background image

Page 1

WARNING

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR
INJURY TO PERSONS, OBSERVE THE FOLLOWING:

1. Use this unit only in the manner intended by the manufacturer. 

If you have questions, contact the manufacturer at the address 
or telephone number listed in the warranty.

2. Before servicing or cleaning unit, switch power off at service 

panel and lock the service disconnecting means to prevent 
power from being switched on accidentally. When the service 
disconnecting means cannot be locked, securely fasten a 
prominent warning device, such as a tag, to the service panel.

3. Installation work and electrical wiring must be done by a qualified

person(s) in accordance with all applicable codes and standards,
including fire-rated construction codes and standards.

4. Sufficient air is needed for proper combustion and exhausting

of gases through the flue (chimney) of fuel burning equipment to
prevent backdrafting. Follow the heating equipment manufacturer’s
guideline and safety standards such as those published by the
National Fire Protection Association (NFPA), and the American
Society for Heating,Refrigeration and Air Conditioning 
Engineers (ASHRAE), and the local code authorities.

5. When cutting or drilling into wall or ceiling, do not damage 

electrical wiring and other hidden utilities.

READ AND SAVE THESE INSTRUCTIONS

WARNING

6. Ducted fans must always be vented to the outdoors.
7. If this unit is to be installed over a tub or shower, it must be 

marked as appropriate for the application and be connected to 
a GFCI (Ground Fault Circuit Interrupter) - protected branch circuit.

8. Never place a switch where it can be reached from a tub or 

shower.

9. This unit must be grounded.
10.When applicable local regulations comprise more restrictive 

installation and/or certification requirements, the aforementioned
requirements prevail on those of this document and the 
installer agrees to conform to these at his own expenses.

11.When performing installation, servicing or cleaning this unit, it

is recommended to wear safety glasses and gloves.

CAUTION

1.For general ventilating use only. Do not use to exhaust 

hazardous or explosive materials and vapors.

2.To avoid motor bearing damage and noisy and/or unbalanced 

impellers, keep drywall spray, construction dust, etc. off power unit.

3.Please read specification label on product for further information

and requirements.

Installer: Leave this manual with the homeowner.

Homeowner: Use and Care information on page 4.

30042353C

!

HOU

S

ING

CEILING

JOI

S

T

MOUNTING TAB

S

GRILLE

CEILING

MATERIAL

POWER CABLE

4" ROUND

DUCT

ADDITIONAL

FRAMING

BH0010A

TYPICAL INSTALLATIONS

TYPICAL INSTALLATIONS

16”-ON-CENTER CEILING JOISTS

Housing mounted directly to joist.

24”-ON-CENTER CEILING JOISTS

Housing mounted additional framing.

HOU

S

ING

CEILING

JOI

S

T

MOUNTING TAB

S

GRILLE

CEILING

MATERIAL

POWER CABLE

BH0009A

MODELS BN100C • NT080C • NT100C

MODELS BN100C, NT080C 
& NT100C VENTILATION FANS

REGISTER YOUR PRODUCT ONLINE AT

• For Broan BN100C: www.broan.ca

• For NuTone NT080C or NT100C: www.nutone.ca

Summary of Contents for BN100C

Page 1: ...be installed over a tub or shower it must be marked as appropriate for the application and be connected to a GFCI Ground Fault Circuit Interrupter protected branch circuit 8 Never place a switch wher...

Page 2: ...tabs on side of housing 90 outward Lift housing until tabs contact underside of joist Mark the keyhole slot on both mounting tabs NEW CONSTRUCTION CONT D 3 Set housing aside and drive nails partially...

Page 3: ...ctly to joists or framing 4 Place housing in opening so that its bottom edge is flush with finished ceiling Nail to joist through keyhole on both sides To ensure a noise free installation drive anothe...

Page 4: ...chase THERE ARE NO OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE During this one year period Broan NuTone C...

Page 5: ...e Installateur laisser ce manuel au propri taire Propri taire voir les directives sur l utilisation et l entretien la page 8 SOLIVES DE 24 po CENTRE CENTRE Bo tier mont sur un cadre additionnel AVERTI...

Page 6: ...suppl mentaire au positionnement pour le mat riau de plafond de 1 2 po d paisseur Plier les deux pattes de chaque c t du bo tier 90 vers l ext rieur Soulever le bo tier jusqu ce que les pattes entren...

Page 7: ...n forme de serrure des deux c t s Pour assurer un fonctionnement silencieux enfoncer un clou dans le trou sup rieur de chaque bride de montage CONSTRUCTION EXISTANTE 1 C bler l appareil en suivant le...

Page 8: ...la main d uvre pour une p riode de un an compter de la date d achat originale IL N Y A PAS D AUTRES GARANTIES EXPRIM ES OU IMPLICITES INCLUANT MAIS NON PAS LIMIT AUX GARANTIES IMPLICITES POUR FIN DE C...

Reviews: