NuTone QuieTTest QT200 Installation Instructions Manual Download Page 1

INSTALLATION INSTRUCTIONS

READ & SAVE THESE INSTRUCTIONS

WARNING

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR
INJURY TO PERSONS, OBSERVE THE FOLLOWING:

1. Use this unit only in the manner intended by the manufacturer. If

you have questions, contact the manufacturer at the address or
telephone number listed in the warranty.

2. Before servicing or cleaning unit, switch power off at service

panel and lock service disconnecting means to prevent power
from being switched on accidentally. When the service
disconnecting means cannot be locked, securely fasten a
prominent warning device, such as a tag, to the service panel.

3. Installation work and electrical wiring must be done by qualified

personnel in accordance with all applicable codes and
standards, including fire-rated construction.

4. Sufficient air is needed for proper combustion and exhausting of

gases through the flue (chimney) of fuel burning equipment to
prevent back drafting. Follow the heating equipment manufacturer's
guideline and safety standards such as those published by the
National Fire Protection Association (NFPA), and the American
Society for Heating, Refrigeration and Air Conditioning
Engineers (ASHRAE), and the local code authorities.

5. When cutting or drilling into wall or ceiling, do not damage

electrical wiring and other hidden utilities.

6. Ducted fans must always be vented to the outdoors.
7. If this unit is to be installed over a tub or shower, it must be

marked as appropriate for the application.

8. Never place a switch where it can be reached from a tub or shower.
9. When applicable local regulations comprise more restrictive

installation and/or certification requirements, the aforementioned
requirements prevail on those of this document and the installer
agrees to conform to these at his own expenses.

10. When performing installation, servicing or cleaning this unit, it is

recommended to wear safety glasses and gloves.

CAUTION

For general ventilating use only. Do not use to exhaust hazardous
or explosive materials and vapors.

INSTALLATION INSTRUCTIONS

Suitable for use with solid state speed controls

Uses standard 3¼" x 10" ducting

Designed for ceiling installation

Do not mount over bathtub or shower stall enclosure

Not for use in kitchens

The ventilator consists of the housing, mounting brackets, junction box,
power unit/blower assembly, damper section and grille assembly

FAN MUST NOT BE INSTALLED IN A CEILING THERMALLY
INSULATED TO A VALUE GREATER THAN R-40.

FOR BEST RESULTS

When installing the ventilator in a new construction site, install the
housing during the rough-in construction of the building. The power
unit and grille should be installed after the finished ceiling is in place.

To install the ventilator in an existing building, an accessible area
(attic or crawl space) is required from above the planned location.

QuieTTest

®

Twin Blower Ventilator

MODELS: QT200 & QT300

For Ceiling Installation

BD0009

BH00

3

9

INSTALLATION
IN A NEW CONSTRUCTION SITE

PREPARATION

CAUTION:

When handling the power unit do not reach in the end

openings and bend the blower wheels.

Refer to Figure 1.

1. Remove power unit from housing assembly.

(a) If necessary, unplug power plug from the connector.
(b) Loosen wing nut on hanger rods that hold the power unit.
(c) Unfasten hanger rods from slots and remove power unit.
(d) Set power unit aside until needed.

2. 

Refer to Figure 2.

Remove one of the wiring knockouts from

the housing.

3. The ventilators can be ducted for either vertical or horizontal

discharge.

4. 

Refer to Figure 3.

Mount 3¼" x 10" damper section on top of

housing for vertical discharge or on the side of housing for
horizontal discharge with two screws (included).

FIGURE 1

FIGURE 2

POWER
UNIT

ROOF CAP

VERTICAL
DISCHARGE

3¼" x 10"
DUCT

KNOCKOUTS

FAN
HOUSING

HORIZONTAL
DISCHARGE

WALL CAP

POWER
CONNECTOR

SLOTS

WING NUT,
HANGER ROD

HANGER
ROD

85669000C

Register your product online

at www.nutone.ca

1

Summary of Contents for QuieTTest QT200

Page 1: ...ning this unit it is recommended to wear safety glasses and gloves CAUTION For general ventilating use only Do not use to exhaust hazardous or explosive materials and vapors INSTALLATION INSTRUCTIONS Suitable for use with solid state speed controls Uses standard 3 x 10 ducting Designed for ceiling installation Do not mount over bathtub or shower stall enclosure Not for use in kitchens The ventilat...

Page 2: ...s 1 Refer to Figure 5 Loosen screws and remove junction box 2 Run 120 VAC supply wiring with ground through switch box to knockout in ventilator housing and secure with box connector 3 Refer to Figure 6 Connect supply wires to ventilator wires BLACK to BLACK WHITE to WHITE Connect ground wire to GREEN ground lead 4 Reinstall junction box and tighten screws 5 Connect supply wire to switch NOTE Swit...

Page 3: ...led or that the area is sufficient for proper mounting 2 Wiring can be run to the planned location 3 No wiring or other obstruction will interfere with the installation INSTALLATION FROM ACCESSIBLE AREA ABOVE USING HEADERS 1 From below the installation site drill a small hole in ceiling at the planned location 2 Locate hole in attic or crawl space 3 In attic or crawl space mark ceiling for cutout ...

Page 4: ...tion instructions The duration of any implied warranty is limited to the one year period as specified for the express warranty BROAN NUTONE CANADA S OBLIGATION TO REPAIR OR REPLACE AT BROAN NUTONE CANADA S OPTION SHALL BE THE PURCHASER S SOLE AND EXCLUSIVE REMEDY UNDER THIS WARANTY BROAN NUTONE CANADA SHALL NOT BE LIABLE FOR INCIDENTAL CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTI...

Page 5: ...de sécurité lors de l installation de l entretien ou de la réparation de cet appareil ATTENTION Pour ventilation générale seulement Ne l utilisez pas pour évacuer des vapeurs ou des matières dangereuses ou explosives DIRECTIVES D INSTALLATION Compatible avec une commande de vitesse à semi conducteurs Se raccordent à un conduit standard de 3 po x 10 po Conçus pour une installation au plafond Ne pas...

Page 6: ...à la terre à partir du boîtier de l interrupteur jusqu à la boîte de jonction au travers d un serre fils installé dans l ouverture préamorcée 3 Voir Figure 6 Raccorder les fils d alimentation aux fils du ventilateur le NOIR avec le NOIR le BLANC avec le BLANC Reliez le fil de mise à la terre au fil VERT de mise à la terre du ventilateur 4 Remettre en place la boîte de jonction et serrer ses vis 5 ...

Page 7: ...installation adéquate 2 Le câble puisse être acheminé jusqu à l emplacement choisi 3 Aucun câblage ou autre construction ne gêne l installation INSTALLATION PAR L ESPACE ACCESSIBLE AU DESSUS EN UTILISANT DES CHEVÊTRES 1 Percer un petit trou par en dessous de l emplacement prévu du ventilateur 2 Repérer le trou dans le grenier ou sous les combles 3 Depuis le grenier ou sous les combles tracer la dé...

Page 8: ... est limitée à une période de un an telle qu il est spécifié pour la garantie exprimée L ENGAGEMENT DE BROAN NUTONE CANADA DE RÉPARER OU DE REMPLACER AU CHOIX DE BROAN NUTONE CANADA DOIT ÊTRE LA SEULE OBLIGATION EXCLUSIVE EN VERTU DE CETTE GARANTIE BROAN NUTONE CANADA NE DOIT PAS ÊTRE TENUE RESPONSABLE DES DOMMAGES DIRECTS INDIRECTS OU SPÉCIAUX SURVENANT À CAUSE DE L UTILISATION OU DE LA PERFORMAN...

Reviews: