background image

Page 3

MODELS   QTXE080 • QTXEN080 • QTXE090C • QTXE110 • QTXEN110 • QTXE1102

2. Attach 

damper/duct 

connector.

 

Snap damper / 

duct connector 

onto housing. 

Make sure con-

nector is flush with 

top of housing and 

damper flap falls 

closed.

3. Install 

6-inch 

round duct-

work.

 

Connect 6-inch 

round ductwork 

to damper / duct 

connector. Run 

ductwork to a 

roof cap or wall 

cap. Tape all 

ductwork con-

nections to make 

them secure and air tight.

INSTALL HOUSING & DUCT

 

1a. Mount 

housing to 

joist or 

I

-joist.

 

Use a pliers to bend 

housing 

TABS

 out 

to 90

0

. Hold housing 

in place so that 

the housing tabs 

contact the bottom 

of the joist. The 

housing mounts 

with four (4) screws 

or nails. Screw or 

nail housing to joist 

through lowest 

holes in each 

mounting flange,  

then through 

highest holes. 

NOTE: Mounting to 

I

-JOIST

 (shown) 

requires use 

of 

SPACERS

 

(included) between 

the highest hole 

of each mounting 

flange and the 

I

-joist.

SPACER

(use for mounting to I-Joist)

I

-JOIST

TABS

1b. Mount housing anywhere between 

trusses, joists, or 

I

-joists using hanger 

bars.

 

Sliding hanger bars are provided to allow for accurate posi-

tioning of housing anywhere between framing. They can be 

used on all types of framing (

I

-joist, standard joist, and truss 

construction) and span up to 24”.

Attach the MOUNTING CHANNELS to the housing using the 

SCREWS supplied. Make sure TABS face “up” as shown. Use 

the set of channel mounting holes (marked “STD”) to mount the 

housing flush with the bottom of the drywall. Use the other set 

of holes (not marked) to mount the housing flush with the top of 

the drywall.

OR

HANGER

BAR (4)

SCREWS (4)

TAB

 

Extend HANGER BARS to the width of the framing.

  Hold ventilator in place with the hanger bar tabs wrapping 

around the BOTTOM EDGE OF THE FRAMING.

 

NAIL ventilator to framing or fasten with screws (not provided) 

through HOLES near nails.

 

*

 To ensure a noise-free mount: Secure hanger bars together 

with  SCREWS or use a pliers to crimp mounting channels 

tightly around hanger bars.

HOLE FOR OPTIONAL 

SCREW MOUNTING (4)

STD

MOUNTING

CHANNEL (2)

NAIL (4)

BOTTOM EDGE 

OF FRAMING

*

 

SCREW (2)

Summary of Contents for QTXE080

Page 1: ...into wall or ceiling do not damage electrical wiring and other hidden utilities 6 Ducted fans must always be vented to the outdoors 7 Acceptable for use over a tub or shower when connected to a GFCI G...

Page 2: ...possible for best performance and avoid installing the fan with smaller ducts than recommended Insulation around the ducts can reduce energy loss and inhibit mold growth Fans installed with existing...

Page 3: ...st I JOIST TABS 1b Mount housing anywhere between trusses joists or I joists using hanger bars Sliding hanger bars are provided to allow for accurate posi tioning of housing anywhere between framing T...

Page 4: ...sert them into slots on each side of hous ing 7 Push grille against ceiling 5 Finish ceiling Install ceiling material Cut out around housing 4 Connect electrical wiring Run 120 VAC house wiring to ins...

Page 5: ...eurs canalis s doivent toujours rejeter l air l ext rieur 7 Cet appareil peut tre install au dessus d une enceinte de baignoire ou de douche s il est branch sur un circuit de d rivation prot g par un...

Page 6: ...T RIAU DU PLAFOND PLANIFICATION DE L INSTALLATION Les conduits allant de ce ventilateur jusqu l ext rieur de l habitation ont une grande influence sur le d bit d air le bruit du ventilateur et sa cons...

Page 7: ...ez le bo tier n importe o entre les fermes solives ou solives en I avec les barres de suspension Les barres de suspension fournies permettent de positionner avec pr cision le bo tier n importe o entre...

Page 8: ...d Coupez le autour du bo tier 4 Branchement du c blage lectrique Acheminez un fil de 120 VCA jusqu au lieu d installation Fixez le fil la plaque de c blage avec le connecteur appropri homologu UL Conn...

Page 9: ...rtar o perforar a trav s de la pared o del cielo raso no da e el cableado el ctrico ni otros servicios ocultos 6 Los ventiladores con conductos deben siempre conectarse hacia el exterior 7 Es aceptabl...

Page 10: ...te instalar el ventilador con conductos menores que los recomendados El aislamiento alrededor de los conductos puede reducir la p rdida de energ a e inhibir el de sarrollo de moho Los ventiladores ins...

Page 11: ...uego de orificios de montaje del canal marcados como STD para montar la cubierta al ras con la parte inferior de la tablarroca Utilice el otro juego de orificios sin marca para montar la cubierta al r...

Page 12: ...a cubierta 7 Empuje la rejilla contra el cielo raso 5 Termine el cielo raso Instale el material del cielo raso Recorte alrededor de la cubierta 4 Conecte los cables el ctricos Extienda el cableado de...

Reviews: