MCH36 Silent Touch
Nuvair
Page 24
www.Nuvair.com
8.0
Compressor Specifications
Ambient room temperature should never 104
°
F (40
°
C) during operation of the compressor
system. Operation at higher temperatures may lead to system damage and malfunction.
8.1
Unpacking and Installation
•
Please read all information supplied before physically installing the compressor system.
•
Unpack the system and remove from the pallet. Visually inspect the system to make sure there has
been no damage during shipping. If damaged, please call Nuvair to file a damage report. Please take
photos and supply detailed information about the damage.
•
Place the system in a permanent location
allowing a minimum spacing of 39 inches (1 m)
from adjacent walls and inches 59 inches (1.5
m) from ceiling (Figure 14).
•
Select a location where ambient room
temperature complies with stated requirements.
•
Make sure the installation space is well
ventilated.
8.2
Air Intake Extension Connection
If the compressor is installed in an area without the
necessary ventilation requisites described in section
8.1, it will be necessary to install an air intake extension
leading in from outdoors or a place with the required
ventilation requisites.
Compressor Models
Coltri MCH36
Charging Rate
Filling an 80 cu ft tank from 500 psi
227 SCFM (764 L/min)
Total Charging Rate: 22.5 SCFM (637 L/min)
Maximum Operating Pressure
6000 psi (414 bar)
Pumping Unit RPM
1250
Number of Stages
4
Lubrication
Pressure Lubrication, capacity 1.1 gal (4 L)
Oil Pressure
cold
routine use
minimum pressure
58 psi (4 bar)
21.75 psi (1.5 bar)
14.5 psi (1 bar)
Air Quality
Grade E
Figure 14. Illustration of proper positioning.