. These DACs can be set by using the stdm instruction to setup the access
mode. The DAC registers can be loaded with the cp and load instructions. Loading DAC
register values to other registers or DRAM is also possible by means of the cp and store
instructions.
Table 17. Current measurement DACs affectation to microcores
oc_dac_sel_ucX
= '0'
(next channel)
oc_dac_sel_ucX
= '1'
(previous channel)
Microcore
dacsssc
dacossc
dacssoc
dacosoc
dacssoc
dac osoc
Uc0, channel 1 dac1
dac2
dac3
dac4
dac5
dac6
Uc1, channel 1 dac2
dac1
dac4
dac3
dac6
dac5
Uc0, channel 2 dac3
dac4
dac5
dac6
dac1
dac2
Uc1, channel 2 dac4
dac3
dac6
dac5
dac2
dac1
Table 18. Current sense instructions
Set ADC mode
Set DC-DC control mode
Set DAC register mode access
Set current measure operational amplifier gain
Set offset compensation
2.15 Output drivers
The instructions described in this section are used to control the output drivers. Each
high-side and low-side can be turned ON/OFF by all microcores if the output access
registers are configured properly (refer to register 184h to 187h). Low-side and high-side
bias needs to be enabled before using the diagnostics, and can be kept ON during the
application.
It is possible to enable or disable the end-of-actuation mode. In the final phase of an
actuation, while the current in the actuator is decreasing, it is possible to detect when
the current has reached the zero value. In most applications, it is required that the
Vsource threshold for the corresponding HS output is set to zero. This condition can be
automatically enabled and disabled together with the end-of-actuation mode.
Table 19. Output drivers instructions
Enable high-side and low-side bias
Set end-of-actuation mode
Set freewheeling mode
Set single predriver output
Set predriver output shortcuts
Set predriver output slew rate mode
Set measurement function multiplexers (only available on PT2001M)