EDIT PARAMETERS
Use the
and
keys in the welding menu to select a parameter. The selected parameter is
indicated by the
icon in front of it.
Editing of Burnback Time:
Burnback time is the time between stopping the welding wire and cutting the welding current. During
this process, the welding wire continues to burn and prevents sticking. To change this parameter,
select the burnback time and enter a value between 1 and 9 and press the
key.
Editing the Number of Welding Wires:
The number of welding wires must be entered for the correct voltage value. To select the number of
wires, enter a value between 1 and 2 and press the
key.
Editing Wire Diameter:
Wire diameter must be selected for the correct voltage value. Select the wire diameter, then press the
key to view the predefined wire diameters. Select one using the
and
keys and
press the
key to accept the selection.
Editing Hot Start Rate:
The hot start rate is a current rate added to the short circuit current limitation at the start of the
weld. To change this parameter, select the hot start rate menu, enter a value between 1 and 9 and
press the
key.
Editing Hot Start Time:
The warm start time is related to the process in which the warm start is applied. To change this
parameter, select Hotstart Time, enter a value between 0 and 9 and press the
key.