unplug all devices submerged in the water prior to any contact with aquarium water This device is only approved for inside use and only for aquarium pur...

Page 4: ...with the device The device may not be disposed of in the standard household rubbish It must be professionally disposed WARRANTY The consumer receives for this product a 12 month warranty for material...

Page 5: ...tear parts e g rotor seals Improper handling and use including the use of products from other manufacturers Any kind of damages e g wires of electrical devices Technical changes and modifications to...

Page 6: ...signed for in sump use The unit cannot be used outside the sump Put Nyos TORQ G2 Dock in your sump Please ensure that the bottom of the sump is even This helps ensure that the water can run off evenly...

Page 7: ...w If water exits though the hole the sponge needs to be cleaned The 0 8mm grid is recommended for small grain filter me dia The 1 5mm grid is recommended for lager grain filter media like activated ca...

Page 8: ...a from the top Put the lid back on and turn it to lock position Fig 4 Filling with two filter media TORQ G2 Body 1 0 and Body 2 0 only Hint The media in the upper chamber can be changed easier We ther...

Page 9: ...9 EN 3 Put the insert on the acrylic stick and close the tube by turning the insert 4 Turn the body again and remove the lid Add the second filter media and put the lid back on Fig 5 Fig 5 1 2 3 4...

Page 10: ...n this position the flow rate is zero Plug in the pump By turning the body counter clockwise you can increase the flow rate The flow rate can be read from the scale at the bottom end of the body The f...

Page 11: ...a way that it is virtually bubble free and silent at optimum use This requires a run in period of several days A smear layer is created on the out side of the body so that the water fully moistens th...

Page 12: ...900 l 240 gal 1 800 l 475 gal Zeolite Nyos ZEO Maxium capacity 750 ml 25 fl oz 1 000 ml 34 fl oz 2 000 ml 68 fl oz Tank size up to 300 l 80 gal 400 l 100 gal 800 l 200 gal Usage of two filter media Ph...

Page 13: ...ease flow rate Pump is clogged Clean the pump Use of too much filter media Reduce amount of filter media see table on page 12 Filter media collects at the top filter sponge and clogs it Flow rate is t...

Page 14: ...of the lid Fig 8 Generally speaking however this is not necessary Reducion in pump performance At the time of delivery the pump is set to a maximum per formance of 1 000 l h 264 gph Should you use ve...

Page 15: ...to use detergents The grid of the pump should be cleaned regularly in order to ensure constant performance To do this please remove the pump from the dock The grid of the pump can be removed easily Wh...

Page 16: ...lid 100 Art T BSP_2566 4 Tube 750 ml Art T BSP_4355 Tube 1 000 ml Art T BSP_4362 Tube 2 000 ml Art T BSP_4379 5 Separating grid with acrylic stick 70 0 8 mm Art T BSP_4386 Separating grid with acrylic...

Page 17: ...17 EN EXPLODED DRAWINGS TORQ G2 BODIES TORQ G2 Body 0 75 TORQ G2 Body 2 0 TORQ G2 Body 1 0 4 5 5 6 7 8 8 6 7 4 4 3 3 3 2 2 1 1 2 1 6 7 8...

Page 18: ...r Part No T DSP_Imp 13 Shaft Part No T DSP_2740 14 Bearing Part No T DSP_2757 15 Pump housing with slider Part No T DSP_2764 16 Dock housing Part No T DSP_2771 17 Dock base plate Part No T DSP_2788 18...

Page 19: ...19 EN NOTES...

Page 20: ...yos aquatics Manufactured by Nyos Aquatics GmbH Siemensstr 26 70825 Korntal Muenchingen Germany www nyos info support nyos info Patents pending in EU US and elsewhere TORQ is a protected trademark of...

Reviews: