Section 3
Dual Ceiling Mount Installation
•
Bring one section of the dual ceiling mount casting to the ceiling rod and fasten it to the rod with
the 2” long bolts (P/N 0001311) and cap nuts (P/N 0001312). Tighten the cap nuts just enough
to hold the section in place; they do not need to be fully tightened at this time. Bring an arm
assembly to the Dual mount section and fasten the transformer housing into the extension arm
mounting cavity with two
3
/
8
” long mounting screws (P/N 0001291). Install the other arm
assembly to the section with two more
3
/
8
” long screws. Route the wire and
Molex connector from the ceiling rod into the wire channel as shown in figure 9. Plug the
connector at the end of each transformer housing to the mating Molex connector from the wire
harness. Place each set of wires within the channel area.
Dual Ceiling
Mount Section
Extension Arm Mount
Wire Channel
Wire Harness
Ceiling Rod
FIGURE 8: Wire Harness Positioning
FIGURE 9: Wire Channel
Ceiling Rod
Wire Harness
Wire Channel
Dual Ceiling
Mount Section
Extension Arm Mount