background image

 

IBS 40002210 

 
 

OPERATION MANUAL 

 

Flexeserve Zone® 

 

FXZNA10N2S51 │ FXZNA10S3C51 │ FXZNA10S3C53 │ FXZNA10S3S53 │ FXZNA10S4C51 │ FXZNA10S4C53 │ FXZNA10S4S51 

FXZNA10S4S53 │ FXZNA10S5C51 │ FXZNA10S5S51 │ FXZNA40N2S51│ FXZNA40S3C51 │ FXZNA40S3S51 │ FXZNA40S4C51 

FXZNA40S4C53 │ FXZNA40S4S51 │ FXZNA60N2S51 │ FXZNA60S3C51 │ FXZNA60S3S51 │ FXZNA60S4C51 │ FXZNA60S4S51 

FXZNA60S5C51 │ FXZNA60S5C53 │ FXZNA60S5S51 

 

 

 

Customer Support

 [

t

] +44 (0)1455 638300 

(V13 January 2019) 

 
 

Summary of Contents for Flexeserve Zone FXZNA10N2S51

Page 1: ...S4C51 FXZNA10S4C53 FXZNA10S4S51 FXZNA10S4S53 FXZNA10S5C51 FXZNA10S5S51 FXZNA40N2S51 FXZNA40S3C51 FXZNA40S3S51 FXZNA40S4C51 FXZNA40S4C53 FXZNA40S4S51 FXZNA60N2S51 FXZNA60S3C51 FXZNA60S3S51 FXZNA60S4C51...

Page 2: ...fications 6 Installation 10 Positioning 11 Moving 11 Electrical Connection 12 Equipment Configuration 13 Power On Off 14 Switching On 15 Switching Off 17 Operation 18 Display and Merchandising 19 Prod...

Page 3: ...result of a constant commitment to development and improvement it may be the case that your equipment deviates in detail from what is described in this manual The following instructions are only inten...

Page 4: ...f lifting and moving HOT SURFACE To indicate that the marked item can be hot and should not be touched without taking care INFORMATION Information provided for trained and skilled operators only MAINT...

Page 5: ...power cable for damage If damaged disconnect and isolate the Flexeserve Zone unit If the glass display shelf is cracked isolate the Flexeserve Zone unit and remove from service Ensure that there are...

Page 6: ...nimum of 85 C air temperature The Flexeserve Zone Countertop display units are provided with two zones shelves The Flexeserve Zone floor standing display units are provided with three to five zones sh...

Page 7: ...9 Overall Dimensions 3 Tier Unit End Panels Width A Depth B Height C Weight Curved 450 mm 830 mm 1520 mm 132 kg Square 855 mm 136 kg Curved 556 mm 830 mm 1520 mm 145 kg Square 855 mm 148 kg Curved 975...

Page 8: ...9 Overall Dimensions 4 Tier Unit End Panels Width A Depth B Height C Weight Curved 450 mm 865 mm 1865 mm 156 kg Square 855 mm 159 kg Curved 556 mm 865 mm 1865 mm 217 kg Square 855 mm 220 kg Curved 975...

Page 9: ...3 January 2019 Overall Dimensions 5 Tier Unit End Panels Width A Depth B Height C Weight Curved 556 mm 873 mm 1970 mm 220 kg Square 556 mm 855 mm 1970 mm 223 kg Curved 975 mm 873 mm 1970 mm 340 kg Squ...

Page 10: ...arges Deliveries must only be signed off if they are in a satisfactory condition Ensure that safe manual handling practices are employed at all times The unit should be lifted into position using the...

Page 11: ...n The equipment must be kept in the vertical orientation at all times Once the unit is placed in the desired location it should be prevented from being moved The Flexeserve Zone floor standing units 3...

Page 12: ...d supply Each unit must have its own dedicated power supply Note For electrical ratings of the unit refer to the electrical rating plate located on the side of the control panel An example is shown be...

Page 13: ...lycarbonate risers fitted to ensure safe and correct operation CAUTION The unit will not operate correctly without the front risers in the correct position Slide signage into the ticket edges Close th...

Page 14: ...he display unit Set the switch isolator to I to apply power to the equipment and set to O to power off 2 Tier Units Example 400 and 600 mm 3 4 and 5 Tier Units Example 1000 mm 3 4 and 5 Tier Units Exa...

Page 15: ...e equipment it is the operator s responsibility to visually inspect the equipment to ensure that there is no damage that may compromise safety Switch on the zone power switch and the display will illu...

Page 16: ...the heating enable disable button and the display will read OFF Visually you will see that the fan has stopped rotating and there is no air circulating around the zone The zone is now in ambient mode...

Page 17: ...y be carried out when sufficiently cooled and with the mains supply isolated To switch off the respective zone set the zone power switch to O central position When the zone is turned off the temperatu...

Page 18: ...he appropriate zone controller and is for indication only Do NOT use this as a reference regular probing of the product temperatures is to be performed The minimum and maximum set point values have be...

Page 19: ...s trading to ensure the core temperature of the product is above the legal holding temperature of 63 C Refer to in house operations manual for product probing instructions It is beneficial for the ho...

Page 20: ...RNING If the surface glass is cracked or damaged discontinue use Do NOT use excessive amounts of water Do NOT clean the equipment with high pressure cleaners jets of hot water or high pressure steam A...

Page 21: ...he temperature to drop Relocate the equipment to a more suitable location If this is not possible raise the temperature settings call Customer Support as an Engineer is required to do this Set tempera...

Page 22: ...ion of fault Disposal of this Equipment WASTE OF ELECTRICAL AND ELECTRONIC EQUIPMENT Penalties may be applicable for incorrect disposal of waste in accordance with national legislation This product sh...

Page 23: ...ustomer Support t 44 0 1455 638300 Enquiries t 44 0 1455 638300 Customer Support e customer support nuttalls co uk Enquiries e info flexeserv com Customer Support The Alan Nuttall Partnership Ltd Orch...

Reviews: