MODELS BN100C • NT080C • NT100C

SUSPENDED CEILINGS

Housing hung with wires - 3-point mount.

N

EW

C

ONSTRUCTION

1.Choose the location for your fan in the ceiling. For best possible

performance, use the shortest possible duct run and a minimum
number of elbows.

2.Position mounting tabs against joist so that bottom edge of 

housing will be flush with finished ceiling.

Additional positioning feature for 5/8”, 1” & 1¼” thick ceiling 
material:
Holes in corners of housing are labeled with various ceiling 
material thicknesses. Position housing so bottom edge of 
joist is visible through a matched set of holes. The housing is 
now in the proper position for that ceiling material thickness.
Additional positioning feature for 1/2” thick ceiling material:
Bend two tabs, on side of housing, 90° outward. Lift housing 
until tabs contact underside of joist.

Mark the keyhole slot on both mounting tabs.

N

EW

C

ONSTRUCTION

(

CONT

D

)

3.Set housing aside and drive nails partially into joist at the top of 

both keyhole marks.

4.Hang housing from nails and pound nails tight. To ensure a 

noise-free mount, pound another nail through the top hole of 
each mounting tab.

1.Choose the location for your fan in the ceiling. For best possible

performance, use the shortest possible duct run and a minimum 
number of elbows.

2.In attic, position mounting brackets against joist. Trace outline of

housing on ceiling material.

3.Set housing aside and cut ceiling opening slightly larger than 

marked.

E

XISTING

C

ONSTRUCTION

MOUNTING

TAB

GRILLE

S

U

S

PENDED

CEILING MATERIAL

POWER

CABLE

4" ROUND

DUCT

HOU

S

ING

BH0011A

5/

8

1

1-1/4

BR000

3

BR0004

BOTTOM EDGE OF JOIST

TAB

TYPICAL INSTALLATIONS 

(

CONTINUED

)

INSTALL THE  HOUSING 

(

CONTINUED

)

INSTALL THE  HOUSING

Summary of Contents for BN100C

Page 1: ...be installed over a tub or shower it must be marked as appropriate for the application and be connected to a GFCI Ground Fault Circuit Interrupter protected branch circuit 8 Never place a switch wher...

Page 2: ...tabs on side of housing 90 outward Lift housing until tabs contact underside of joist Mark the keyhole slot on both mounting tabs NEW CONSTRUCTION CONT D 3 Set housing aside and drive nails partially...

Page 3: ...ctly to joists or framing 4 Place housing in opening so that its bottom edge is flush with finished ceiling Nail to joist through keyhole on both sides To ensure a noise free installation drive anothe...

Page 4: ...chase THERE ARE NO OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE During this one year period Broan NuTone C...

Page 5: ...e Installateur laisser ce manuel au propri taire Propri taire voir les directives sur l utilisation et l entretien la page 8 SOLIVES DE 24 po CENTRE CENTRE Bo tier mont sur un cadre additionnel AVERTI...

Page 6: ...suppl mentaire au positionnement pour le mat riau de plafond de 1 2 po d paisseur Plier les deux pattes de chaque c t du bo tier 90 vers l ext rieur Soulever le bo tier jusqu ce que les pattes entren...

Page 7: ...n forme de serrure des deux c t s Pour assurer un fonctionnement silencieux enfoncer un clou dans le trou sup rieur de chaque bride de montage CONSTRUCTION EXISTANTE 1 C bler l appareil en suivant le...

Page 8: ...la main d uvre pour une p riode de un an compter de la date d achat originale IL N Y A PAS D AUTRES GARANTIES EXPRIM ES OU IMPLICITES INCLUANT MAIS NON PAS LIMIT AUX GARANTIES IMPLICITES POUR FIN DE C...

Reviews: