Nuvair Open Electric Models
Nuvair Page 26
www.Nuvair.com
13.0 HP Compressor Filtration Active Carbon Filters / Molecular Sieve
The HP Compressor comes standard with Triplex filtration, utilizing a single Filter Element. Do NOT
use any substitute. Change filter elements every 60,000 cubic feet of air pumped. If the compressor
system is operated in high humidity and/or high temperature, filter elements must be changed more
often. See 13.1 for details on filter element life factors.
1) Shut down the Compressor System
2) Open Manual Bleed Drain Valve on filter towers to drain pressure. Leave valve open.
3) Unscrew the Filter Canister Cap.
4) Remove expended Element from Filter Canister.
5) Install New Element place pressure on element to seat the element.
6) Reinstall Cap to Canister.
7) Close Manual Condensate Valve.
Be sure that all pressure has been relieved from the system prior to opening any filtration
canister. Failure to vent pressure from the system prior to opening the canister can lead to
serious personal injury or death. Difficulty turning the filter cap may indicate there still is
pressure in the filter canister.
5
4
3
Filter Canister Caps
Condensate
Tank
Manual Bleed
Drain Valves
HP Filter
Replacement
parts:
X65677
X65247