19
T 01460 68600
Changing the Floor Tool Blades
2
4
3
5
1
Floor Tool Overview
1. Retaining knobs x 4
2. Front blade (slotted)
3. Blade carrier
4. Rear blade
5. Floor tool main body
ALWAYS ENSURE THAT THE BATTERY IS DISCONNECTED
PRIOR TO ANY MAINTENANCE
!
!
NOTE: The blades are designed to be
reversible, thus extending their useful
working life.
To change the floor tool, firstly swing the
floor-tool clear of the machine. Undo the
two floor-tool retaining knobs (Fig.A).
Pull the floor tool away from the machine
(Fig.B).
Refit the blade holder, retain using the two outer knobs (Fig.46).
Ensure the slotted blade goes to the front of the floor-tool (Fig.47).
Note:
The blades are designed to be reversible, thus extending their useful working life.
Note: The blades are designed to be reversible, thus extending their useful working life.
Refit the floor-tool using the two central knobs to the floor-tool. Refer to Page 9 for fitting
instructions.
A
1
2
3
B
Replace the Squeegee blades using
(903531) replacement blade set (Fig.3),
fitting the blades on to the moulded
location lugs
.
Remove the blade holder (Fig.2).
Unscrew the four knobs securing the
blade holder (Fig.1).
Refitting the Floor Tool Blades
Summary of Contents for TTB 1840G