Attach the appropriate nipple (not included) securely into the ports on
each side of the Housing Head. The inlet and outlet ports are tapered
(NPT) and require thread seal tape or sealant compound to prevent leakage.
Be very careful, as over-tightening the threading can split or break the port.
DO NOT OVER-TIGHTEN.
9
Securely connect the water supply
line inlet & outlet to the nipples in the
Housing Head. Softener functionality
requires the correct flow direction;
make sure water supply inlet pipe
is attached to the inlet port.
See FIG. 3
10
Check that the O-ring is properly
seated inside the Housing Body.
See FIG. 4
11
Remove shrink wrap material
and packing foam ring, then insert
Cartridge into Housing Body.
Make sure holes on side of
cartridge are located at the top.
12
Attach the Collar (turn counter -
clockwise or right) and use the
Wrench provided to securely
tighten the Housing Body to the
Housing Head.
13
Turn on the main water supply.
Be sure Housing Head is turned
to the “Softener” position.
8
Ports are marked
“IN” and “OUT”
Pressure Relief Valve
O-ring must be properly seated
on first ridge as shown.
FIG. 4
FIG. 3
PLEASE NOTE: For maximum efficiency, please do not use the system
immediately. Allow the new cartridge to remain in the housing with
minimal water flow for one hour.