background image

HOW TO GET STARTED

If the fixture is a new build:

1.   Set gate bias to minimum by turning pot fully clockwise (12 turns). 
2.  Remove JP1 and check drain DC power terminal using an ohmmeter: DC power 

terminal should read a high impedance.

3.  Replace JP1. 

Initial power on:

1.  Mount baseplate onto a heatsink capable of dissipating more than 100 W. 
2.  Terminate RF output with a 50 ohm load capable of dissipating more than 330 W.
3.  Connect RF input to a 50 ohm source with RF off.
4.  Ensure the drain DC is set to 0 V.
5.  Connect ground, drain DC. 
6.  Raise drain DC slowly to 50 Vdc. Current should be 0 A.
7.  Adjust gate bias to desired target current, typically 50-500 mA.
8.  Slowly increment RF input power source not exceeding 1 W. Monitor drain DC 

current and RF output power (typically less than 10 A max at 300 W).

9.  Check drain DC current, RF output power and temperature.

Shutdown:

1.  Shut off RF input power.
2.  Remove drain DC voltage.

QUICK START GUIDE