Electrical Connection
WARNING
Connection must only be carried out by suitably trained, qualified and skilled
engineers, in accordance with all regional and local electrical codes.
The appliances are electrically rated for a 230 V or 400 V, 50 Hz electrical supply.
The equipment is designed to be installed as a cord connected device, 13 A single phase, 16 A single phase,
16 A 3 phase and 32 A single phase supplies for the applicable unit. A 13 A plug top, 16 A single phase
commando, 16 A 3 phase commando, or a 32 A single phase commando cord set will be fitted to the
corresponding unit.
The equipment must be connected to a branch circuit protected grounded supply.
Each unit must have its own dedicated power supply.
Note: For electrical ratings of the unit, refer to the electrical rating plate located on the side of the
control panel. An example is shown below.
It is highly recommended to provide the equipment with an accessible means of isolation external to the
equipment, i.e. a wall isolator switch.
Electrical Ratings
Total Power
Model Width
Countertop
3 Tier Unit
4 Tier Unit
5 Tier Unit
400 mm
1300 W
2100 W
2700 W
N/A
600 mm
1300 W
2100 W
2700 W
3400 W
1000 mm
2700 W
4100 W
5500 W
6900 W
WARNING
For all types of installation, ensure that the mains lead is in a safe position. Under no
circumstances should any electrical cables or power points be installed directly in contact
with any part of the unit or pose a risk to safety.
If the mains power lead becomes damaged, isolate the equipment and remove from
service immediately until a replacement is fitted.