background image

Page 2

MODEL   QTRE090FL

TYPICAL INSTALLATIONS

Housing mounted to I-joists.

Use I-joist spacer block (provided).

Housing mounted to joists.

Housing mounted to truss.

PLAN THE INSTALLATION

ROOF CAP 

*

4-IN. ROUND

ELBOW 

*

4-IN. ROUND

DUCT 

*

WALL

CAP 

*

*

 Purchase

separately

The unit will operate most quietly and efficiently when located
where the shortest possible duct run and minimum number of
elbows will be needed.
Plan to supply the unit with proper line voltage and appropriate
power cable.

Summary of Contents for QTRE090FL

Page 1: ...lubricated and never needs oiling If the motor bearings are making excessive or unusual noises replace the motor with the exact service motor The impeller should also be replaced OPERATION The fan lig...

Page 2: ...sing mounted to truss PLAN THE INSTALLATION ROOF CAP 4 IN ROUND ELBOW 4 IN ROUND DUCT WALL CAP Purchase separately The unit will operate most quietly and efficiently when located where the shortest po...

Page 3: ...s to make them secure and air tight INSTALL HOUSING DUCT 1 Bend housing tabs Use a pliers to bend housing TABS out to 900 2 Mount housing to joist Hold housing in place so that the housing tabs contac...

Page 4: ...W Fluorescent 16 97016864 Ballast Assembly 17 99260423 Nut Hex 8 32 2 req d 18 99111293 Spacer 2 supplied SERVICE NOTE To remove Blower Assembly Unplug motor 7 Remove screw 4 from motor plate 9 flange...

Page 5: ...apariencia atractiva baje o retire la rejilla y aspire el interior de la unidad con el accesorio del cepillo para sacudir polvo El motor est permanentemente lubricado y nunca necesitar aceite Si los c...

Page 6: ...erta en una armadura PLANIFICACI N DE LA INSTALACI N TAPA DE TECHO CODO REDONDO DE 4 PULG CONDUCTO REDONDO DE 4 PULG TAPA DE PARED Se compran por separado El ventilador funcionar con m s eficacia y me...

Page 7: ...ones de los conductos para fijarlas y hacerlas herm ticas al aire 3 Acople el conectador del regulador de tiro conducto Conecte a presi n el conectador del regulador de tiro conducto en la cubierta As...

Page 8: ...pecificar el n mero de la pieza no el n mero de la clave 8 Empuje la rejilla contra el cielo raso 10 Instale las bombillas Se incluye una bombilla fluorescente Compre una bombilla incandescente para l...