Installation Manual

Remove temporary cross brace when cement 
has dried.  Fit the outer grille (note grille blades 
sloping down to shed water).

Spacer

Wall 

Fixing

Plate

Interior

Grille

Outside

Grille

Fit the inside grille to the fanplate, locating grille 
over the top lip before engaging screws.

11 

14 

15 

16 

17 

12 

13 

Removing Electrical Cover

Fitting Inner Grille

Fitting Outer Grille

Thin Wall Installation

Weather Terminal Installation

Bringing Cable Through Fan Plate

Assembling Fan

Release the electrical cover from the fan plate.

Bring the cable through the fan plate.

Assemble the fan plate to the inside sleeve.

IMPORTANT

During shutter operation of XS fans there will be a short delay on 

start-up and shut down of approximately 40 seconds, this is normal.

3.1 Installing Ancillaries (Also see Section 

X

)

3.1.1 Thin Wall

This thin wall application is best covered using a Window Kit. Drawing 
shows a Wall Fixing Plate fixed to the aperture by screws. The Window 
Kit clamps together either side of the Wall Fixing Plate.

3.1.2 Weather Terminal

This thin wall application is best covered using a Window Kit. Drawing 
shows a Wall Fixing Plate fixed to the aperture by screws. The Window 
Kit clamps together either side of the Wall Fixing Plate.

Summary of Contents for XS12WA

Page 1: ...by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard Precautions must be taken to avoid the back flow of gases into the room from the open flue of gas or ot...

Page 2: ...rated via the optional XS MFC remote controller allowing supply or extract variable speed and automatic or manual switching of several fans if desired 2 2 Sensors Sensors are available as remote units...

Page 3: ...support the other end INSIDE OUTSIDE Install the sleeve at a slight angle lower to outside IMPORTANT When fitting the sleeve introduce a slight downward slope to the outside to encourage any water to...

Page 4: ...e Assembling Fan Release the electrical cover from the fan plate Bring the cable through the fan plate Assemble the fan plate to the inside sleeve IMPORTANT During shutter operation of XS fans there w...

Page 5: ...ed control This avoids the possibility of one fan if speed controlled at a lower flow rate being stalled by the other fan s Adequate make up air provision sufficient to provide ventilation in accordan...

Page 6: ...5 L4 L3 L2 L1 N L4 L3 L2 L1 N L1 N Double pole isolator Fuse max 3 amp L N XS Fan unit with integral sensor Required if using integral Timer mains supply Remote switch may be set On Off Forward Revers...

Page 7: ...ors Optional The XS MFC Multi Fan Control provides supply or extract variable speed and automatic or manual switching of several fans if desired see note below The control is best mounted approx 1 5m...

Page 8: ...the prepared wall 37 Mounting Backplate 5 0 ANCILLARIES 5 1 Weather Terminal Used for exposed site wall installations comprising one weather terminal manufactured from HIPS Order Code XS WT6 Dimensio...

Page 9: ...0 END OF LIFE AND RECYCLING Where possible Nuaire use components which can be largely recycled when the product reaches its end of life Fans motors controls actuators cabling and other electrical comp...

Page 10: ...10 18 03 20 Document Number 671051 Nuaire Western Industrial Estate Caerphilly CF83 1NA nuaire co uk XS WA Installation Manual NOTES...

Page 11: ...11 18 03 20 Document Number 671051 Nuaire Western Industrial Estate Caerphilly CF83 1NA nuaire co uk XS WA Installation Manual NOTES...

Page 12: ...12 18 03 20 Document Number 671051 Nuaire Western Industrial Estate Caerphilly CF83 1NA nuaire co uk XS WA Installation Manual NOTES...

Reviews: