OPI_TOP LIFT TSK 8000_V3.2_EN
25
Value is placed on long lifetimes and safety in the
development and production of Nussbaum prod-
ucts. To guarantee the safety of the operator, prod-
uct reliability, low running costs, keep the warranty
and also the long-lifetime of the product, proper
set up and operation is just as important as regular
maintenance and sufficient care.
Our platforms fulfil TUV, BG and CE certifications
and exceed all safety standards of the countries
we supply to. For example, European regulations re
-
quire a service by qualified experts every 12 months
of work of the platform. To guarantee the largest
possible availability and functional capacity of the
lift system, ensure the list of any cleaning, care and
maintenance work is done.
After first commissioning the lift is to be serviced at
regular intervals of a maximum of one year by an
authorised person according to the following plan.
For intensive operation and higher degree of con-
tamination shorten the service interval.
The complete function of the lift is to be observed
during daily use. Customer service must be in-
formed of any malfunctions.
7.1 Maintenance plan
i
Before beginning service, disconnect from power. The work area around the lift is to be secured against
unauthorised use.
Visual
inspection
Spray
Oil
Lubricate
Clean with
compressed
air
Clean
Inspect
Time frame
Maintenance
type position
Maintenance plan
Daily
1
12
11
10
9
8
7 6 5
4
3
2
365 x / 12
Lift owner /
employer
Model and information signs, labels, brief operating
instructions, safety stickers and warning information
are to be cleaned and exchanged if damaged.
Daily
1
12
11
10
9
8
7 6 5
4
3
2
365 x / 12
Lift owner /
employer
The rubber acceptance plate is to be checked for
wear and replaced if necessary.
(only for the version with lifting arms)
Annually
1
12
11
10
9
8
7 6 5
4
3
2
1 x / 12
Trained ser-
vice personnel
Check the lifting arm block and gear for wear. Ex
-
change if there is visible damage.
(only for the version with lifting arms)
Annually
1
12
11
10
9
8
7 6 5
4
3
2
1 x / 12
Trained ser-
vice personnel
Lifting arm booms, lifting arm bolts, carrier plate
threaded bolts are to be checked for ease of running.
If required, lightly grease with multi-purpose grease.
Do not over-lubricate.
(only for the version with lifting arms)
Summary of Contents for TSK 8000
Page 2: ...2 OPI_TOP LIFT TSK 8000_V3 2_EN...
Page 4: ......
Page 9: ...OPI_TOP LIFT TSK 8000_V3 2_EN 9...
Page 20: ...20 OPI_TOP LIFT TSK 8000_V3 2_EN...
Page 44: ...44 OPI_TOP LIFT TSK 8000_V3 2_EN...
Page 45: ...TOP LIFT TSK 8000 Serial No Made in Germany Spare parts list...