  Attach the appropriate nipple (not included) securely into the ports on  

each side of the Housing Head. The inlet and outlet ports are tapered  

(NPT) and require thread seal tape or sealant compound to prevent leakage.  

Be very careful, as over-tightening the threading can split or break the port.  

DO NOT OVER-TIGHTEN.

9

  Securely connect the water supply  

  line inlet & outlet to the nipples in the  

  Housing Head. Softener functionality  

  requires the correct flow direction;  

  make sure water supply inlet pipe  

  is attached to the inlet port.  

  See FIG. 3

10

 Check that the O-ring is properly  

  seated inside the Housing Body.  

  See  FIG. 4

11

 Remove shrink wrap material  

  and packing foam ring, then insert  

  Cartridge into Housing Body.  

  Make sure holes on side of  

  cartridge are located at the top.

12

 Attach the Collar (turn counter - 

  clockwise or right) and use the  

  Wrench provided to securely  

  tighten the Housing Body to the  

  Housing Head.

13

 Turn on the main water supply.  

  Be sure Housing Head is turned  

  to the “Softener” position.

8

Ports are marked  

“IN” and “OUT”

Pressure Relief Valve

O-ring must be properly seated  

on first ridge as shown.

FIG. 4

FIG. 3

PLEASE NOTE: For maximum efficiency, please do not use the system  

immediately. Allow the new cartridge to remain in the housing with  

minimal water flow for one hour. 

Summary of Contents for DPHB

Page 1: ...Installation Guide ...

Page 2: ... hard water buildup that clogs and corrodes water heaters and other plumbing fixtures and appliances What to expect with your nuvoH2O Softener The nuvoH2O softener naturally binds minerals to prevent hard water buildup instead of removing the minerals like old salt based water softeners This mineralized water is healthier and the nuvoH2O system will not change the taste of your water The nuvoH2O s...

Page 3: ... salt based softener Package Contents In addition to the nuvoH2O softener and the Quick Start Cartridge the nuvoH2O softener package also includes a mounting back plate mounting bracket screws and housing wrench Because plumbing standards vary other bushings and connectors are not included Keeping Your System Running Once installed the nuvoH2O requires no additional maintenance other than the semi...

Page 4: ...or 2 or 3 bathrooms and average water use Size 5 x 24 Weight 7 pounds Water flow 12 15 gpm with 1 ports Max pressure 100 PSI 6 8 bar Capacity about 35 000 gallons or up to 6 months Uses 2 x 20 replacement cartridges Item H 2416 or HHP 2516 Built in pressure relief valve FDA NSF approved Manor System Item DPMB For larger homes over 2000 sq ft with 3 or more bathrooms and homes with above average wa...

Page 5: ... PSI RATING 100 6 8 BAR 7 Make sure system is appropriately sized for the intended use Please check system specifications on Page 3 prior to installing unit 8 Remove and discard the foam packing ring and plastic shrink wrapping from around the cartridge and inside Housing before installation 9 Cartridge MUST be inserted properly inside housing body large by pass holes at top 10 If installing a fil...

Page 6: ...ing Panel into the wall stud Another screw attaches the Wall Mounting Panel to the wall stud directly above the right C Bracket screw See FIG 1 4 Remove Housing Head from Housing Body by detaching Collar turn clockwise or left use provided Wrench if necessary 5 Attach Housing Head to the wall by inserting the nipples not included in Housing Head through the side holes in the C Bracket 6 Tighten ni...

Page 7: ... is properly seated inside the Housing Body 9 Remove shrink wrap material and packing foam ring then insert Cartridge into Housing Body Make sure holes on side of cartridge are located at the top See FIG 3 10 Attach the Collar turn counter clockwise or right and use the Wrench provided to securely tighten the Housing Body to the Housing Head 11 Turn on the main water supply Be sure Housing Head is...

Page 8: ... Body may be removed to make it easier to attach the L Bracket Housing Head Assembly to the Mounting Panel 4 Unscrew the Black Top of the Housing Unit This is held together with a single screw in the middle 5 Attach the L Bracket to the Housing Head and secure it with the four screws provided See FIG 1 7 Attach L Bracket to Housing Head with 4 Screws FIG 1 These screws must be securely attached to...

Page 9: ... See FIG 3 10 Check that the O ring is properly seated inside the Housing Body See FIG 4 11 Remove shrink wrap material and packing foam ring then insert Cartridge into Housing Body Make sure holes on side of cartridge are located at the top 12 Attach the Collar turn counter clockwise or right and use the Wrench provided to securely tighten the Housing Body to the Housing Head 13 Turn on the main ...

Page 10: ...sure is released 3 Using the wrench that came with your system turn the blue collar clockwise to the left to loosen the housing from the head of the system CAUTION The housing will be heavy and full of water 4 Remove the spent cartridge Turn it upside down into a sink or tub and let it drain completely The outside of the cartridge can be rinsed with warm water Do not drain the cartridge in a coppe...

Page 11: ...if we can be of any assistance Lifetime Limited Warranty The nuvoH2O Salt Free Water Softeners are so dependable that you can count on enjoying healthy salt free softened water for your lifetime In the unlikely event that you have trouble with your softener nuvoH2O will at its option repair modify or exchange it at no cost to you To qualify for the lifetime warranty you must purchase the product f...

Page 12: ...877 688 6426 nuvowater com ...

Reviews: