IMPORTANT USER INFORMATION

Before use operators shall be provided with information, instruction and training for the use of the 

machine and the substances for which it is to be used, including the safe method of disposing of 

material collected.

The dust container has to be emptied when necessary, but also after every time used. 

This vacuum cleaner has a lamp that illuminates when air velocity drops below a preset level, which 

indicates that the bag must be changed.

This machine is not suitable for connection with dust generating machines.

All

 fi lters including the bag must be undamaged and in correct position before this machine can be used 

safely.

CAUTION: This machine is for dry use only and is not to be used or stored outdoors in wet conditions.

Do not pick up glowing embers or dust or any other ignition hazard

Do not use the power cable as a method of moving the machine.

WARNING:

1. 

This machine must only be operated by suitably trained and authorised personnel.

2. 

This machine or its accessories must not be modifi ed.

3. 

The machine must not be stored or used in a wet environment.

4. 

Do not allow the dust collection bag (NVM-2BH) to become so full as to reduce the eff ective  

 

pick-up of the vacuum. (Lamp will illuminate at preset air velocity levels < 16 m/s).

5. 

Only use the dust collection bag (NVM-2BH) once.

6. 

This machine must only be repaired by suitably trained and authorised personnel.

7. 

Only use genuine Numatic International Ltd spare parts, for repairs.

8. 

This machine must not be installed as a fi xed extraction system or run unattended.

9. 

Do not re-use the essential fi lter element after removal out of the machine.

Operators should observe any safety regulations appropriate to materials being handled. 

This machine is for dry use only.

PREPARATION FOR USE

Unpack and identify each item of equipment from the delivery note.

Check that the details given match the information on the “rating plate” mounted on the head assembly.

Installation / Removal / Disposal of the dust bag.

The dust bag holding the dust and debris must be removed and renewed by authorised personnel only, 

wearing appropriate personnel protective equipment, in a specifi ed de-contamination area. 

Never operate without the full fi ltration system in place.

Process of disposal: 

Disconnect the hose, fi t the Dust Cap on the Hose Flange, un-clip the bottom two Toggle Clamps. 

Remove the cloth fi lter (A) in the Drum. Remove the dust bag from the Hose Flange inside the drum and 

seal the Dust Bag hole. Place the Dust Bag inside an impervious plastic bag and seal the bag. 

Dispose of the plastic bag, depending on contamination, in an appropriate manner.

Summary of Contents for HZ 190

Page 1: ...ION Read the Instructions before using the machine CAUTION Read the Instructions before using the machine HZ 190 200 250 350 370 HZ 190 200 250 350 370 450 570 750 900 450 570 750 900 HZD 450 570 750...

Page 2: ...2BH HZ 450 Kit AA19 NVM 3AH HZ 570 Kit AA19 NVM 3BH NVM 3BM HZ 750 Kit AA20 NVM 4BH NVM 4BM HZ 900 Kit AA20 NVM 4BH NVM 4BM HZD 450 Kit BB19 NVM 3AH HZD 570 Kit BB19 NVM 3BH NVM 3BM HZD 750 Kit BB20...

Page 3: ...3 HZ Kits 902242 AA18 350 370 Type 902243 AA19 470 570 Type 902244 AA20 750 900 Type 607470 AA17 190 200 250 Type...

Page 4: ...4 HZ 350 HZ 450 HZ 750 HZD 450 HZD 750 4 x 10mm X 4 Handle Assembly 350 450 750 Handle Assembly 350 450 750...

Page 5: ...5 Handle Assembly 900 Handle Assembly 900 X 4 X 4...

Page 6: ...6 Fitting the bag Fitting the bag...

Page 7: ...7 I 0 Fitting the hose Fitting the air seperator Fitting the hose Fitting the air seperator...

Page 8: ...8 Moving the machine Moving the machine 370 Drum only Tool Tidy 370 Drum only Tool Tidy...

Page 9: ...9 A A A B B B Changing the bag cleaning the filter Changing the bag cleaning the filter REF Page 15 REF Page 15...

Page 10: ...900 Classification TYPE H TYPE H Voltage 115 120 220 240V 115 120 220 240V Frequency 50 60Hz 50 60Hz Power rating 1000 W 1000 W x 2 Sound Pressure LpA Uncertainty KpA 65 dB A 0 5 dB 67 dB A 0 5 dB Lo...

Page 11: ...11 1 2 3 4 5 6 7 8 Changing the cable Changing the cable...

Page 12: ...ntries Do not dispose of vacuum cleaner into household waste According to the European Directive 2012 19 EU on waste electrical and electronic equipment and its incorporation into national law Vacuum...

Page 13: ...intended for commercial use for example in hotels schools hospitals factories shops o ces This product complies with the requirements of clause 20 of EN 60335 2 69 Stability and Mechanical Hazards DO...

Page 14: ...Lamp will illuminate at preset air velocity levels 16 m s 5 Only use the dust collection bag NVM 2BH once 6 This machine must only be repaired by suitably trained and authorised personnel 7 Only use...

Page 15: ...sonably practicable without causing risk to maintenance sta and others Suitable precautions include decontamination before dismantling provision for local filtered exhaust ventilation where the machin...

Page 16: ...1000 173 119 260 2500 14 15 385x365x845 HZ 370 1000 173 119 260 2500 15 11 355x355x570 HZ 450 1000 173 119 260 2500 20 26 5 510x500x940 HZ 570 1000 173 119 260 2500 23 18 415x415x746 HZ 750 1000 173...

Page 17: ...MicroTex 12 Filter 901647 Bottom filter for HZ machines 604411 MicroTex 14 Filter 901652 filter for all HZD machines 604151 Air Seperator 604015 NVM 1CH HepaFlo Bags Pack of 10 604017 NVM 3BH HepaFlo...

Page 18: ...LD STEEL CHASSIS ASSEMBLY 501016 HZ 450 HEAVY DUTY FIXED MILD STEEL CHASSIS ASSEMBLY 501017 HZ 750 1000 HEAVY DUTY FIXED MILD STEEL CHASSIS ASSEMBLY Cables Simplex Duplex 236010 10 0m X 1 mm2 X 3 CORE...

Page 19: ...19 HZ 12 14 inch Simplex WD 0235 A04...

Page 20: ...20 14 inch Metal 3 core WD 0229 A05...

Page 21: ...21 14 inch Metal 3 core 120 V WD 0264 A03...

Page 22: ...22...

Page 23: ...opria responsabilit che il prodotto di cui sopra conforme alle seguenti direttive e norme LT Mes Numatic parei kiu viena ali kos atsakomyb s kad pirmiau min tas produktas atitinka ias direktyvas ir st...

Page 24: ...umatic International Pty Ltd 16th Pharmaceutical Roads Midrand Gauteng SOUTH AFRICA 1685 Tel 0861 686 284 www numatic co za Numatic International Schweiz AG Sihlbruggstrasse 3A 6340 Baar SCHWEIZ Tel 0...

Reviews: