MOUNTING THE HOUSING

1. 

Refer to Figure 3.

Insert mounting brackets at each end of

housing.

2. Place long side of housing parallel to ceiling joist. Position housing

in desired location. Make sure housing flange is even with the
planned finished ceiling.

3. Use screws or nails (not provided) to secure mounting brackets to

ceiling joists.

4. 

Refer to Figure 1.

Use 4" round duct to discharge the ventilator to

the outside.

IMPORTANT: Be sure nothing obstructs the discharge of

the ventilator. Make sure that insulation does not get into the
duct work or into the fan.

WIRING

Refer to Figure 2.

1. Run 120v AC house power wiring (with ground) through switch box

to junction box in ventilator housing.

2. Remove ventilator junction box cover.
3. Connect white supply common lead to white leads from fan and

light receptacle. Connect black supply wire from fan switch to black
wire from fan receptacle. Connect black supply wire from light
switch to black wire from light receptacle. Connect supply ground
wire to green ground screw.

4. Replace junction box cover.

NOTE: BE SURE VENTILATOR AND SWITCH ARE PROPERLY

GROUNDED. ALL WIRING MUST COMPLY WITH LOCAL
ELECTRICAL CODES.

POWER/BLOWER UNIT INSTALLATION

1. Plug motor into socket in housing's junction box.
2. Position power unit over mounting screw in housing.
3. Slide unit forward using the guide on the blower housing to

engage opening in housing until mounting screw is seated in
narrow end of keyhole slot.

4. 

Refer to Figure 3.

Securely tighten screw.

INSTALLATION IN EXISTING CONSTRUCTION

Installing the ventilator in an existing house requires an

accessible area (attic crawl space) above the planned installation
location. Review “INSTALLATION IN A NEW CONSTRUCTION”
and follow all instructions which apply to your installation.

Location –

locate ventilator parallel to a ceiling joist.

Wiring and Ducting –

plan ducting and wiring before proceeding

with installation.

Refer to Figure 2 for wiring and Figure 1 for

ducting. CAUTION: Check area above planned installation to
be sure that the ducting can be installed, wiring can be run to
the planned location and that wiring or other obstructions will
not interfere with the installation.

INSTALLATION FROM ACCESSIBLE AREA
ABOVE

1. From below, drill a small hole in ceiling at the planned location.

Stick clothes hanger through hole to help locate it.

2. Locate hole in attic or crawl space.
3. In attic or crawl space, mark ceiling for cutout by using the

housing as a template. The long side of cutout must be parallel 
to ceiling joist.

4. Make cutout along marked line.

NOTE: If ceiling is plaster, cutout should be made from

below to avoid chipping plaster.

5. Install housing, connect wiring and ducting, install power

unit/blower assembly and install grille.

FIGURE 3

DISCHARGE OPENING

HOUSING

MOUNTING
BRACKET

MOUNTING SCREWS

MOUNTING SPRING

NOTCHED BOSS

POWER UNIT 

GRILLE

Summary of Contents for LS100L

Page 1: ...o not damage electrical wiring and other hidden utilities D Ducted fans must always be vented to the outdoors E If this unit is to be installed over a tub or shower it must be marked as appropriate for the application and be connected to a GFCI Ground Fault Circuit Interrupter protected branch circuit F NEVER place a switch where it can be reached from a tub or shower Do not install in a ceiling i...

Page 2: ...guide on the blower housing to engage opening in housing until mounting screw is seated in narrow end of keyhole slot 4 Refer to Figure 3 Securely tighten screw INSTALLATION IN EXISTING CONSTRUCTION Installing the ventilator in an existing house requires an accessible area attic crawl space above the planned installation location Review INSTALLATION IN A NEW CONSTRUCTION and follow all instruction...

Page 3: ...d below or telephone 1 800 543 8687 b give the model number and part identification and c describe the nature of any defect in the product or part At the time of requesting warranty service you must present evidence of the original purchase date Date of Installation Builder or Installer Model No and Product Description IF YOU NEED ASSISTANCE OR SERVICE For the location of your nearest NuTone Indep...

Page 4: ...ÉLECTRIQUE OU DE BLESSURES RESPECTER CE QUI SUIT A Les travaux d installation et d électricité doivent être confiés à des personnes qualifiées conformément aux normes et aux codes en vigueur notamment en ce qui concerne les normes de protection contre les incendies B Pour éviter les retours d air les appareils de chauffage doivent avoir suffisamment d air pour assurer une combustion et une évacuat...

Page 5: ...ion à la vis de borne de terre verte 4 Replacer le couvercle de la boîte de jonction REMARQUE LE VENTILATEUR ET L INTERRUPTEUR DOIVENT ÊTRE MIS CORRECTEMENT À LA TERRE ET TOUS LES RACCORDS DOIVENT ÊTRE CONFORMES AUX CODES D ELECTRICITE LOCAUX POSE DE L ENSEMBLE MOTEUR VENTILATEUR 1 Brancher le moteur dans la douille de la boîte de jonction du boîtier 2 Placer le plaque de montage du moteur par des...

Page 6: ...ne au 1 800 543 3687 b fournir le numéro du modèle et la description de la pièce et c décrire la nature du défaut de la pièce ou du produit Au moment de la demande de service sous garantie vous devez fournir une preuve de la date d achat originale Date d installation Entrepreneur ou installateur N de modèle et description du produit POUR OBTENIR DE L ASSISTANCE OU DU SERVICE Pour connaître le Cent...

Page 7: ...Si la unidad se va a instalar sobre una bañera o ducha debe ser marcada de acuerdo a la aplicación y ser conectada a un circuito derivado protegido con fusible de seguridad a tierra GFCI F No coloque NUNCA un interruptor donde pueda ser alcanzado desde la bañera o ducha No lo instale en un techo aislado en un valor mayor de R40 Apropiado para ser utilizado con controles de la velocidad de estado s...

Page 8: ...a en el bastidor del soplador para encajar el agujero del bastidor hasta que el tornillo de montaje se asiente en el extremo estrecho de la ranura en ojo de cerradura 4 Refiérase a la Figura 3 Apriete el tornillo firmemente INSTALACION EN UNA CONSTRUCCION EXISTENTE La instalación del ventilador la luz de noche en una casa existente requiere un área pequeña accesible ático o sótano de pequeña altur...

Page 9: ... el número de modelo y la identificación de la parte y c describir la naturaleza de cualquier defecto en el producto o parte Al momento de solicitar el servicio por la garantía Ud debe presentar la evidencia de la fecha original de compra Fecha de instalación Constructor o instalado Nº de modelo y descripción del producto SI NECESITA ASISTENCIA O SERIVIVIO Para obtener la localización del Centro d...

Page 10: ...G HARDWARE LS80L LS100L 0506B 000 9 88958 GRILLE ASSEMBLY LS80L LS100L 88958 000 10 85046 SPRING 2 required LS80L LS100L 0431A 000 11 89156 DUCT COLLAR LS80L LS100L 89156 005 12 88954 POWER UNIT LS80L 88954 000 13 88955 POWER UNIT LS100L 88955 000 14 0701B GRILLE SPRING ASSEMBLY LS80L LS100L 0701B 000 15 84999 LENS LS80L LS100L 84999 000 16 88946 REFLECTOR ASSEMBLY not shown LS80L LS100L 88946 000...