44
English
Easy steam
PROBLEMS:
Below is a list of the solutions for some problems that may occur on the machine
over time.
9
- MAINTENANCE AND REPAIR
ANOMALIES
CAUSES
SOLUTIONS
1
WHEN THE MAIN SWITCH
IS TURNED OFF THE DIFFE-
RENTIAL BLOWS
- Extension cable excessi-
vely long
- Use a suitable extension ca-
ble
- Resistance insulated
- Replace resistance
2
THE GENERATOR PRESSURE
DOES NOT INCREASE
- Machine with lack of
water
- Check water quantity in
tanks
- Pressure gauge
- Check pressure gauge
- Resistance
- Check resistance
- Thermostat
- Check the thermostat
3
PUMP DOES NOT WORK
- Water tanks empty
- Fill up tanks
- does not load water
- Pump
- Replace pump
- Filter clogged
- Celan or replace fi
lter
- Water lacking pilot light is
always on
- Pump
- Replace pump
- Lack of water in tank
- Fill up tank
- Water electrovalve
- Replace electrovalve
- does not starts
- Level probe
- Remove any scaling or al-
gae from probe
4
SAFETY VALVE OPENS RE-
PEATEDLY
- water is loaded continuo-
usly
- Boiler water level probe
- Remove any scaling or al-
gae from probe
- Pressure gauge
- Replace pressure gauge
and check that the hydrau-
lic circuit is free from sca-
ling
- Safety valve
- Replace safety valve
5
STEAM IS NOT SUPPLIED
- Electrovalve coil cut off
- Replace coil
- Electrovalve body dirty
- Replace electrovalve body