Voyager II
& Open Voyager II
Nitrox System
Nuvair
Page
39
www.nuvair.com
17.5 HP Compressor Filtration
The HP Compressor comes standard with Triplex filtration, utilizing a single Filter Element. Do NOT
use any substitute. Change Filter Element every 60,000 cubic feet of air or Nitrox processing. If the
Nitrox System is operated in high humidity and/or high temperature, Filter Element must be changed
more often. See Appendix for details on Filter Element Life Factors.
1) Shut down the Nitrox System
2) Open Manual Condensate Valves and Filter Pressure Bleed Valve to drain pressure. Leave
Valves open.
3) Unscrew the Filter Canister Cap per the HP Compressor manual.
4) Remove expended Element from Filter Canister.
5) Slide new Element into Canister (
DO NOT drop in
) and reinstall Canister Cap.
6) Close Manual Condensate Valves and Filter Pressure Bleed Valve.
Be sure that all pressure has been relieved from the system prior to opening
any filtration canister. Failure to vent pressure from the system prior to opening
the canister can lead to serious personal injury or death.
Filter Canister Cap
Manual Filter
Pressure
Bleed Valve
Manual
Condensate
Drain Valve
Condensate
Tank
3