MODEL   QTRE090FL

5. Connect electrical wiring.

Run 120 VAC house wiring to installation location. Use
proper UL approved connector to secure house wiring to
wiring plate. Connect wires as shown in wiring diagrams.

CONNECT WIRING

3. Attach

damper/duct
connector.

Snap damper /
duct connector
onto housing.
Make sure
connector is flush
with top of
housing and
damper flap falls
closed.

4. Install

4-inch
round
ductwork.

Connect 4-inch
round ductwork
to damper / duct
connector. Run
ductwork to a
roof cap or wall
cap. Tape all
ductwork connections to make them secure and air tight.

INSTALL HOUSING & DUCT

1. Bend

housing
tabs.

Use a pliers to
bend housing

TABS

 out to 90

0

.

2. Mount

housing to
joist.

Hold housing in
place so that the
housing tabs
contact the
bottom of the
joist. The housing
mounts with four
(4) screws or
nails. Screw or nail housing to joist through lowest holes in
each mounting flange,  then through highest holes. NOTE:
Mounting to 

I-JOIST

 (shown) requires use of 

SPACERS

(included) between the highest hole of each mounting
flange and the I-joist.

SPACER

(use for mounting to I-

Joist)

I-JOIST

TABS

INSTALL GRILLE

6. Finish ceiling.

Install ceiling material. Cut out around housing.

7. Attach grille

to housing.

Squeeze grille
springs and insert
them into slots on
each side of
housing.

Summary of Contents for QTRE090FL

Page 1: ...lubricated and never needs oiling If the motor bearings are making excessive or unusual noises replace the motor with the exact service motor The impeller should also be replaced OPERATION The fan lig...

Page 2: ...sing mounted to truss PLAN THE INSTALLATION ROOF CAP 4 IN ROUND ELBOW 4 IN ROUND DUCT WALL CAP Purchase separately The unit will operate most quietly and efficiently when located where the shortest po...

Page 3: ...s to make them secure and air tight INSTALL HOUSING DUCT 1 Bend housing tabs Use a pliers to bend housing TABS out to 900 2 Mount housing to joist Hold housing in place so that the housing tabs contac...

Page 4: ...W Fluorescent 16 97016864 Ballast Assembly 17 99260423 Nut Hex 8 32 2 req d 18 99111293 Spacer 2 supplied SERVICE NOTE To remove Blower Assembly Unplug motor 7 Remove screw 4 from motor plate 9 flange...

Page 5: ...apariencia atractiva baje o retire la rejilla y aspire el interior de la unidad con el accesorio del cepillo para sacudir polvo El motor est permanentemente lubricado y nunca necesitar aceite Si los c...

Page 6: ...erta en una armadura PLANIFICACI N DE LA INSTALACI N TAPA DE TECHO CODO REDONDO DE 4 PULG CONDUCTO REDONDO DE 4 PULG TAPA DE PARED Se compran por separado El ventilador funcionar con m s eficacia y me...

Page 7: ...ones de los conductos para fijarlas y hacerlas herm ticas al aire 3 Acople el conectador del regulador de tiro conducto Conecte a presi n el conectador del regulador de tiro conducto en la cubierta As...

Page 8: ...pecificar el n mero de la pieza no el n mero de la clave 8 Empuje la rejilla contra el cielo raso 10 Instale las bombillas Se incluye una bombilla fluorescente Compre una bombilla incandescente para l...