5.  Position fan/damper assembly so that the inlet face of 

the radiation damper is flush with the finished surface of 

the ceiling. Fasten fan/damper assembly to the building 

structure by driving #10 (M5) minimum sheet metal 

screws or #8d minimum nails (hardware not provided) 

through the fan mounting brackets and into the ceiling 

joists. There must be a minimum of two fasteners on 

each of two opposite sides. Ceiling opening must be no 

larger than the inlet opening of the damper.

6. 

New Construction

A housing mask has been provided to keep construction 

dust, drywall spray, paint, etc. from damaging the 

radiation damper or blower assembly.
a) Bend up the small tab of the mask.
b) Tuck the opposite side of the mask under one of the 

damper’s grille mounting ears and push mask up into 

damper housing.

Remove mask before installing grille or operating fan.

Attach the metal grille over the inlet face of the radiation 

damper using (2) #8-18 x 0.812” sheet metal screws 

(provided). 

WARNOCK HERSEY LISTING 
INCLUDES DAMPER ONLY. IT 

DOES NOT INCLUDE EXHAUST 

FAN. DAMPERS MAY BE USED 

WITH UL LISTED FAN MODELS 

NOTED.

16” OR 24” ON CENTER

FASTENER

FAN

MOUNTING 

BRACKET

GRILLE

GRILLE SCREW

CEILING

DAMPER

WOOD 

FRAMING 

MEMBER 

OR JOIST

WARNOCK HERSEY LISTED

Summary of Contents for RDJ1

Page 1: ...ct connector to ventilation fan housing Fig 1 1 Snap metal duct connector onto housing Make sure that tabs on the duct connector lock into the slots on the housing Damper flap hinge should be position...

Page 2: ...M4 sheet metal screws or 1 4 6mm diameter bolts with nuts hardware not provided to mechanically fasten it to the structure Position fan damper assembly so that the inlet face of the radiation damper...

Page 3: ...nstruction A housing mask has been provided to keep construction dust drywall spray paint etc from damaging the radiation damper or blower assembly a Bend up the small tab of the mask b Tuck the oppos...

Page 4: ...an NuTone faulty installation or installation contrary to recommended installation instructions The duration of any implied warranty is limited to the one year period as specified for the express warr...

Page 5: ...et le raccord de conduit sur le bo tier du ventilateur Fig 1 1 Enclenchez le raccord de conduit m tallique sur le bo tier Assurez vous que les ergots du raccord de conduit s ins rent dans les fentes d...

Page 6: ...M4 ou des boulons et des crous de 1 4 po 6 mm de diam tre afin de fixer les supports la charpente Positionnez l assemblage ventilateur clapet de sorte que l entr e du clapet anti rayonnement affleure...

Page 7: ...rot ger le clapet anti rayonnement et le ventilateur de la poussi re de construction du pl tre de la peinture etc a Repliez vers le haut la petite languette du masque b Coincez l autre extr mit du mas...

Page 8: ...tion contraire aux instructions recommand es La dur e de toute garantie tacite est limit e la p riode d un an stipul e pour la garantie expresse Certains territoires ou provinces interdisant de limite...

Page 9: ...1 Conecte a presi n el conector del conducto met lico a la cubierta Aseg rese de que las leng etas del conector de conductos queden fijas en las ranuras de la cubierta La bisagra de la aleta del regu...

Page 10: ...no se incluyen los herrajes para sujetarlo mec nicamente a la estructura Coloque el conjunto de ventilador y regulador de tal modo que la cara de entrada del regulador de radiaci n quede al ras con l...

Page 11: ...n roc os de yeso pintura etc en el regulador de radiaci n o conjunto del ventilador los cuales podr an da arlo a Doble hacia arriba la aleta peque a de la cubierta protectora b Meta el lado opuesto d...

Page 12: ...Broan NuTone instalaci n defectuosa o instalaci n contraria a las instrucciones de instalaci n recomendadas La duraci n de cualquier garant a impl cita se limita a un per odo de un a o como se especif...

Reviews: