Calibrate Oxygen Analyzers as follows:
1) Turn off LP compressor and return LP Feed Air BP Regulator to minimum pressure setting by
turning adjustment knob CCW until it spins freely.
2) Slightly open fill whip valve on HP
Compressor to relieve any
residual pressure, and then, if
desired, insert clean rag in yoke
to act as sound muffler.
3) Adjust fill whip valve so the running HP Compressor maintains 1500-2000 psi (100-140 bar)
outlet
pressure. Air will now be flowing past both Oxygen Analyzers for calibration purposes.
4) Monitor all gauges for proper operating range and check all connections for leaks.
5) Calibrate Oxygen Analyzers while the HP Compressor is pumping air. Refer to the Oxygen
Analyzer manual included with the Nitrox System for details. Note that special calibration
procedures may be required when operating at altitudes above sea level.
♦
Permeate Oxygen Analyzer - Calibrate analyzer so Display reads 20.9%.
♦
Fill Oxygen Analyzer - Calibrate analyzer so Display reads 20.9% to correlate with the Grade E
breathing air present at the Sensor. Different settings may be used depending on location, so
verify your actual ambient conditions and refer to the Oxygen Analyzer manual for details.
Insert Clean Rag
in Fill Whip Yoke
Adjust Fill Whip
Valve to Maintain
Pressure
Optional Sound Muffler
for HP Nitrox Compressor is
available
LP Feed Air BP
Regulator
Adjustment Knob
Summary of Contents for Open Voyager II
Page 1: ...User Manual Voyager II Open Voyager II Nitrox System Rev 03 19...
Page 17: ...Voyager II Open Voyager II Nitrox System Nuvair Page 17 www nuvair com...
Page 46: ...Voyager II Open Voyager II Nitrox System Nuvair Page 46 www nuvair com NOTES...
Page 47: ...Voyager II Open Voyager II Nitrox System Nuvair Page 47 www nuvair com...