PLANNING DUCTWORK AND WIRING

DUCTWORK

1. Use 4" round duct.
2. Plan to run duct from the fan's discharge opening to the
outside. For best fan performance, make duct run as short as
possible and use minimum number of elbows.
3. Use optional NuTone ducting accessories as needed (refer
to NuTone's catalog for a complete listing of optional
accessories).

WIRING

Plan to run 120vAC house wiring (with ground) from a

power source, through a standard wall switch or an optional
NuTone double FAN/LIGHT switch, to the junction box in the
Fan-Light's housing.

INSTALLATION IN A NEW
CONSTRUCTION SITE

PREPARATION

1. Unplug the power unit.
2. 

Refer to Figure 1.

Remove power unit/blower assembly

from the housing. Remove screw and pull power unit
assembly tabs out of slots in housing. Set unit aside until
needed.

3. Remove one of the wiring knockouts from housing.

MOUNTING THE HOUSING

USING SIDE MOUNTING TABS

Refer to Figure 2.

1. Locate housing next to ceiling joist.
2. Use wood screws (not provided) to loosely attach housing

to ceiling joist through keyhole slots in mounting tabs.

3. Adjust housing so that it will be flush with the finished

ceiling.

4. When housing is properly adjusted, tighten screws in slots.

USING HANGER BARS

(Hanger bars sold separately, order model HB4)
Refer to Figure 3.

1. Insert hanger bars in slots provided in housing.
2. Locate fan housing between ceiling joists so that bottom of

fan housing is even with the planned finished ceiling.

3. Use screws or nails to secure mounting brackets to ceiling

joists.

INSTALLING DUCTWORK

1. 

Refer to Figure 1.

Place duct collar over flanges at

discharge opening of fan. Secure collar by snapping tabs
into slots in flanges.

2. 

Refer to Figure 4.

Run 4" round duct from outside to fan's

discharge opening.

3. Connect duct to duct collar.

FIGURE 2

FIGURE 3

FIGURE 4

WIRING
KNOCKOUTS

MOUNTING
TABS

ROOF CAP

90° ELBOW

4" DIAMETER
DUCT

WALL CAP

HANGER BARS

(SOLD SEPARATELY)

Summary of Contents for 769RF

Page 1: ...ccordance with all applicable codes and standards including fire rated construction B Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning eq...

Page 2: ...NG THE HOUSING USING SIDE MOUNTING TABS Refer to Figure 2 1 Locate housing next to ceiling joist 2 Use wood screws not provided to loosely attach housing to ceiling joist through keyhole slots in moun...

Page 3: ...BLOWER UNIT INSTALLATION Refer to Figure 7 1 Place power blower unit into housing so that mounting plate s tabs insert into slots in housing 2 Press other end of mounting plate down until it is firml...

Page 4: ...PRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE During this one year period NuTone will at its option repair or replace without...

Page 5: ...EEL 769RF 82403 000 4 87549 REFLECTOR ASSEMBLY 769RF 87549 000 5 30652 DUCT ADAPTER ASSEMBLY 769RF 30652 000 6 85315 GRILLE AND LENS ASSEMBLY 769RF 85315 000 7 16133 WING NUT 769RF 16133 000 8 10034 F...

Page 6: ...s ou des vapeurs INSTRUCTIONS D INSTALLATION MISE EN GARDE POUR REDUIRE LE RISQUE D INCENDIE D ELECTROCUTION OU DE BLESSURE PHYSIQUE RESPECTEZ LES OBSERVATIONS SUIVANTES A L installation et les c blag...

Page 7: ...f rer la figure 2 1 Placez le bo tier c t de la solive du plafond 2 Utilisez des visses en bois non fournies pour attacher le bo tier l chement la solive du plafond travers les fentes dans les pattes...

Page 8: ...rer la figure 7 1 Placez l unit de courant ventilateur dans le bo tier pour monter les pattes de la plaque dans les fentes du bo tier 2 Poussez l autre extr mit de la plaque de montage vers le bas ju...

Page 9: ...pour une p riode d un 1 an compter de la date d achat AUCUNE AUTRE GARANTIE IMPLICITE OU EXPRESSE N EST DONN E Y COMPRIS MAIS SANS S Y LIMITER GARANTIE DE MARCHANDIBILIT OU D ADAPTATION UN USAGE PARTI...

Page 10: ...RF 82403 000 4 87549 ASSEMBLAGE DU REFLECTEUR 769RF 87549 000 5 30652 ASSEMBLAGE DE L ADAPTATEUR DE LA GAINE 769RF 30652 000 6 85315 ASSEMBLAGE GRILLE ET LENTILLE 769RF 85315 000 7 16133 ECROU A AILET...

Reviews: