WARNING  

  

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR 
INJURY TO PERSONS, OBSERVE THE FOLLOWING:

1.  Use this unit only in the manner intended by the manufacturer. 

If you have questions, contact the manufacturer at the address 
or telephone number listed in the warranty.

2.  Before servicing or cleaning unit, switch power off at service 

panel and lock the service disconnecting means to prevent 
power from being switched on accidentally. When the service 
disconnecting means cannot be locked, securely fasten a 
prominent warning device, such as a tag, to the service panel.

3.  Installation work and electrical wiring must be done by qualified 

personnel in accordance with all applicable codes and standards, 
including fire-rated construction codes and standards.

4.  Sufficient air is needed for proper combustion and exhausting of 

gases through the flue (chimney) of fuel burning equipment to 
prevent backdrafting. Follow the heating equipment manufacturer’s 
guideline and safety standards such as those published by the 
National Fire Protection Association (NFPA), and the American 
Society for Heating, Refrigeration and Air Conditioning Engineers 
(ASHRAE), and the local code authorities.

5. When cutting or drilling into wall or ceiling, do not damage 

electrical wiring and other hidden utilities.

6.  Ducted fans must always be vented to the outdoors.

7.  Acceptable for use over a tub or shower when connected to 

a GFCI (Ground Fault Circuit Interrupter) - protected branch 
circuit (ceiling installation only).

8.  This unit must be grounded

9.  When applicable local regulations comprise more restrictive 

installation and/or certification requirements, the aforementioned 
requirements prevail on those of this document and the installer 
agrees to conform to these at his own expenses.

10. When performing installation, servicing or cleaning this unit, it 

is recommended to wear safety glasses and gloves.

CAUTION  

!

1.  For general ventilating use only. Do not use to exhaust 

hazardous or explosive materials and vapors.

2. This product is designed for installation in ceilings up to a 

12/12 pitch (45 degree angle). Duct connector must point up. 
DO NOT MOUNT THIS PRODUCT IN A WALL.

3.  To avoid motor bearing damage and noisy and/or unbalanced 

impellers, keep drywall spray, construction dust, etc. off power 
unit.

4.  Please read specification label on product for further information 

and requirements.

READ AND SAVE THESE INSTRUCTIONS

CLEANING & MAINTENANCE

WARRANTY

Installer: Leave this manual with the homeowner.

For quiet and efficient operation, long life, and attractive 
appearance - lower or remove grille and vacuum interior of unit 
with the dusting brush attachment.

The motor is permanently lubricated and never needs oiling. If the 
motor bearings are making excessive or unusual noises, replace 
the blower assembly (includes motor and impeller).

OPERATION

Use an on/off switch or speed control to operate this ventilator. See 
“Connect Wiring” for details. 

QTREN SERIES
QUIET VENTILATION FAN

BROAN-NUTONE CANADA INC.

THREE-YEAR LIMITED WARRANTY

Broan-NuTone Canada warrants to the original consumer purchaser of its products that 
such products will be free from defects in materials or workmanship for a period of three 
(3) years from the date of original purchase. THERE ARE NO OTHER WARRANTIES, 
EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED WARRANTIES 
OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.

During this three-year period

, Broan-NuTone Canada will, at its option, repair or 

replace, without charge, any product or part which is found to be defective under 
normal use and service.
THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS OR 
TUBES, BULBS OR BATTERIES, FILTERS, DUST, ROOF CAPS, WALL CAPS AND 
OTHER ACCESSORIES FOR DUCTING. This warranty does not cover (a) normal 
maintenance and service or (b) any products or parts which have been subject 
to misuse, negligence, accident, improper maintenance or repair (other than by 
Broan-NuTone Canada or an authorized representative), faulty installation or installation 
contrary to recommended installation instructions.
The duration of an implied warranty is limited to the three-year period as specified for 
the express warranty.
BROAN-NUTONE CANADA’S OBLIGATION TO REPAIR OR REPLACE, AT 
BROAN-NUTONE CANADA’S OPTION, SHALL BE THE PURCHASER’S SOLE AND 
EXCLUSIVE REMEDY UNDER THIS WARRANTY. BROAN-NUTONE CANADA SHALL 
NOT BE LIABLE FOR INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES 
ARISING OUT OF OR IN CONNECTION WITH PRODUCT USE OR PERFORMANCE. 
This warranty supersedes all prior warranties.
To qualify for warranty service, you must (a) notify Broan-NuTone Canada at the address or 
telephone number stated below, (b) give the model number and part identification and 
(c) describe the nature of any defect in the product or part. At the time of requesting 
warranty service, you must present evidence of the original purchase date.

Date of Installation 

 

Builder or Installer

Model Number and Product Description

IF YOU NEED ASSISTANCE OR SERVICE

For the location of your nearest Broan-NuTone Canada Inc. dealer:

Dial Toll Free:

 

1-888-882-7626

Please be prepared to provide:

Product model number • Date and proof of purchase • The nature of the difficulty

Broan-NuTone Canada Inc.

1140 Tristar Drive, Mississauga, Ontario L5T 1H9

BB0007

Register your product 

online at www.nutone.ca

Summary of Contents for QTREN090C

Page 1: ...ive appearance lower or remove grille and vacuum interior of unit with the dusting brush attachment The motor is permanently lubricated and never needs oiling If the motor bearings are making excessiv...

Page 2: ...r line voltage and appropriate power cable H0002A Housing mounted anywhere between I joists using hanger bars Housing mounted to joists Housing mounted anywhere between joists using hanger bars Housin...

Page 3: ...housing anywhere between trusses joists or I joists using hanger bars Sliding hanger bars are provided to allow for accurate positioning of housing anywhere between framing They can be used on all ty...

Page 4: ...ERVICE NOTE To remove Blower Assembly Unplug motor 6 Remove screw 4 from motor plate flange Find the single TAB on the motor plate located next to the receptacle Push up near motor plate tab while pus...

Page 5: ...vie ainsi qu une belle apparence abaisser ou enlever la grille puis nettoyez l int rieur de l appareil l aide d un aspirateur muni de la brosse pousseter Le moteur est lubrifi vie Aucune lubrification...

Page 6: ...IVE DE PLAFOND BARRES DE SUSPENSION s tirent jusqu 24 po Bo tier mont n importe o entre des solives l aide de barres de suspension Bo tier mont n importe o entre des poutres triangul es l aide de barr...

Page 7: ...s PATTES soient vers le haut tel qu il est illustr Utiliser l ensemble des trous de montage marqu s STD pour fixer le bo tier ras avec le mat riau du plafond Utiliser l autre ensemble de trous pour fi...

Page 8: ...pour fixer le fil d alimentation la plaque de branchement Brancher les fils tel qu il est illustr dans les sch mas ci dessus NOTE POUR SERVICE Pour enlever l ensemble ventilateur D brancher le moteur...

Reviews: