If no steam or moisture becomes visible in the Oven chamber:
A. Make sure there is water pressure in the supply line to the Solenoid Valve. If there is
pressure from the water source but no pressure at the Bulkhead Inlet Fitting the in-line
Filter may be clogged.
B. Gently tap the Solenoid Valve to free up any sediment that may be causing the Valve to
stick.
C. Remove the Oven Element Cover and check the Water Injection Nozzles to make sure
they are not clogged.
D. Check all wiring connections to the Steam Switch and the Solenoid Valve. If the
Injection Nozzles are clean then the Solenoid Valve or Steam Switch should be replaced
to activate the system.
EXTERNALLY GENERATED STEAM (optional):
XI.
The EXTERNAL STEAM Timer is set but no steam is observed after 2 to
3 minutes:
The EXTERNAL STEAM Generator is operated by activating the Steam Timer on the front
of your unit. This Steam Timer regulates the duration time of the steam injection by
controlling the running time of the Steam Generator. A cold start should produce steam
within 2 or 3 minutes, while a Steam Generator that is still hot from previous use will begin
to produce steam in 15 to 30 seconds. If no steam is noticed after a reasonable length of time:
A. Make sure the water supply to the EXTERNAL STEAM Generator has not been
interrupted (closed valve, clogged filter, pinched supply line, etc.).
B. Make sure that electrical power is being supplied to the separate Steam Generator and
that any Power Switch on the Steam Generator is
ON
.
C. Make sure that voltage is present at the Steam Timer and that all electrical connections
are clean and tight. If the Steam Timer does not count down to "0" it must be replaced.
D. If all of these conditions are met and you still cannot get any steam please refer to the
Trouble–Shooting Guide in the Service Manual provided with your Steam Generator. If
you do not have a separate Service Manual you may call NU–VU®'s Service
Department at (800) 338-9886 and we will try to help you.