Page 28
If an error is detected, an error screen will alternate with the main display screen every few seconds, and the
LED
light will be red.
During an error condition, the unit continues to monitor the flow meter and update the remaining capacity.
Once an error condition is corrected, the unit returns to the operating status it was in prior to the error, and
regeneration resumes according to normal programming. If an error is cleared by reprogramming the unit in
the Master Programming Mode, the volume remaining may be reset to the full unit capacity (as though it had
just regenerated). If an error is present, a regeneration can only occur manually by pressing and holding the
Extra Cycle button for 5 seconds. If the unit was in regeneration when the error occurred, it will complete the
regeneration cycle and go into service.
When the problem is corrected, and the error no longer displays (it may take several seconds for the unit to stop
displaying the error message), the unit will return to normal operation. The
LED light
will no longer be
red
, and
will turn
Green
if the unit is regenerating, or
Blue
if the unit is in service.
Problem
Correction
A. Flashing/blinking display
A. Power outage has occurred. Either wait 5 minutes for
blinking to stop, or press any key on the keypad.
B. Unit not responding after going into
regeneration
B. Verify the unit is configured correctly (ex: wiring valve
type). Perform a Master Reset by holding the Shift button and
cycling power. Check and verify the choices selected in Master
Programming Mode.
C. Unit displays “ERROR CODE: REPLACE
UNIT” (corrupted UAP)
C. Contact your local water treatment professional.
Error
Code
Display Message
Correction
01
ERROR CODE:
PROGRAM UNIT
Go through all screens in Master Programming Mode.
02
ERROR CODE:
PROGRAM UNIT
Go through all screens in Master Programming Mode.
03
ERROR CODE:
SERVICE UNIT
Perform a Master Reset by holding the Shift button and cycling power. Go through
all screens in Master Programming Mode. Manually initiate a regeneration cycle
by pressing the Extra Cycle button for 5 seconds.
04
ERROR CODE:
SERVICE UNIT
Perform a Master Reset by holding the Shift button and cycling power. Go through
all screens in Master Programming Mode. Manually initiate a regeneration cycle
by pressing the Extra Cycle button for 5 seconds.
05
ERROR CODE:
SERVICE UNIT
Call your local water treatment professional as soon as possible. Leave the unit
running (do not unplug).
NOTE: If the above corrections do not work, please contact your local water treatment professional.
Error Display Screen Examples
Troubleshooting - Timer
Summary of Contents for 7000XTR
Page 21: ...Page 21 Notes ...
Page 22: ...Page 22 Power Head Assembly 61501 7000XT_REVA ...
Page 34: ...Page 34 Brine Tank Refill Position 40988_REVA 41121_REVA Water Conditioner Flow Diagrams ...
Page 38: ...Page 38 Dimensional Drawings 61500 7000XTR LNE_REVA ...
Page 39: ...Page 39 Meter Flow Data TR18753 Softener TR18688 Filter 41140 02_REVA ...
Page 40: ...Page 40 Injector Flow Data TR18755_REVB ...
Page 41: ...Page 41 Notes ...
Page 42: ...Page 42 Notes ...
Page 43: ...Page 43 Notes ...
Page 44: ...P N 42484 Rev A ...